5985-00-296-1950

WAVEGUIDE ASSEMBLY


5985-00-296-1950 (5985002961950, 002961950)
Part Number (1 listing): 996562REVA
Summary

FSG 59 / FSC 5985

DEMIL: D

DEMIL INT:

HMIC: P

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5985-00-296-1950 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
996562REVA3 - Design Control Reference2 - Production ItemNAVAIR AND NAVSEA MANAGED  10001      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5985-00-296-1950 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595985002961950A073A000305XKDPA01 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5985

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Antennas, Waveguides, and Related Equipment

002961950

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5985-00-296-1950

A073A0

Federal Item Identification Guide (FIIG_4065)

00305

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5985-00-296-1950 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
YB011 Feb 1994
ZW011 Nov 1998
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5985-00-296-1950 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2TU02 Oct 1973
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

TU

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

2 Oct 1973

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5985-00-296-1950 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
P723Z9AHZW063520Z49770WAVEGUIDE-IN-BOXES-CRATES1
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


P

Less Than Carload (LCL_CD_2760)


77.5

723

Water Commodity Code (WRT_CMDTY_CD_9275)


Radio Parts, Batteries and Equipment, excluding Tubes Packed separately

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063520

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

49770

Uniform Freight Classification (UFC_CD_MODF_3040)

WAVEGUIDE-IN-BOXES-CRATES

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5985-00-296-1950 Submit RFQ
MRCDecoded RequirementClear Text Reply
ACJLBend Angle In Deg90.0 ALL BENDS E-PLANE
AAGRCross-Sectional Shape StyleINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
AHTDFlange Depth0.438 INCHES NOMINAL SECOND FLANGE
AHTDFlange Depth0.625 INCHES NOMINAL FIRST FLANGE
CSQTFlange Connecting Facility And Quantity4 THREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY
CSQTFlange Connecting Facility And Quantity4 UNTHREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY
AHTNFlange Connecting Hole Diameter0.169 INCHES NOMINAL SECOND FLANGE SINGLE CONNECTION FACILITY
AHSYFlange Inside Height0.628 INCHES NOMINAL SECOND FLANGE
AHSXFlange Inside Width1.122 INCHES NOMINAL FIRST FLANGE
AHSXFlange Inside Width1.253 INCHES NOMINAL SECOND FLANGE
AHTBFlange Inside Diameter1.625 INCHES NOMINAL ALL FLANGES
AHSYFlange Inside Height0.497 INCHES NOMINAL FIRST FLANGE
CTCJFlange StyleCHOKE TYPE FIRST FLANGE
CTCJFlange StyleCOVER TYPE SECOND FLANGE
AHTAFlange Outside Height1.875 INCHES NOMINAL FIRST FLANGE
AHTAFlange Outside Height1.875 INCHES NOMINAL SECOND FLANGE
AHSZFlange Outside Width1.875 INCHES NOMINAL FIRST FLANGE
AHSZFlange Outside Width1.875 INCHES NOMINAL SECOND FLANGE
AHSFFlange Quantity2
FLEXFlexibilityRIGID SINGLE TUBING SEGMENT
ZZZVFsc Application DataRADAR EQUIPMENT,EXCEPT AIRBORNE
MATTMaterialCOPPER ALLOY ALL TUBING SEGMENT AND FLANGE
CQJXNominal Thread Size0.164 INCHES FIRST FLANGE SINGLE CONNECTION FACILITY
STYLStyle DesignatorOFFSET BEND TYPE
AHRVTubing Wall Construction StyleSEAMLESS SINGLE TUBING SEGMENT
CTFDWaveguide Length5.317 FEET NOMINAL
CSFCWaveguide Outside Height0.625 INCHES NOMINAL
CXBBWaveguide Center To Center Distance2.750 INCHES NOMINAL
CRLBWaveguide Inside Height0.497 INCHES NOMINAL
CRFHWaveguide Inside Width1.122 INCHES NOMINAL
CQHNWaveguide Outside Width1.250 INCHES NOMINAL
SFTTSurface TreatmentCHROMATE ZINC ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
AAJFThread DirectionRIGHT-HAND FIRST FLANGE SINGLE CONNECTION FACILITY
AAJDThread Class2B FIRST FLANGE SINGLE CONNECTION FACILITY
CMLPThread Quantity Per Inch32 FIRST FLANGE SINGLE CONNECTION FACILITY
THSDThread Series DesignatorUNC FIRST FLANGE SINGLE CONNECTION FACILITY


Back to Top
Back to Top