5990-00-644-0107

SYNCHRO,DIFFERENTIAL TRANSMITTER


5990-00-644-0107 (5990006440107, 006440107)
Part Number (1 listing): 0S3883
Summary

FSG 59 / FSC 5990

DEMIL: D

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1963

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5990-00-644-0107 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
0S38833 - Design Control Reference9 - No Longer UsedNAVAIR AND NAVSEA MANAGED  10001      
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5990-00-644-0107 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595990006440107A0780002071X1DNA01 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5990

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Synchros and Resolvers

006440107

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5990-00-644-0107

A07800

Federal Item Identification Guide (FIIG_4065)

02071

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5990-00-644-0107 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
N2H43HVEHDGG1 Apr 1991
YB011 Apr 1991
ZR011 Jul 1997
ZW011 Nov 1998
YA011 Jan 2002
Code Definitions

3

Acquisition Method Code (AMC_2871)


Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

V

Nonconsumable Item Material Support Code (NIMSC_0076)


An activity within the Navy is providing depot maintenance support.

E

Item Management Code (IMC_2744)


Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.

HD

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

GG

Supplementary Receivers (SUPPLM_RCVR_2534)


Naval Inventory Control Point, Philadelphia, PA 19111û5098


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5990-00-644-0107 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
CKA06 Sep 1971
Code Definitions

C

Item Standardization Code (ISC_2650)


An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.

KA

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Naval Air Systems Command, Washington, DC 20360

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

6 Sep 1971

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5990-00-644-0107 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Q590Z9AHZW062120Z34760GENERATORS-MOTORS-PARTS-NOI1
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Q

Less Than Carload (LCL_CD_2760)


70

590

Water Commodity Code (WRT_CMDTY_CD_9275)


Generators and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062120

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34760

Uniform Freight Classification (UFC_CD_MODF_3040)

GENERATORS-MOTORS-PARTS-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG H - MANAGEMENT DATA | NSN 5990-00-644-0107 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNNRPVU1HEA0
Code Definitions

NRP

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

H

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5990-00-644-0107 Submit RFQ
MRCDecoded RequirementClear Text Reply
ABPMBody Diameter2.7000 INCHES NOMINAL
AAFZBody MaterialALUMINUM
AJSLBody Size31
AAQLBody StyleSTANDARD ROUND, ROTATABLE HOUSING
ABKKFlange Diameter3.0980 INCHES MINIMUM AND 3.1000 INCHES MAXIMUM
ABKUFlange Thickness0.2470 INCHES MINIMUM AND 0.2530 INCHES MAXIMUM
AJSSFrequency In Hertz60.0 NOMINAL
AJWXMounting Surface To Terminal End Distance3.3800 INCHES NOMINAL
AEBZSchematic Diagram Designator1 Y-ROTOR, 1 Y-STATOR
ABWVShaft Diameter0.2405 INCHES NOMINAL SINGLE SHAFT
AJWHShaft End Play0.0040 INCHES NOMINAL
AJXBShaft Maximum Runout0.0005 INCHES
CWBHShaft Nominal Thread Size0.250 INCHES SINGLE SHAFT
AKANShaft Thread Class3A
AKAFShaft Thread DirectionRIGHT-HAND SINGLE SHAFT
CQWQShaft Thread Length0.2670 INCHES NOMINAL SINGLE SHAFT
AJYYShaft Thread Series DesignatorUNF SINGLE SHAFT
CRSJShaft TypeSPLINE W/THREADS SINGLE SHAFT
ABXFShaft Length0.6810 INCHES MINIMUM SINGLE SHAFT AND 0.7060 INCHES MAXIMUM SINGLE SHAFT
AAVHShoulder Diameter2.7000 INCHES NOMINAL
AJWRShoulder Length1.0000 INCHES NOMINAL
ABHPOverall Length4.3700 INCHES NOMINAL
AJVMSpline Tooth Quantity22 SINGLE SHAFT
AJXASpline Tooth Diametral Pitch96 SINGLE SHAFT
AJSPStator Input Current Rating605.0 MILLIAMPERES NOMINAL
AJSQStator Input Electrical Power Rating13.2 WATTS NOMINAL
AJSNStator Input Voltage Rating In Volts91.8 MAXIMUM
CQTMTerminal LocationREAR
TTQYTerminal Type And Quantity5 SCREW


Back to Top
Back to Top