Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
2115843REVB | 3 - Design Control Reference | 2 - Production Item | NAVAIR AND NAVSEA MANAGED | 10001 | ![]() |
1024242 | 5 - Replaced / Discontinued | 2 - Production Item | LOCKHEED MARTIN CORPORATION | 56232 | ![]() |
2115843 | 5 - Replaced / Discontinued | 2 - Production Item | NAVAIR AND NAVSEA MANAGED | 10001 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5985 | 007359323 | A073A0 | 00305 | X | K | D | P | S | 0 | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item contains silver.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZR01 | 1 Jul 1997 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 2 | 2 | HH | B | 2115843REVB | 10001 | ![]() |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
Navy ICP, Mechanicsburg, PA 17055-0788
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | BF | 0 | 17 Apr 1973 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P | 723 | Z | 9 | A | H | Z | W | 063520 | Z | 49770 | WAVEGUIDE-IN-BOXES-CRATES | 1 |
77.5
Radio Parts, Batteries and Equipment, excluding Tubes Packed separately
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
AIR FORCE ERRC ND2: AF Equipment Management System (AFEMS); NAVY: Slow Demand Velocity Items (Consumables)
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ACJL | Bend Angle In Deg | 162.49 SINGLE BEND E-PLANE |
AAGR | Cross-Sectional Shape Style | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
CSQT | Flange Connecting Facility And Quantity | 4 THREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY |
CSQT | Flange Connecting Facility And Quantity | 4 UNTHREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
AHTN | Flange Connecting Hole Diameter | 0.167 INCHES MINIMUM SECOND FLANGE SINGLE CONNECTION FACILITY AND 0.172 INCHES MAXIMUM SECOND FLANGE SINGLE CONNECTION FACILITY |
AHSY | Flange Inside Height | 0.494 INCHES MINIMUM FIRST FLANGE AND 0.500 INCHES MAXIMUM FIRST FLANGE |
AHSY | Flange Inside Height | 0.494 INCHES MINIMUM SECOND FLANGE AND 0.500 INCHES MAXIMUM SECOND FLANGE |
AHTD | Flange Depth | 0.625 INCHES NOMINAL FIRST FLANGE |
AHTD | Flange Depth | 0.625 INCHES NOMINAL SECOND FLANGE |
AHSX | Flange Inside Width | 1.119 INCHES MINIMUM FIRST FLANGE AND 1.125 INCHES MAXIMUM FIRST FLANGE |
AHSX | Flange Inside Width | 1.119 INCHES MINIMUM SECOND FLANGE AND 1.125 INCHES MAXIMUM SECOND FLANGE |
AHTA | Flange Outside Height | 1.875 INCHES NOMINAL FIRST FLANGE |
AHTA | Flange Outside Height | 1.875 INCHES NOMINAL SECOND FLANGE |
AHSZ | Flange Outside Width | 1.870 INCHES MINIMUM FIRST FLANGE AND 1.880 INCHES MAXIMUM FIRST FLANGE |
AHSZ | Flange Outside Width | 1.875 INCHES NOMINAL SECOND FLANGE |
AHSF | Flange Quantity | 2 |
CTCJ | Flange Style | CHOKE TYPE FIRST FLANGE |
CTCJ | Flange Style | CHOKE TYPE SECOND FLANGE |
FLEX | Flexibility | RIGID SINGLE TUBING SEGMENT |
MATT | Material | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
CQGM | Maximum Operating Pressure | 12.0 POUNDS PER SQUARE INCH GAGE |
CQJX | Nominal Thread Size | 0.164 INCHES FIRST FLANGE SINGLE CONNECTION FACILITY |
STYL | Style Designator | BEND TYPE |
AHRV | Tubing Wall Construction Style | SEAMLESS SINGLE TUBING SEGMENT |
CRLB | Waveguide Inside Height | 0.495 INCHES MINIMUM AND 0.499 INCHES MAXIMUM |
CRFH | Waveguide Inside Width | 1.120 INCHES MINIMUM AND 1.124 INCHES MAXIMUM |
CSPL | Waveguide Longer Offset Distance | 11.081 INCHES MINIMUM AND 11.111 INCHES MAXIMUM |
CWBG | Waveguide Offset Distance | 2.312 INCHES NOMINAL |
CSFC | Waveguide Outside Height | 0.623 INCHES MINIMUM AND 0.627 INCHES MAXIMUM |
CQHN | Waveguide Outside Width | 1.248 INCHES MINIMUM AND 1.252 INCHES MAXIMUM |
SFTT | Surface Treatment | ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
SFTT | Surface Treatment | SILVER ALL TUBING SEGMENT AND FLANGE INSIDE SURFACES |
AAJD | Thread Class | 2B FIRST FLANGE SINGLE CONNECTION FACILITY |
AAJF | Thread Direction | RIGHT-HAND FIRST FLANGE SINGLE CONNECTION FACILITY |
THSD | Thread Series Designator | UNC FIRST FLANGE SINGLE CONNECTION FACILITY |