| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 401NF | 3 - Design Control Reference | 2 - Production Item | WAVELINE INCORPORATED | 00443 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5985 | 012373982 | A073A0 | 00186 | X | 1 | A | P | A | 30 Jul 1986 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FXGX | FXTX | 3 | C | Z | SX | 1 Apr 2006 | ||||||||||||||||||||||||
| ZX01 | 1 Dec 2006 | |||||||||||||||||||||||||||||
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 2 | A | TX | 401NF | 00443 | | ||||||
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 30 Jul 1986 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TH | 72D | Z | 9 | A | H | Z | W | 063520 | Z | 49770 | WAVEGUIDE-IN-BOXES-CRATES |
Defense Supply Center Columbus, Columbus, OH 43215
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Defense Logistics Agency
| Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
|---|---|---|---|---|---|---|---|---|---|---|---|
| P | P | 42 | 1 | AAA | 1.1 lbs | 0.050 cu ft |
| Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 00 | 00 | NA | X | DO | 00 | Q | Q | U | M |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Container, watervaporproof bag, sealed, container
Any suitable process that is not injurious to the item.
No requirement
No requirement
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
Any suitable fiber box included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.
All packaging data is mandatory for compliance and no substitutions are permitted. Fast packs should be included in this category.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| CSRQ | Adapter Diameter | 3.110 INCHES MINIMUM AND 3.140 INCHES MAXIMUM |
| BBPN | Adapter Length | 2.094 INCHES MINIMUM AND 2.156 INCHES MAXIMUM |
| CWBQ | Adapter Overall Height | 3.110 INCHES MINIMUM AND 3.140 INCHES MAXIMUM |
| AHUC | Coaxial Connector Series Designation | N |
| AHUD | Connector End Design | FEMALE |
| AAGR | Cross-Sectional Shape Style | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| AGAV | End Item Identification | TRAINING SET,TACTICAL ELECTRONIC WARFARE AN/MSQ-T13 |
| AHTN | Flange Connecting Hole Diameter | 0.199 INCHES MINIMUM SINGLE FLANGE ALL CONNECTION FACILITIES AND 0.203 INCHES MAXIMUM SINGLE FLANGE ALL CONNECTION FACILITIES |
| AHTD | Flange Depth | 0.360 INCHES MINIMUM SINGLE FLANGE AND 0.390 INCHES MAXIMUM SINGLE FLANGE |
| CSQT | Flange Connecting Facility And Quantity | 6 UNTHREADED HOLE SINGLE FLANGE ALL CONNECTION FACILITIES |
| AHSY | Flange Inside Height | 0.753 INCHES MINIMUM SINGLE FLANGE AND 0.756 INCHES MAXIMUM SINGLE FLANGE |
| AHSX | Flange Inside Width | 1.503 INCHES MINIMUM SINGLE FLANGE AND 1.506 INCHES MAXIMUM SINGLE FLANGE |
| AHSF | Flange Quantity | 1 |
| CTCJ | Flange Style | COVER TYPE SINGLE FLANGE |
| AHTC | Flange Outside Diameter | 3.110 INCHES MINIMUM SINGLE FLANGE AND 3.140 INCHES MAXIMUM SINGLE FLANGE |
| ZZZV | Fsc Application Data | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
| MATT | Material | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
| AHTZ | Output Impedance Rating In Ohms | 50.0 |
| STYL | Style Designator | WAVEGUIDE TO COAXIAL |
| AHTY | Input Impedance Rating In Ohms | 50.0 |
| FEAT | Special Features | FREQUENCY RANGE 5.85 TO 8.20 GHZ |
| AHRV | Tubing Wall Construction Style | SEAMLESS SINGLE TUBING SEGMENT |
| AHTW | Voltage Standing Wave Ratio | 1.25 |
| CSFC | Waveguide Outside Height | 0.746 INCHES MINIMUM AND 0.754 INCHES MAXIMUM |
| CRLB | Waveguide Inside Height | 0.618 INCHES MINIMUM AND 0.626 INCHES MAXIMUM |
| CRFH | Waveguide Inside Width | 1.368 INCHES MINIMUM AND 1.376 INCHES MAXIMUM |
| CQHN | Waveguide Outside Width | 1.496 INCHES MINIMUM AND 1.504 INCHES MAXIMUM |
| SFTT | Surface Treatment | CHROMATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND ENAMEL BAKED ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |