Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
140191 | 3 - Design Control Reference | 9 - No Longer Used | SOLARTRON ELECTRONICS INC | 65092 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5990 | 006076210 | A07800 | 22966 | X | 1 | A | N | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FXGX | FXTX | 3 | L | Z | SX | 1 Apr 2006 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The annual buy value of this part falls below the screening threshold of $10,000 but it has been screened for known source(s). (NOTE: This code shall not be used when screening parts entering the inventory. It shall not be assigned in preference to or supersede any other AMSC.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 9 | 1 | TX | D | 140191 | 65092 |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
C | KA | 0 | 6 Sep 1971 |
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
Naval Air Systems Command, Washington, DC 20360
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
72D | Z | 9 | A | H | Z | W | 061700 | Z | 34580 | ELEC-APPLIANCES-INSTRUMENTS-NOI |
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Department of the Air Force
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 41 | 1 | AAA |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | D3 | DO | 00 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
No requirement
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AJVL | Electrical Error Angular Range In Minutes | -7.0/+7.0 |
AJVS | Actuator Friction Torque At Minus 55 Deg Celsius | 16.0 CENTIMETER-GRAMS NOMINAL |
AJVT | Actuator Friction Torque At Plus 25 Deg Celsius | 6.0 CENTIMETER-GRAMS NOMINAL |
AAFZ | Body Material | STEEL, CORROSION RESISTING |
AJSL | Body Size | 15 |
AAQL | Body Style | STANDARD ROUND C |
ABKK | Flange Diameter | 1.4370 INCHES NOMINAL |
ABKU | Flange Thickness | 0.0930 INCHES NOMINAL |
AJSS | Frequency In Hertz | 400.0 NOMINAL |
AJVG | Maximum Fundamental Null Voltage In Millivolts Per Volt | 30.00 INPUT |
AJVH | Maximum Total Null Voltage Output In Millivolts Per Volt | 70.00 |
AJWX | Mounting Surface To Terminal End Distance | 1.8000 INCHES MAXIMUM |
CRKL | Plus J Zrs Reactance In Ohms | 219.00 NOMINAL |
CRGZ | Plus J Zso Reactance In Ohms | 2600.00 NOMINAL |
CQXQ | Plus J Zro Reactance In Ohms | 2740.00 NOMINAL |
AJTS | Rotor Dc Resistance In Ohms | 245.00 NOMINAL |
AJST | Rotor Input Current Rating | 12.0 MILLIAMPERES NOMINAL |
AJSV | Rotor Input Electrical Power Rating | 56.0 MILLIWATTS NOMINAL |
AJSR | Rotor Input Voltage Rating In Volts | 30.0 NOMINAL |
ABWV | Shaft Diameter | 0.1200 INCHES NOMINAL SINGLE SHAFT |
ABXF | Shaft Length | 0.5000 INCHES NOMINAL SINGLE SHAFT |
CQZS | Shaft Slot Depth | 0.0350 INCHES NOMINAL SINGLE SHAFT |
CRHN | Shaft Slot Width | 0.0250 INCHES NOMINAL SINGLE SHAFT |
CRSJ | Shaft Type | ROUND, SLOTTED SINGLE SHAFT |
AAVH | Shoulder Diameter | 1.3120 INCHES NOMINAL |
AJWR | Shoulder Length | 0.1320 INCHES NOMINAL |
ABHP | Overall Length | 2.3100 INCHES MAXIMUM |
AAVL | Pilot Diameter | 0.5000 INCHES NOMINAL |
AJVF | Phase Shift Angle In Deg | 5.000 INPUT TO OUTPUT NOMINAL |
AJWQ | Pilot Length | 0.0400 INCHES NOMINAL |
CSJY | Transformation Ratio | 0.485 ROTOR TO STATOR NOMINAL |
ABPA | Undercut Diameter | 1.3870 INCHES NOMINAL |
ABPC | Undercut Width | 0.0780 INCHES NOMINAL |
AJSW | Zro Resistance In Ohms | 582.00 NOMINAL |
AJTA | Zrs Resistance In Ohms | 376.00 NOMINAL |
AJSY | Zso Resistance In Ohms | 470.00 NOMINAL |
AJTT | Stator Dc Resistance In Ohms | 130.00 NOMINAL |
AJSP | Stator Input Current Rating | 10.7 MILLIAMPERES NOMINAL |
AJSQ | Stator Input Electrical Power Rating | 65.0 MILLIWATTS NOMINAL |
AJSN | Stator Input Voltage Rating In Volts | 30.0 NOMINAL |
CQTM | Terminal Location | REAR |
TTQY | Terminal Type And Quantity | 5 WIRE LEAD |