Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
DIC-25-647-G1 | 3 - Design Control Reference | 2 - Production Item | DIAMOND ANTENNA AND MICROWAVE | 01882 | |
SM-A-720930-1 | 5 - Replaced / Discontinued | 2 - Production Item | US ARMY COMMUNICATIONS & | 80063 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5985 | 010307497 | T389-C | 00371 | N | M | 3 | B | P | A | A | 0 | 11 Nov 1976 |
The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A502 | 0 | 0 | A | E | CL | TB | 1 Apr 1991 | |||||||||||||||||||||||
NSLL | 0 | 0 | 5 | E | TB | GG | 1 Dec 1995 |
Not Established
An activitiy within the Army is providing depot maintenance support.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
Depot Reparable Component (Type II). This code identifies SICA managed depot reparable components assigned to another service which is responsible for the logistics functions of single submitter cataloger, acquisition and disposal authority, depot maintenance, and performs the wholesale stock, store, and issue functions and establishes, budgets, and funds the wholesale stock level requirement. Supply requirements will be submitted to the PICA on requisitions which are funded by a designated point within the SICA. Unserviceable SICA assets will normally be returned to the PICA for credit. The SICA will provide item/program data required by the PICA to meet the materiel support commitments. Normally, Military Interdepartmental Purchase Requests (MIPR) will not be requested by the PICA to support SICA NIMSC 5 requirements. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Tobyhanna Army Depot (TYAD), PA
Naval Inventory Control Point, Philadelphia, PA 19111û5098
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 2 | 5 | CL | A | DIC-25-647-G1 | 01882 | |||||
1 | 5 | 2 | 5 | CL | A | SM-A-720930-1 | 80063 |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 18 Nov 1976 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CL | M | 72D | Z | 9 | A | H | Z | W | 062820 | Z | 35080 | RADIO-TV-TRANSMIT-RECEIVE-SETS | 1 |
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
85
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
US Army Communications-Electronics, Command and Fort Monmout, Fort Monmouth, NJ 07703-5016
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Low Sensitivity (SRC IV) – UNCLASSIFIED AA&E. Weapon components, such as silencers, mufflers and noise suppression devices will be treated as Security Risk Category II items. The frame or receiver of an arm constitutes a weapon and such parts shall be stored according to the applicable category; e.g., the receiver of a .30 caliber machine gun shall be stored as a Category II arm. Major parts for arms (such as barrels and major subassemblies) shall be afforded at least the same protection as Security Risk Category IV Arms.
1
ARMY: Disposal is not authorized below wholesale/specialized repair activity level; MARINE CORPS: Reparable item. Repair, condemnation, and disposal not authorized below depot/specialized repair activity level; NAVY: Local stock items or items pending national stock number assignment
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
Department of the Army
Department of the Navy
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | A | 42 | 1 | 0.1 lbs | 0.1in x 0.1in x 0.1in | 0.001 cu ft | 0.1 lbs | 0.1in x 0.1in x 0.1in |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | X | ED | 00 | B | 00 | 8 | 8 | M |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
Heated General Purpose – Heated 40 F and above
Container, watervaporproof bag, sealed, container
Any suitable process that is not injurious to the item.
No requirement
No requirement
As required to protect the item or elements of the package
ASTM-D5118, Type CF, Class weather resistant, corrugated fiberboard box.
No requirement.
Unit container provides level B packing protection.
No special marking
Packing shall be accomplished in accordance with the Level A packing requirements as specified for the item.
Packing shall be accomplished in accordance with the Level A packing requirements as specified for the item.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
MATT | Material | COPPER ALLOY |
ALGC | Mounting Configuration | SIX 0.290 IN. DIA MTG HOLES SPACED 60 DEG APART ON A 3.500 IN.RADIUS |
ANKZ | Radio Frequency Rating | 7.9 GIGAHERTZ MINIMUM AND 8.4 GIGAHERTZ MAXIMUM |
ABKW | Overall Height | 4.250 INCHES NOMINAL |
ABHP | Overall Length | 9.000 INCHES NOMINAL |
ABMK | Overall Width | 8.000 INCHES NOMINAL |
APQB | Unit Type | WAVEGUIDE |
BGPS | Voltage Standing Wave Ratio At Reference Frequency | 1.2 TO 1 AT 8.1GHZ |