5975-12-167-8610

LOCKNUT,ELECTRICAL CONDUIT


5975-12-167-8610 (5975121678610, 121678610)
Part Numbers (34 listings): 2091151 | 52003530 | 6000169 | 216M | 420/16 | 5VB4223 | MSGMM-P16 | 8016 | 07911031255 | 08040916 | Q314162116 | 07.91103-1255 | 7-608-0354 | 62610044 | 169/MSPG16 | 19-132300-11053 | 08.040916 | B95129 | 07510307024 | 253952 | 91133016 | 046320016901 | 0158019 | SM16 | DZ0158019 | 200353 | W4621888 | 8.12.011 | 8.12.011.00 | DIN46320-M-PG16-MS | SM-16 | MPG16-DIN46320-MS | DIN46320-MPG16-MS | MPG16DIN46320MS |
Summary

FSG 59 / FSC 5975

DEMIL:

DEMIL INT:

HMIC:

Date Created: 26 Jan 1977

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5975-12-167-8610 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
20911513 - Design Control Reference2 - Production ItemOBO BETTERMANN GMBH & CO.  D0295      
520035303 - Design Control Reference2 - Production ItemLAPP, U.I. GMBH  D2030      
60001693 - Design Control Reference2 - Production ItemSCHLEMMER GMBH  D2412      
216M3 - Design Control Reference2 - Production ItemJACOB GMBH ELEKTROTECHNISCHE FABRIK  C3771      
420/163 - Design Control Reference2 - Production ItemNIEDAX GMBH & CO. KG  D9726      
5VB42233 - Design Control Reference2 - Production ItemCOM/NET HAMBURG GMBH  D1230      
MSGMM-P163 - Design Control Reference2 - Production ItemREIKU GMBH  C0290      
80163 - Design Control Reference2 - Production ItemAGRO  S3172      
079110312555 - Replaced / Discontinued2 - Production ItemMAN TRUCK & BUS AG  D3273    CAGE D3273  
080409165 - Replaced / Discontinued2 - Production ItemPHOENIX MECANO LTD  K0F62      
Q 314 162 1165 - Replaced / Discontinued2 - Production ItemRHEINMETALL AIR DEFENCE AG  S3092    CAGE S3092  
07.91103-12555 - Replaced / Discontinued2 - Production ItemMAN TRUCK & BUS AG  D3273    CAGE D3273  
7-608-03545 - Replaced / Discontinued2 - Production ItemBUCHER SCHOERLING GMBH  D0589    CAGE D0589  
626100445 - Replaced / Discontinued2 - Production ItemWEISS UMWELTTECHNIK GMBH  D0274      
169/MS PG165 - Replaced / Discontinued2 - Production ItemOBO BETTERMANN GMBH & CO.  D0295      
Q 314 162 1165 - Replaced / Discontinued2 - Production ItemRHEINMETALL SOLDIER ELECTRONICS GMB  C2463      
19-132300-110535 - Replaced / Discontinued2 - Production ItemBODAN-WERFT METALLBAU GMBH & CO. KG  D1141      
08.0409165 - Replaced / Discontinued2 - Production ItemROSE SYSTEMTECHNIK GMBH  C0242      
B951295 - Replaced / Discontinued2 - Production ItemMBDA UK LTD  K1020      
075103070245 - Replaced / Discontinued2 - Production ItemSTIHL, ANDREAS AG & CO.  D0103      
2539525 - Replaced / Discontinued2 - Production ItemBAE SYSTEMS (OPERATIONS) LTD  K0656    CAGE K0656  
911 330 165 - Replaced / Discontinued2 - Production ItemSALZGITTER MASCHINENBAU AG  C0957      
0463200169015 - Replaced / Discontinued2 - Production ItemDAIMLER AG  D8046    CAGE D8046  
01580195 - Replaced / Discontinued2 - Production ItemROHDE & SCHWARZ GMBH & CO. KG  D0894    CAGE D0894  
SM 165 - Replaced / Discontinued2 - Production ItemLAPP, U.I. GMBH  D2030      
DZ01580195 - Replaced / Discontinued9 - No Longer UsedROHDE & SCHWARZ GMBH & CO. KG  D0894    CAGE D0894  
2003535 - Replaced / Discontinued9 - No Longer UsedLAPP, U.I. GMBH  D2030      
W 4621 8885 - Replaced / Discontinued9 - No Longer UsedOERLIKON-BUEHRLE AG  S3118    CAGE S3118  
8.12.0115 - Replaced / Discontinued9 - No Longer UsedDSENERGY PROJECTS B.V.  H0068      
080409165 - Replaced / Discontinued9 - No Longer UsedROSE SYSTEMTECHNIK GMBH  C0242      
8.12.011.005 - Replaced / Discontinued9 - No Longer UsedDSENERGY PROJECTS B.V.  H0068      
DIN46320-M-PG16-MS5 - Replaced / Discontinued9 - No Longer UsedDIN DEUTSCHES INSTITUT FUER  D8286    CAGE D8286  
SM-165 - Replaced / Discontinued9 - No Longer UsedLAPP, U.I. GMBH  D2030      
MPG16-DIN46320-MS5 - Replaced / Discontinued9 - No Longer UsedDIN DEUTSCHES INSTITUT FUER  D8286    CAGE D8286  
DIN46320-MPG16-MS5 - Replaced / Discontinued9 - No Longer UsedDIN DEUTSCHES INSTITUT FUER  D8286    CAGE D8286  
MPG16DIN46320MS5 - Replaced / Discontinued9 - No Longer UsedDIN DEUTSCHES INSTITUT FUER  D8286    CAGE D8286  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5975-12-167-8610 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595975121678610228954326 Jan 1977
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5975

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Electrical Hardware and Supplies

121678610

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5975-12-167-8610

22895

Item Naming Code (INC_4080)

26 Jan 1977

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.


FLIS - SEG B - MOE RULE DATA | NSN 5975-12-167-8610 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
VE
WB
YB
YW
ZB
ZC
ZD
ZF
ZG
ZK
ZN
ZP
ZR
ZS
ZU
ZW
ZZ
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5975-12-167-8610 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
4522ZKD253952  K0656   CAGE/K0656
4522ZKD08040916  K0F62  
1522ZKDB95129  K1020  
4594ZND8.12.011  H0068  
4593ZND8.12.011.00  H0068  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

ZK

Reference Number Action Activity Code (RNAAC_2900)


United Kingdom

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

ZN

Reference Number Action Activity Code (RNAAC_2900)


Netherlands

3

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the technical documentation upon request.




Back to Top