5990-00-675-4567

SYNCHRO,TRANSMITTER


5990-00-675-4567 (5990006754567, 006754567)
Part Numbers (3 listings): 900133-0005 | SGC29C4A223 | 900133-5 |
Summary

FSG 59 / FSC 5990

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5990-00-675-4567 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
900133-00053 - Design Control Reference2 - Production ItemNORTHROP GRUMMAN GUIDANCE AND  06481    CAGE 06481  
SGC29C4A2233 - Design Control Reference2 - Production ItemMOOG INC.  99932    CAGE 99932  
900133-55 - Replaced / Discontinued9 - No Longer UsedNORTHROP GRUMMAN GUIDANCE AND  06481    CAGE 06481  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5990-00-675-4567 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595990006754567A0780002073X1ANU1 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5990

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Synchros and Resolvers

006754567

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5990-00-675-4567

A07800

Federal Item Identification Guide (FIIG_4065)

02073

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5990-00-675-4567 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZE
ZR
ZW
ZZ
ZR011 Apr 1991
ZE011 Apr 1991
ZW011 Nov 2005
N9BN1GZGHKE1 Apr 2006
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

G

Acquisition Method Suffix Code (AMSC_2876)


The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

GH

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

KECollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval ICP, Philadelphia, PA 19111


FLIS - SEG C - REFERENCE NUMBER | NSN 5990-00-675-4567 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
325ZZ900133-0005  06481   CAGE/06481
322ZZSGC29C4A223  99932   CAGE/99932
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.


FLIS - SEG G - FREIGHT DATA | NSN 5990-00-675-4567 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
593Z9AKZW062820Z35080RADIO-TV-TRANSMIT-RECEIVE-SETS
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


593

Water Commodity Code (WRT_CMDTY_CD_9275)


Motors and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

K

Air Commodity Code (AIR_CMTY_HDLG_9215)


Clothing, including clothing equipment (other than arms and chemical supplies) cordage, fabrics and leather, parachutes, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062820

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35080

Uniform Freight Classification (UFC_CD_MODF_3040)

RADIO-TV-TRANSMIT-RECEIVE-SETS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5990-00-675-4567 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSXU1EA0
DSSMSXU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

X

Acquisition Advice Code (AAC_2507)


SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5990-00-675-4567 Submit RFQ
MRCDecoded RequirementClear Text Reply
AJVLElectrical Error Angular Range In Minutes-30.0/+30.0
ABPMBody Diameter2.0000 NOMINAL INCHES
AAFZBody MaterialSTEEL, CORROSION RESISTING
CRMRBody Thru-Hole Diameter0.5450 INCHES NOMINAL
AJSLBody Size20
AAQLBody StylePICK-OFF A
AFJNFragility FactorMODERATELY RUGGED
AJSSFrequency In Hertz5000.0 NOMINAL
AJVGMaximum Fundamental Null Voltage In Millivolts Per Volt9.00 INPUT
AJVHMaximum Total Null Voltage Output In Millivolts Per Volt18.00
AEBZSchematic Diagram Designator1 Y-ROTOR, 1 STATOR
AJSTRotor Input Current Rating28.0 MILLIAMPERES NOMINAL
AJSVRotor Input Electrical Power Rating200.0 ALLQJAA3.500 FINISHED-CHAMFERED
AJSRRotor Input Voltage Rating In Volts15.0 NOMINAL
AJTSRotor Dc Resistance In Ohms20.00 NOMINAL
ABHPOverall Length0.8500 INCHES NOMINAL
AJVFPhase Shift Angle In Deg5.000 INPUT TO OUTPUT MAXIMUM
FEATSpecial FeaturesLEADS 15 IN. MIN LG
AJTHZro Impedance Angle In Deg68.00 NOMINAL
AJTGZro Impedance Magnitude In Ohms536.00 NOMINAL
AJTKZso Impedance Angle In Deg66.00 NOMINAL
AJTJZso Impedance Magnitude In Ohms270.00 NOMINAL
AJTTStator Dc Resistance In Ohms32.00 NOMINAL
CQTMTerminal LocationSIDE
TTQYTerminal Type And Quantity5 WIRE LEAD


Back to Top
Back to Top