| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 654VE4831-1 | 3 - Design Control Reference | 2 - Production Item | LOCKHEED MARTIN CORPORATION | 81755 | |
| TT137-112 | 5 - Replaced / Discontinued | 9 - No Longer Used | GENERAL DYNAMICS SATCOM | 50478 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5985 | 011098857 | A073A0 | 00186 | X | 1 | D | P | A | 23 Mar 1981 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZF01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 3 | 2 | 1 | TX | D | 654VE4831-1 | 81755 | | ||||
| 4 | 5 | 9 | 1 | TX | B | TT137-112 | 50478 | | ||||
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 6 | TX | 0 | 28 Mar 1981 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TX | 72D | Z | 9 | A | H | Z | W | 063520 | Z | 49770 | WAVEGUIDE-IN-BOXES-CRATES |
Defense Supply Center Columbus, Columbus, OH 43218
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
| Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
|---|---|---|---|---|---|---|---|---|---|---|---|
| P | P | ZZ | XXX |
| Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
|---|---|---|---|---|---|---|---|---|---|---|---|
| X | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
See J.4.1.b
As required to protect the item or elements of the package
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| BBPN | Adapter Length | 6.500 INCHES NOMINAL |
| AAGR | Cross-Sectional Shape Style | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| AHTD | Flange Depth | 0.610 INCHES MINIMUM FIRST FLANGE AND 0.640 INCHES MAXIMUM FIRST FLANGE |
| AHTD | Flange Depth | 0.735 INCHES MINIMUM SECOND FLANGE AND 0.765 INCHES MAXIMUM SECOND FLANGE |
| CSQT | Flange Connecting Facility And Quantity | 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
| CSQT | Flange Connecting Facility And Quantity | 6 THREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
| AHSY | Flange Inside Height | 0.493 INCHES MINIMUM FIRST FLANGE AND 0.501 INCHES MAXIMUM FIRST FLANGE |
| AHSY | Flange Inside Height | 0.618 INCHES MINIMUM SECOND FLANGE AND 0.626 INCHES MAXIMUM SECOND FLANGE |
| AHSX | Flange Inside Width | 1.118 INCHES MINIMUM FIRST FLANGE AND 1.126 INCHES MAXIMUM FIRST FLANGE |
| AHSX | Flange Inside Width | 1.368 INCHES MINIMUM SECOND FLANGE AND 1.376 INCHES MAXIMUM SECOND FLANGE |
| AHTB | Flange Inside Diameter | 1.625 INCHES NOMINAL SINGLE FLANGE |
| AHSF | Flange Quantity | 2 |
| CTCJ | Flange Style | CHOKE TYPE SECOND FLANGE |
| CTCJ | Flange Style | CHOKE TYPE FIRST FLANGE |
| AHTC | Flange Outside Diameter | 3.125 INCHES NOMINAL SINGLE FLANGE |
| AHTA | Flange Outside Height | 1.875 INCHES NOMINAL SINGLE FLANGE |
| AHSZ | Flange Outside Width | 1.875 INCHES NOMINAL SINGLE FLANGE |
| MATT | Material | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
| CQJX | Nominal Thread Size | 0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES |
| CQJX | Nominal Thread Size | 0.190 INCHES SECOND FLANGE ALL CONNECTION FACILITIES |
| STYL | Style Designator | WAVEGUIDE TO WAVEGUIDE |
| AHRV | Tubing Wall Construction Style | SEAMLESS SINGLE TUBING SEGMENT |
| CRLB | Waveguide Inside Height | 0.497 INCHES NOMINAL AND 0.622 INCHES NOMINAL |
| CRFH | Waveguide Inside Width | 1.122 INCHES NOMINAL AND 1.372 INCHES NOMINAL |
| CSFC | Waveguide Outside Height | 0.625 INCHES NOMINAL AND 0.750 INCHES NOMINAL |
| CQHN | Waveguide Outside Width | 1.250 INCHES NOMINAL AND 1.500 INCHES NOMINAL |
| SFTT | Surface Treatment | CADMIUM ALL TUBING SEGMENT AND FLANGE ALL SURFACES |
| AAJD | Thread Class | 2B ALL FLANGES ALL CONNECTION FACILITIES |
| AAJF | Thread Direction | RIGHT-HAND ALL FLANGES ALL CONNECTION FACILITIES |
| THSD | Thread Series Designator | UNC FIRST FLANGE ALL CONNECTION FACILITIES |
| THSD | Thread Series Designator | UNF SECOND FLANGE ALL CONNECTION FACILITIES |
| CMLP | Thread Quantity Per Inch | 32 ALL FLANGES ALL CONNECTION FACILITIES |