Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
TDS-22013 | 3 - Design Control Reference | 2 - Production Item | MICROWAVE ENGINEERING CORPORATION | 06351 | ![]() |
990C063H03 | 7 - Vendor Item Drawing Reference | 2 - Production Item | NORTHROP GRUMMAN SYSTEMS CORPORATION | 18323 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5985 | 000930197 | A073A0 | 00305 | X | 1 | D | P | S | 0 | 3 Dec 1972 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item contains silver.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZG01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 5 | TX | D | TDS-22013 | 06351 | ![]() | |||||
3 | 7 | 2 | 5 | TX | D | 990C063H03 | 18323 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 4 Jun 1982 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TA | 723 | Z | 9 | A | H | Z | W | 063520 | Z | 49770 | WAVEGUIDE-IN-BOXES-CRATES |
Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609
Radio Parts, Batteries and Equipment, excluding Tubes Packed separately
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | 41 | 1 | AAA | 10.0 lbs | 0.333 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | EA | JC | X | DO | 00 | E | Q | U |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
MIL-DTL-17667, neutral wrapping paper
ASTM-D4727, domestic fiberboard used as pads, cells, die cuts or sleeves
As required to protect the item or elements of the package
Any suitable fiber box included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
STYL | Style Designator | STRAIGHT TYPE |
CTFD | Waveguide Length | 2.000 FEET NOMINAL |
AAGR | Cross-Sectional Shape Style | INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR |
CQHN | Waveguide Outside Width | 1.214 INCHES NOMINAL |
CRFH | Waveguide Inside Width | 1.120 INCHES NOMINAL |
CRLB | Waveguide Inside Height | 0.525 INCHES NOMINAL |
CSFC | Waveguide Outside Height | 0.630 INCHES NOMINAL |
FLEX | Flexibility | FLEXIBLE SINGLE TUBING SEGMENT |
AHRV | Tubing Wall Construction Style | SEAMLESS SINGLE TUBING SEGMENT |
MATT | Material | COPPER ALLOY SINGLE TUBING SEGMENT |
MATT | Material | ALUMINUM ALLOY 6061 ALL TUBING SEGMENT AND FLANGE |
SFTT | Surface Treatment | SILVER SINGLE TUBING SEGMENT ALL SURFACES |
SFTT | Surface Treatment | ANODIZE ALL FLANGE ALL SURFACES |
AHSF | Flange Quantity | 2 |
CTCJ | Flange Style | CONTACT, DOUBLE RIDGE TYPE ALL FLANGES |
AHSX | Flange Inside Width | 1.120 INCHES NOMINAL ALL FLANGES |
AHSY | Flange Inside Height | 0.525 INCHES NOMINAL ALL FLANGES |
AHSZ | Flange Outside Width | 1.969 INCHES NOMINAL ALL FLANGES |
AHTA | Flange Outside Height | 1.391 INCHES NOMINAL ALL FLANGES |
AHTD | Flange Depth | 0.250 INCHES NOMINAL ALL FLANGES |
CSQT | Flange Connecting Facility And Quantity | 4 UNTHREADED HOLE FIRST FLANGE FIRST CONNECTION FACILITY |
CSQT | Flange Connecting Facility And Quantity | 4 THREADED HOLE FIRST FLANGE SECOND CONNECTION FACILITY |
CSQT | Flange Connecting Facility And Quantity | 8 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
AHTN | Flange Connecting Hole Diameter | 0.148 INCHES NOMINAL FIRST FLANGE FIRST CONNECTION FACILITY |
AHTN | Flange Connecting Hole Diameter | 0.148 INCHES NOMINAL SECOND FLANGE ALL CONNECTION FACILITIES |
THSD | Thread Series Designator | UNC FIRST FLANGE SECOND CONNECTION FACILITY |
CQJX | Nominal Thread Size | 0.138 INCHES FIRST FLANGE SECOND CONNECTION FACILITY |
AAJD | Thread Class | 2B FIRST FLANGE SECOND CONNECTION FACILITY |
CMLP | Thread Quantity Per Inch | 32 FIRST FLANGE SECOND CONNECTION FACILITY |
AAJF | Thread Direction | RIGHT-HAND FIRST FLANGE SECOND CONNECTION FACILITY |
AHTX | Insertion Loss In Decibels | 0.20 |
AHTW | Voltage Standing Wave Ratio | 1.20 |
AGAV | End Item Identification | AN/ALQ-119(V) |
PRMT | Precious Material | SILVER |
PMLC | Precious Material And Location | OVERALL WAVEGUIDE SURFACES SILVER |