5985-00-454-9907

WAVEGUIDE ASSEMBLY


5985-00-454-9907 (5985004549907, 004549907)
Part Number (1 listing): 10667178
Summary

FSG 59 / FSC 5985

DEMIL: D

DEMIL INT:

HMIC: P

Date Created: 2 Jun 1971

Unit Weight: 0.3 lbs

Unit Size: 3in x 2.5in x 2in

Unit Pack Cube: 0.009 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5985-00-454-9907 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
106671783 - Design Control Reference2 - Production ItemU S ARMY AVIATION AND MISSILE  18876    CAGE 18876  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5985-00-454-9907 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595985004549907A073A000305X43DPS02 Jun 1971
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5985

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Antennas, Waveguides, and Related Equipment

004549907

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5985-00-454-9907

A073A0

Federal Item Identification Guide (FIIG_4065)

00305

Item Naming Code (INC_4080)

2 Jun 1971

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5985-00-454-9907 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU011 Apr 1991
ZW011 Nov 2005
ZH011 Oct 2009
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5985-00-454-9907 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
332ATXD10667178  18876   CAGE/18876
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

TX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Columbus, Columbus, OH 43218

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5985-00-454-9907 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6BD021 Apr 1971
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

BD

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

21 Apr 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5985-00-454-9907 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
BD723Z9AHZW126880Z64300POWER-TRANS-SHAFTING-PULLEYS
Code Definitions

BD

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230

723

Water Commodity Code (WRT_CMDTY_CD_9275)


Radio Parts, Batteries and Equipment, excluding Tubes Packed separately

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

126880

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

64300

Uniform Freight Classification (UFC_CD_MODF_3040)

POWER-TRANS-SHAFTING-PULLEYS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG W - PACKAGING DATA | NSN 5985-00-454-9907 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
APAZZZ0.3 lbs3in x 2.5in x 2in0.009 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
ZZZZZZZZZZZ
Code Definitions

A

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

A

Item Type Storage Code (ITM_TYP_STOR_5156)


Heated General Purpose – Heated 40 F and above

ZZ

Method of Preservation Code (MTHD_PRSRV_CD_5160)


See J.4.1.b

Z

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Special Requirements - See specific instructions or drawings provided.

0.3 lbs

Unit Pack Weight (UP_WT_5153)

3in x 2.5in x 2in

Unit Pack Size (UP_SZ_5154)

0.009 cu ft

Unit Pack Cube (UP_CU_5155)

ZZ

Preservation Material Code (PRSRV_MAT_CD_5162)


Special requirement – See specific instructions or drawings provided

ZZ

Wrapping Material Code (WRAP_MAT_CD_5163)


Special requirements – see specific instructions or drawings provided

ZZ

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


Special requirements. See specific instructions or drawings provided.

Z

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


Special requirements-See specific instructions or drawings provided

ZZ

Unit Container Code (UNIT_CTNR_CD_5166)


Special requirement – See specific instructions or drawings provided.

ZZ

Intermediate Container Code (INTMD_CTNR_CD_5167)


Special requirement – See specific instructions or drawings provided.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5985-00-454-9907 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAGRCross-Sectional Shape StyleINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
AHTDFlange Depth0.360 INCHES MINIMUM FIRST FLANGE AND 0.390 INCHES MAXIMUM FIRST FLANGE
CSQTFlange Connecting Facility And Quantity4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES
AHSXFlange Inside Width0.620 INCHES MINIMUM FIRST FLANGE AND 0.624 INCHES MAXIMUM FIRST FLANGE
AHTBFlange Inside Diameter0.985 INCHES MINIMUM FIRST FLANGE AND 1.015 INCHES MAXIMUM FIRST FLANGE
AHSYFlange Inside Height0.309 INCHES MINIMUM FIRST FLANGE AND 0.313 INCHES MAXIMUM FIRST FLANGE
CTCJFlange StyleCHOKE TYPE FIRST FLANGE
AHTAFlange Outside Height1.297 INCHES MINIMUM FIRST FLANGE AND 1.327 INCHES MAXIMUM FIRST FLANGE
AHSZFlange Outside Width1.297 INCHES MINIMUM FIRST FLANGE AND 1.327 INCHES MAXIMUM FIRST FLANGE
AHSFFlange Quantity2
FLEXFlexibilityRIGID SINGLE TUBING SEGMENT
ZZZVFsc Application DataANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT
MATTMaterialCOPPER ALLOY ALL TUBING SEGMENT AND FLANGE
CQGMMaximum Operating Pressure30.0 POUNDS PER SQUARE INCH GAGE
CQJXNominal Thread Size0.138 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
STYLStyle DesignatorBEND TYPE
PMLCPrecious Material And LocationINTERNAL SURFACES SILVER
PRMTPrecious MaterialSILVER
CMLPThread Quantity Per Inch32 FIRST FLANGE ALL CONNECTION FACILITIES
THSDThread Series DesignatorUNC FIRST FLANGE ALL CONNECTION FACILITIES
AHRVTubing Wall Construction StyleSEAMLESS SINGLE TUBING SEGMENT
AHTWVoltage Standing Wave Ratio1.06
CSPLWaveguide Longer Offset Distance1.000 INCHES NOMINAL
CWBGWaveguide Offset Distance0.875 INCHES NOMINAL
CRLBWaveguide Inside Height0.3085 INCHES MINIMUM AND 0.3135 INCHES MAXIMUM
CRFHWaveguide Inside Width0.6195 INCHES MINIMUM AND 0.6245 INCHES MAXIMUM
CSFCWaveguide Outside Height0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM
CQHNWaveguide Outside Width0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM
SFTTSurface TreatmentENAMEL BAKED ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PRIMER ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
SFTTSurface TreatmentSILVER ALL TUBING SEGMENT AND FLANGE INSIDE SURFACES
AAJFThread DirectionRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
AAJDThread Class2B FIRST FLANGE ALL CONNECTION FACILITIES


Back to Top
Back to Top