Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
123SCAV5709-1 | 3 - Design Control Reference | 2 - Production Item | NORTHROP GRUMMAN SYSTEMS CORPORATION | 26512 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5985 | 001722381 | A073A0 | 00305 | X | 4 | 3 | B | P | A | 27 Aug 1972 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZF01 | 1 Apr 1996 | |||||||||||||||||||||||||||||
N9BN | N9ND | 3 | B | Z | KE | KE | 1 Jul 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
Acquisition of this part is restricted to source(s) specified on "Source Control", "Altered Item" or "Selected Item" drawings/documents. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval ICP, Philadelphia, PA 19111
Naval ICP, Philadelphia, PA 19111
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | A | TX | D | 123SCAV5709-1 | 26512 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 2 Oct 1981 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KE | 723 | Z | 9 | A | H | Z | W | 063520 | Z | 49770 | WAVEGUIDE-IN-BOXES-CRATES |
Naval ICP, Philadelphia, PA 19111
Radio Parts, Batteries and Equipment, excluding Tubes Packed separately
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 41 | 1 | AAA | 2.0 lbs | 0.640 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | D3 | DO | 00 | E | Q | U |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
No requirement
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AAGR | Cross-Sectional Shape Style | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AHTN | Flange Connecting Hole Diameter | 0.169 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
AHTD | Flange Depth | 0.423 INCHES MINIMUM FIRST FLANGE AND 0.453 INCHES MAXIMUM FIRST FLANGE |
AHTD | Flange Depth | 0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
CSQT | Flange Connecting Facility And Quantity | 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
CSQT | Flange Connecting Facility And Quantity | 4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
AHSY | Flange Inside Height | 0.396 INCHES MINIMUM FIRST FLANGE AND 0.404 INCHES MAXIMUM FIRST FLANGE |
AHSY | Flange Inside Height | 0.503 INCHES MINIMUM SECOND FLANGE AND 0.506 INCHES MAXIMUM SECOND FLANGE |
AHSX | Flange Inside Width | 0.896 INCHES MINIMUM FIRST FLANGE AND 0.904 INCHES MAXIMUM FIRST FLANGE |
AHSX | Flange Inside Width | 1.003 INCHES MINIMUM SECOND FLANGE AND 1.006 INCHES MAXIMUM SECOND FLANGE |
AHSF | Flange Quantity | 2 |
CTCJ | Flange Style | CHOKE TYPE FIRST FLANGE |
AHTA | Flange Outside Height | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTA | Flange Outside Height | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHSZ | Flange Outside Width | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHSZ | Flange Outside Width | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
FLEX | Flexibility | RIGID SINGLE TUBING SEGMENT |
ZZZV | Fsc Application Data | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
MATT | Material | ALUMINUM ALL FLANGE |
CQJX | Nominal Thread Size | 0.138 INCHES FIRST FLANGE ALL CONNECTION FACILITIES |
AHRV | Tubing Wall Construction Style | SEAMLESS SINGLE TUBING SEGMENT |
CRLB | Waveguide Inside Height | 0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM |
CRFH | Waveguide Inside Width | 0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM |
CSFC | Waveguide Outside Height | 0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM |
CQHN | Waveguide Outside Width | 0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM |
SFTT | Surface Treatment | ANY ACCEPTABLE ALL FLANGE INSIDE SURFACES |
SFTT | Surface Treatment | ANY ACCEPTABLE ALL FLANGE OUTSIDE SURFACES |
AAJD | Thread Class | 2B FIRST FLANGE ALL CONNECTION FACILITIES |
AAJF | Thread Direction | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
CMLP | Thread Quantity Per Inch | 32 FIRST FLANGE ALL CONNECTION FACILITIES |
THSD | Thread Series Designator | UNC FIRST FLANGE ALL CONNECTION FACILITIES |