| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| B4014621 | 1 - Source of Control Reference | 2 - Production Item | DEPARTMENT OF THE ARMY HQ | 56996 | |
| B4014621 | 3 - Design Control Reference | 2 - Production Item | MICROWAVE ENGINEERING CORPORATION | 06351 | |
| B4014621 | 3 - Design Control Reference | 2 - Production Item | HARRIS CORPORATION | 91417 | |
| 226211 | 3 - Design Control Reference | 2 - Production Item | MICROTECH, INC. | 54647 | |
| B4014621 | 5 - Replaced / Discontinued | 9 - No Longer Used | LITTON SYSTEMS INC | 80006 | |
| B4014621 | C - Advisory Reference | 1 - Incomplete Part Number | CONTINENTAL MICROWAVE AND TOOL CO., | 66544 | |
| B4014621 | C - Advisory Reference | 1 - Incomplete Part Number | CONTINENTAL MICROWAVE AND TOOL CO., | 66544 | |
| B4014621 | C - Advisory Reference | 1 - Incomplete Part Number | CONTINENTAL MICROWAVE AND TOOL CO., | 66544 | |
Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5985 | 011751837 | A073A0 | 00305 | X | 1 | A | P | A | 27 Mar 1984 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A918 | A196 | 3 | B | Z | CD | CL | 1 Apr 2006 | |||||||||||||||||||||||
| FXGX | 3 | B | Z | SX | 1 Apr 2006 | |||||||||||||||||||||||||
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
Acquisition of this part is restricted to source(s) specified on "Source Control", "Altered Item" or "Selected Item" drawings/documents. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | A | TX | B4014621 | 56996 | | ||||||
| 3 | 2 | 5 | TX | B4014621 | 06351 | | ||||||
| 3 | 2 | 5 | ZZ | 226211 | 54647 | | ||||||
| 3 | 2 | 5 | TX | B4014621 | 91417 | | ||||||
| 5 | 9 | 5 | TX | B | B4014621 | 80006 | | |||||
| C | 1 | 5 | ZZ | 9X | B4014621 | 66544 | | |||||
Source of Control Reference. The number assigned by a design control manufacturer of an end item of equipment, including a Government activity, to a drawing that restricts procurement (1) to the specified item(s) described on the drawing and (2) to the stated source(s) of supply designated thereon. These restrictions are imposed on the cognizant design activity to ensure procurement of the only item(s) known as a result of test or evaluation to be satisfactory for the stated critical application. Includes only those drawings which meet the definition for Source Control Drawing in MIL-STD-100. (Applicable only to type 1, 1B, 2, 4 and 4B item identifications.)
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
USA
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
GIRDER
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 6 | TX | 0 | 30 Mar 1984 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TX | 723 | Z | 9 | A | H | Z | W | 063520 | Z | 49770 | WAVEGUIDE-IN-BOXES-CRATES |
Defense Supply Center Columbus, Columbus, OH 43218
Radio Parts, Batteries and Equipment, excluding Tubes Packed separately
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Department of the Air Force
Defense Logistics Agency
| Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
|---|---|---|---|---|---|---|---|---|---|---|---|
| P | P | 41 | 1 | AAA | 1.2 lbs | 0.032 cu ft |
| Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 00 | 00 | NA | X | D3 | DO | 00 | Q | Q | U | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
No requirement
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AAGR | Cross-Sectional Shape Style | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| AHTN | Flange Connecting Hole Diameter | 0.169 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
| AHTD | Flange Depth | 0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
| AHTD | Flange Depth | 0.610 INCHES MINIMUM FIRST FLANGE AND 0.640 INCHES MAXIMUM FIRST FLANGE |
| CSQT | Flange Connecting Facility And Quantity | 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES |
| CSQT | Flange Connecting Facility And Quantity | 4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
| AHSY | Flange Inside Height | 0.493 INCHES MINIMUM FIRST FLANGE AND 0.501 INCHES MAXIMUM FIRST FLANGE |
| AHSY | Flange Inside Height | 0.628 INCHES MINIMUM SECOND FLANGE AND 0.631 INCHES MAXIMUM SECOND FLANGE |
| AHSX | Flange Inside Width | 1.218 INCHES MINIMUM FIRST FLANGE AND 1.226 INCHES MAXIMUM FIRST FLANGE |
| AHSX | Flange Inside Width | 1.253 INCHES MINIMUM SECOND FLANGE AND 1.256 INCHES MAXIMUM SECOND FLANGE |
| AHTB | Flange Inside Diameter | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
| AHSF | Flange Quantity | 2 |
| CTCJ | Flange Style | CHOKE TYPE FIRST FLANGE |
| CTCJ | Flange Style | COVER TYPE SECOND FLANGE |
| AHTA | Flange Outside Height | 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |
| AHTA | Flange Outside Height | 1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
| AHSZ | Flange Outside Width | 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |
| AHSZ | Flange Outside Width | 1.860 INCHES MINIMUM SECOND FLANGE AND 1.890 INCHES MAXIMUM SECOND FLANGE |
| FLEX | Flexibility | FLEXIBLE SECOND TUBING SEGMENT |
| FLEX | Flexibility | RIGID FIRST TUBING SEGMENT |
| ZZZV | Fsc Application Data | ANTENNAS,WAVEGUIDES AND RELATED EQUIP. |
| MATT | Material | ALUMINUM ALLOY FIRST TUBING SEGMENT |
| MATT | Material | COPPER ALLOY SECOND TUBING SEGMENT |
| MATT | Material | COPPER ALLOY ALL FLANGE |
| CQJX | Nominal Thread Size | 0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES |
| STYL | Style Designator | OFFSET BEND TYPE |
| AHRV | Tubing Wall Construction Style | CORRUGATED SECOND TUBING SEGMENT |
| AHRV | Tubing Wall Construction Style | SEAMLESS FIRST TUBING SEGMENT |
| AHTW | Voltage Standing Wave Ratio | 1.10 |
| CRLB | Waveguide Inside Height | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
| CRFH | Waveguide Inside Width | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM |
| CTFD | Waveguide Length | 4.090 INCHES NOMINAL |
| CXBB | Waveguide Center To Center Distance | 2.280 INCHES NOMINAL |
| CSFC | Waveguide Outside Height | 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
| CQHN | Waveguide Outside Width | 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |
| SFTT | Surface Treatment | PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| AAJD | Thread Class | 2B FIRST FLANGE ALL CONNECTION FACILITIES |
| AAJF | Thread Direction | RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES |
| THSD | Thread Series Designator | UNC FIRST FLANGE ALL CONNECTION FACILITIES |