5985-00-137-8125

WAVEGUIDE ASSEMBLY


5985-00-137-8125 (5985001378125, 001378125)
Part Number (1 listing): 46067
Summary

FSG 59 / FSC 5985

DEMIL: D

DEMIL INT:

HMIC: P

Date Created: 21 Jul 1971

Unit Weight: 0.4 lbs

Unit Size: None

Unit Pack Cube: 0.040 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5985-00-137-8125 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
460673 - Design Control Reference2 - Production ItemNORTHROP GRUMMAN SYSTEMS CORPORATION  92755    CAGE 92755  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5985-00-137-8125 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595985001378125A073A000305X1DPA021 Jul 1971
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5985

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Antennas, Waveguides, and Related Equipment

001378125

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5985-00-137-8125

A073A0

Federal Item Identification Guide (FIIG_4065)

00305

Item Naming Code (INC_4080)

21 Jul 1971

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5985-00-137-8125 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
N9BNN9ND00ZKEKE1 Apr 2006
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

KE

Item Management Coding Activity (IMC_ACTY_2748)


Naval ICP, Philadelphia, PA 19111

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG C - REFERENCE NUMBER | NSN 5985-00-137-8125 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332ATXD46067  92755   CAGE/92755
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5985-00-137-8125 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX028 Jul 1971
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

28 Jul 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5985-00-137-8125 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
KE723Z9AHZW063520Z49770WAVEGUIDE-IN-BOXES-CRATES
Code Definitions

KE

Originating Activity Code (ORIG_ACTY_CD_4210)


Naval ICP, Philadelphia, PA 19111

723

Water Commodity Code (WRT_CMDTY_CD_9275)


Radio Parts, Batteries and Equipment, excluding Tubes Packed separately

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063520

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

49770

Uniform Freight Classification (UFC_CD_MODF_3040)

WAVEGUIDE-IN-BOXES-CRATES

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5985-00-137-8125 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSX71EA0
DSSMSX71EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

X

Acquisition Advice Code (AAC_2507)


SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.

7

Controlled Item Inventory Code (CIIC_2863)


Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5985-00-137-8125 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA0.4 lbs0.040 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
0000NAXD3DO00EQU
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.4 lbs

Unit Pack Weight (UP_WT_5153)

0.040 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

00

Wrapping Material Code (WRAP_MAT_CD_5163)


No requirement

NA

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

D3

Unit Container Code (UNIT_CTNR_CD_5166)


PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.

DO

Intermediate Container Code (INTMD_CTNR_CD_5167)


Any suitable fiber box included in this table may be used (see J.4.9.1).

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

E

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

U

Packing Requirement Code - For Minimal Packing (MINM_PK_RQ_CD_5172)


Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5985-00-137-8125 Submit RFQ
MRCDecoded RequirementClear Text Reply
AHTNFlange Connecting Hole Diameter0.169 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES
AHTDFlange Depth0.423 INCHES MINIMUM FIRST FLANGE AND 0.453 INCHES MAXIMUM FIRST FLANGE
AHTDFlange Depth0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE
CSQTFlange Connecting Facility And Quantity4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES
CSQTFlange Connecting Facility And Quantity4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES
AHTBFlange Inside Diameter1.406 INCHES MINIMUM FIRST FLANGE AND 1.437 INCHES MAXIMUM FIRST FLANGE
AHSYFlange Inside Height0.396 INCHES MINIMUM FIRST FLANGE AND 0.404 INCHES MAXIMUM FIRST FLANGE
AHSYFlange Inside Height0.503 INCHES MINIMUM SECOND FLANGE AND 0.506 INCHES MAXIMUM SECOND FLANGE
AHSXFlange Inside Width0.896 INCHES MINIMUM FIRST FLANGE AND 0.904 INCHES MAXIMUM FIRST FLANGE
AHSXFlange Inside Width1.003 INCHES MINIMUM SECOND FLANGE AND 1.006 INCHES MAXIMUM SECOND FLANGE
AHSFFlange Quantity2
CTCJFlange StyleCHOKE TYPE FIRST FLANGE
CTCJFlange StyleCOVER TYPE SECOND FLANGE
AHTAFlange Outside Height1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE
AHTAFlange Outside Height1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE
AHSZFlange Outside Width1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE
AHSZFlange Outside Width1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE
FLEXFlexibilityRIGID SINGLE TUBING SEGMENT
ZZZVFsc Application DataANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
MATTMaterialALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE
CQJXNominal Thread Size0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
STYLStyle DesignatorSTRAIGHT TYPE
AHTXInsertion Loss In Decibels0.05
AHRVTubing Wall Construction StyleSEAMLESS SINGLE TUBING SEGMENT
AAGRCross-Sectional Shape StyleINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
AHTWVoltage Standing Wave Ratio1.15
CRLBWaveguide Inside Height0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM
CRFHWaveguide Inside Width0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM
CSFCWaveguide Outside Height0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM
CQHNWaveguide Outside Width0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM
CTFDWaveguide Length2.250 INCHES NOMINAL
SFTTSurface TreatmentPAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
AAJDThread Class2B FIRST FLANGE ALL CONNECTION FACILITIES
AAJFThread DirectionRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
THSDThread Series DesignatorUNC FIRST FLANGE ALL CONNECTION FACILITIES


Back to Top
Back to Top