5985-01-396-2978

WAVEGUIDE ASSEMBLY


5985-01-396-2978 (5985013962978, 013962978)
Part Number (1 listing): 3003855-101
Summary

FSG 59 / FSC 5985

DEMIL: A

DEMIL INT:

HMIC: P

Date Created: 16 Sep 1994

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5985-01-396-2978 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
3003855-1013 - Design Control Reference2 - Production ItemHARRIS CORPORATION  66948    CAGE 66948  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5985-01-396-2978 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595985013962978A073A000305X1APAA016 Sep 1994
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5985

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Antennas, Waveguides, and Related Equipment

013962978

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5985-01-396-2978

A073A0

Federal Item Identification Guide (FIIG_4065)

00305

Item Naming Code (INC_4080)

16 Sep 1994

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5985-01-396-2978 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FXGXFXTX3CZSX1 Apr 2006
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

C

Acquisition Method Suffix Code (AMSC_2876)


This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043


FLIS - SEG C - REFERENCE NUMBER | NSN 5985-01-396-2978 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
32AZZ3003855-101  66948   CAGE/66948
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

A

Document Availability Code (DAC_2640)


The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5985-01-396-2978 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TX024 Sep 1994
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Columbus, Columbus, OH 43218

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

24 Sep 1994

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5985-01-396-2978 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TH723Z9AHZW063520Z49770WAVEGUIDE-IN-BOXES-CRATES
Code Definitions

TH

Originating Activity Code (ORIG_ACTY_CD_4210)


Defense Supply Center Columbus, Columbus, OH 43215

723

Water Commodity Code (WRT_CMDTY_CD_9275)


Radio Parts, Batteries and Equipment, excluding Tubes Packed separately

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

063520

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

49770

Uniform Freight Classification (UFC_CD_MODF_3040)

WAVEGUIDE-IN-BOXES-CRATES

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5985-01-396-2978 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFSMSZU0NEA0
DSSMSZU0NEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

0

Quantity Unit Pack (QUP_6106)


No QUP

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5985-01-396-2978 Submit RFQ
MRCDecoded RequirementClear Text Reply
AAGRCross-Sectional Shape StyleINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
AHTNFlange Connecting Hole Diameter0.245 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.255 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES
AHTDFlange Depth0.360 INCHES MINIMUM FIRST FLANGE AND 0.390 INCHES MAXIMUM FIRST FLANGE
AHTDFlange Depth0.360 INCHES MINIMUM SECOND FLANGE AND 0.390 INCHES MAXIMUM SECOND FLANGE
CSQTFlange Connecting Facility And Quantity4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES
CSQTFlange Connecting Facility And Quantity4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES
AHSYFlange Inside Height0.309 INCHES MINIMUM FIRST FLANGE AND 0.313 INCHES MAXIMUM FIRST FLANGE
AHSYFlange Inside Height0.309 INCHES MINIMUM SECOND FLANGE AND 0.313 INCHES MAXIMUM SECOND FLANGE
AHSXFlange Inside Width0.620 INCHES MINIMUM FIRST FLANGE AND 0.624 INCHES MAXIMUM FIRST FLANGE
AHSXFlange Inside Width0.620 INCHES MINIMUM SECOND FLANGE AND 0.624 INCHES MAXIMUM SECOND FLANGE
AHSFFlange Quantity2
CTCJFlange StyleCHOKE TYPE FIRST FLANGE
CTCJFlange StyleCOVER TYPE SECOND FLANGE
AHTAFlange Outside Height1.297 INCHES MINIMUM FIRST FLANGE AND 1.327 INCHES MAXIMUM FIRST FLANGE
AHSZFlange Outside Width1.297 INCHES MINIMUM FIRST FLANGE AND 1.327 INCHES MAXIMUM FIRST FLANGE
AHSZFlange Outside Width1.297 INCHES MINIMUM SECOND FLANGE AND 1.327 INCHES MAXIMUM SECOND FLANGE
FLEXFlexibilityFLEXIBLE SINGLE TUBING SEGMENT
MATTMaterialCOPPER ALLOY SINGLE TUBING SEGMENT
MATTMaterialCOPPER ALLOY ALL FLANGE
CQGMMaximum Operating Pressure18.0 POUNDS PER SQUARE INCH GAGE
CQJXNominal Thread Size0.138 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
STYLStyle DesignatorBEND TYPE
AHTXInsertion Loss In Decibels0.15
FEATSpecial Features16.0-17.0 GHZ OPERATING FREQUENCY
THSDThread Series DesignatorUNC FIRST FLANGE ALL CONNECTION FACILITIES
AHRVTubing Wall Construction StyleCORRUGATED SINGLE TUBING SEGMENT
AHTWVoltage Standing Wave Ratio1.05
CSPLWaveguide Longer Offset Distance20.610 INCHES NOMINAL
CWBGWaveguide Offset Distance4.500 INCHES NOMINAL
CSFCWaveguide Outside Height0.388 INCHES MINIMUM AND 0.394 INCHES MAXIMUM
CQHNWaveguide Outside Width0.699 INCHES MINIMUM AND 0.705 INCHES MAXIMUM
CRLBWaveguide Inside Height0.308 INCHES MINIMUM AND 0.314 INCHES MAXIMUM
CRFHWaveguide Inside Width0.619 INCHES MINIMUM AND 0.625 INCHES MAXIMUM
SFTTSurface TreatmentENAMEL SINGLE TUBING SEGMENT OUTSIDE SURFACES
SFTTSurface TreatmentPRIMER SINGLE TUBING SEGMENT INSIDE SURFACES
AAJFThread DirectionRIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
AAJDThread Class2B FIRST FLANGE ALL CONNECTION FACILITIES


Back to Top
Back to Top