5990-00-518-7525

SYNCHRO,RECEIVER


5990-00-518-7525 (5990005187525, 005187525)
Part Number (1 listing): TRH11E4
Summary

FSG 59 / FSC 5990

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 13 Aug 1974

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5990-00-518-7525 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
TRH11E43 - Design Control Reference2 - Production ItemMOOG INC.  99932    CAGE 99932  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5990-00-518-7525 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595990005187525A0780002072X46ANU13 Aug 1974
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5990

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Synchros and Resolvers

005187525

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5990-00-518-7525

A07800

Federal Item Identification Guide (FIIG_4065)

02072

Item Naming Code (INC_4080)

13 Aug 1974

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5990-00-518-7525 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZC011 Apr 1991
ZF011 Apr 1991
ZG011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5990-00-518-7525 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3249ZTRH11E4  99932   CAGE/99932
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5990-00-518-7525 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59801 Feb 1975
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

98

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

1 Feb 1975

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5990-00-518-7525 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
ZFQ590Z9AHZW062120Z34760GENERATORS-MOTORS-PARTS-NOI1
Code Definitions

ZF

Originating Activity Code (ORIG_ACTY_CD_4210)


France

Q

Less Than Carload (LCL_CD_2760)


70

590

Water Commodity Code (WRT_CMDTY_CD_9275)


Generators and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062120

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34760

Uniform Freight Classification (UFC_CD_MODF_3040)

GENERATORS-MOTORS-PARTS-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5990-00-518-7525 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABPMBody Diameter1.0620 INCHES NOMINAL
AJSLBody Size11
AAQLBody StyleSTANDARD ROUND, ROTATABLE HOUSING
ABKKFlange Diameter1.0620 INCHES NOMINAL
ABKUFlange Thickness0.0620 INCHES NOMINAL
AJSSFrequency In Hertz400.0 NOMINAL
CRYYMounting Facility Nominal Screw Thread Diameter0.1120 INCHES
AKEJMounting Facility Screw Thread Series DesignatorUNC
AJWXMounting Surface To Terminal End Distance0.8860 INCHES NOMINAL
CQXQPlus J Zro Reactance In Ohms107.00 NOMINAL
CRKLPlus J Zrs Reactance In Ohms8.90 NOMINAL
CRGZPlus J Zso Reactance In Ohms18.10 NOMINAL
AJVNReceiver Error Angular Range In Minutes-15.0/+15.0
AJTSRotor Dc Resistance In Ohms8.50 NOMINAL
AJSTRotor Input Current Rating240.0 MILLIAMPERES NOMINAL
AJSVRotor Input Electrical Power Rating920.0 MILLIWATTS NOMINAL
AJSRRotor Input Voltage Rating In Volts26.0 NOMINAL
AHYFSecuring Hole Quantity4
AJWHShaft End Play0.8660 INCHES NOMINAL
ABWVShaft Diameter0.1200 INCHES NOMINAL SINGLE SHAFT
ABXFShaft Length0.3100 INCHES MINIMUM SINGLE SHAFT AND 0.3160 INCHES MAXIMUM SINGLE SHAFT
CRSJShaft TypeROUND SINGLE SHAFT
AAVHShoulder Diameter1.0620 INCHES NOMINAL
AJWRShoulder Length0.1800 INCHES MINIMUM AND 0.1920 INCHES MAXIMUM
ABHPOverall Length2.0340 INCHES MINIMUM AND 2.0400 INCHES MAXIMUM
AJVFPhase Shift Angle In Deg5.000 INPUT TO OUTPUT NOMINAL
AJVVTorque Gradient Per Angular Deg5700.000 MILLIMETER-MILLIGRAMS NOMINAL
AJSWZro Resistance In Ohms16.00 NOMINAL
AJTAZrs Resistance In Ohms22.00 NOMINAL
AJSYZso Resistance In Ohms3.70 NOMINAL
AJTTStator Dc Resistance In Ohms3.00 NOMINAL
CQTMTerminal LocationREAR
TTQYTerminal Type And Quantity2 WIRE LEAD


Back to Top
Back to Top