5985-01-626-2590

SWITCH,RADIO FREQUENCY TRANSMISSION LINE


5985-01-626-2590 (5985016262590, 016262590)
Part Number (1 listing): 50SA-261
Summary

FSG 59 / FSC 5985

DEMIL: A

DEMIL INT: 1

HMIC: P

Date Created: 4 Mar 2014

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5985-01-626-2590 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
50SA-2613 - Design Control Reference2 - Production ItemJFW INDUSTRIES INCORPORATED  61162      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5985-01-626-2590 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595985016262590A158A005298X43APAA04 Mar 2014
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5985

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Antennas, Waveguides, and Related Equipment

016262590

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5985-01-626-2590

A158A0

Federal Item Identification Guide (FIIG_4065)

05298

Item Naming Code (INC_4080)

4 Mar 2014

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

P

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5985-01-626-2590 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZW011 Mar 2014
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5985-01-626-2590 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43259ZD50SA-261  61162  
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5985-01-626-2590 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59704 Mar 2014
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

4 Mar 2014

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5985-01-626-2590 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZW
Code Definitions

ZW

Originating Activity Code (ORIG_ACTY_CD_4210)


Turkey

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5985-01-626-2590 Submit RFQ
MRCDecoded RequirementClear Text Reply
AKPCActuator Operating MethodMANUAL
AHUCCoaxial Connector Series DesignationSMA
ACZBFrequency Rating18.0 GIGAHERTZ NOMINAL SINGLE FREQUENCY OPERATING
AHTXInsertion Loss In Decibels0.10 1ST
AHTXInsertion Loss In Decibels0.15 2ND
AHTXInsertion Loss In Decibels0.30 4TH
AHTXInsertion Loss In Decibels0.20 3RD
AHTXInsertion Loss In Decibels0.35 5TH
CXCYPart Name Assigned By Controlling AgencyRF SWITCH ASSY
FEATSpecial FeaturesCONFIGURATION: TWO 1P2T FAILSAFE ELECTROMECHANICAL RF SWITCHES, IMPEDANCE: 50 OHMS NOM., MANUAL CONTROL: KEYPAD AND LCD DISPLAY, REMOTE CONTROL: ETHERNET (10/100) AND RS-232, AC SUPPLY: 100-240 VAC AND 47-63 HZ 0.30 AMPS TYPICAL AT 120 VAC, OPER TEMP RANGE: 0 TO 50 DEG. C
TTQYTerminal Type And Quantity2 RECEPTACLE, COAXIAL


Back to Top
Back to Top