Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
XLXT91 | 3 - Design Control Reference | 9 - No Longer Used | 3DBM CO INC | 31791 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5985 | 012931091 | A073A0 | 00186 | X | 4 | 3 | B | P | A | 26 Jan 1989 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZC01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 9 | E | TX | XLXT91 | 31791 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Columbus, Columbus, OH 43218
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 26 Jan 1989 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TH | 723 | Z | 9 | A | H | Z | J | 013120 | F | 05380 | ALUMINUM-ARTICLE-NOI-SUB-6 |
Defense Supply Center Columbus, Columbus, OH 43215
Radio Parts, Batteries and Equipment, excluding Tubes Packed separately
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
100.2
No Variation. NMFC and UFCC Match.
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | 41 | 1 | AAA | 0.4 lbs | 0.067 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | DO | 00 | E | Q | U | O |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
No requirement
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
Any suitable fiber box included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
BBPN | Adapter Length | 3.000 INCHES NOMINAL |
AAGR | Cross-Sectional Shape Style | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
AHTD | Flange Depth | 0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
AHTD | Flange Depth | 0.610 INCHES MINIMUM FIRST FLANGE AND 0.640 INCHES MAXIMUM FIRST FLANGE |
CSQT | Flange Connecting Facility And Quantity | 4 THREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY |
AHTB | Flange Inside Diameter | 1.406 INCHES MINIMUM SECOND FLANGE AND 1.437 INCHES MAXIMUM SECOND FLANGE |
AHTB | Flange Inside Diameter | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
AHSY | Flange Inside Height | 0.396 INCHES MINIMUM SECOND FLANGE AND 0.404 INCHES MAXIMUM SECOND FLANGE |
AHSY | Flange Inside Height | 0.493 INCHES MINIMUM FIRST FLANGE AND 0.501 INCHES MAXIMUM FIRST FLANGE |
AHSX | Flange Inside Width | 0.896 INCHES MINIMUM SECOND FLANGE AND 0.904 INCHES MAXIMUM SECOND FLANGE |
AHSX | Flange Inside Width | 1.118 INCHES MINIMUM FIRST FLANGE AND 1.126 INCHES MAXIMUM FIRST FLANGE |
AHSZ | Flange Outside Width | 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |
AHSF | Flange Quantity | 2 |
CTCJ | Flange Style | CHOKE TYPE FIRST FLANGE |
CTCJ | Flange Style | CHOKE TYPE SECOND FLANGE |
AHTA | Flange Outside Height | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTA | Flange Outside Height | 1.860 INCHES MINIMUM FIRST FLANGE AND 1.890 INCHES MAXIMUM FIRST FLANGE |
AHSZ | Flange Outside Width | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
ZZZV | Fsc Application Data | RADAR EQUIPMENT |
MATT | Material | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
CQJX | Nominal Thread Size | 0.164 INCHES ALL FLANGES SINGLE CONNECTION FACILITY |
STYL | Style Designator | WAVEGUIDE TO WAVEGUIDE |
AHTX | Insertion Loss In Decibels | 0.10 |
THSD | Thread Series Designator | UNC ALL FLANGES SINGLE CONNECTION FACILITY |
AHRV | Tubing Wall Construction Style | SEAMLESS SINGLE TUBING SEGMENT |
AHTW | Voltage Standing Wave Ratio | 1.10 |
SFTT | Surface Treatment | CHROMATE ALL TUBING SEGMENT AND FLANGE ALL SURFACES |
AAJF | Thread Direction | RIGHT-HAND ALL FLANGES SINGLE CONNECTION FACILITY |
AAJD | Thread Class | 2B ALL FLANGES SINGLE CONNECTION FACILITY |