Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
8803903 | 3 - Design Control Reference | 2 - Production Item | PICATINNY ARSENAL | 19203 | |
AY503-8A1 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTL INC | 55972 | |
AY503-8A1 | C - Advisory Reference | 1 - Incomplete Part Number | HONEYWELL INTERNATIONAL INC. | 96774 | |
AY503-8A1 | C - Advisory Reference | 1 - Incomplete Part Number | HONEYWELL INTERNATIONAL INC. | 96774 | |
AY503-8A1 | C - Advisory Reference | 1 - Incomplete Part Number | HONEYWELL INTERNATIONAL INC. | 96774 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5990 | 006831090 | A07800 | 02073 | X | K | A | N | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZE01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
FXGX | FXTX | 3 | C | Z | SX | 1 Jul 2005 | ||||||||||||||||||||||||
N9BN | N9ND | 3 | C | Z | GH | GT | KE | 1 Jul 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval ICP, Philadelphia, PA 19111
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 5 | 9 | 5 | TX | B | AY503-8A1 | 55972 | |||||
C | 1 | 5 | ZZ | 9X | AY503-8A1 | 96774 |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Columbus, Columbus, OH 43218
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
USA
GIRDER
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | KA | 0 | 15 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Naval Air Systems Command, Washington, DC 20360
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
593 | Z | 9 | A | K | Z | W | 062820 | Z | 35080 | RADIO-TV-TRANSMIT-RECEIVE-SETS |
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Clothing, including clothing equipment (other than arms and chemical supplies) cordage, fabrics and leather, parachutes, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Unit Price | MOE | SOS | AAC | CIIC | QUP | Reparability | UI | SLC |
---|---|---|---|---|---|---|---|---|
DF | SMS | Z | U | 1 | N | EA | 0 | |
DN | SMS | Z | U | 1 | EA | 0 | ||
DS | SMS | Z | U | 1 | N | EA | 0 | |
DF | SMS | Z | U | 1 | N | EA | 0 | |
DN | SMS | Z | U | 1 | EA | 0 | ||
DS | SMS | Z | U | 1 | N | EA | 0 |
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 51 | 1 | AAA | 0.2 lbs | 0.016 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | D3 | D3 | 00 | Q | Q | U | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
No requirement
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
No special marking
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AJVL | Electrical Error Angular Range In Minutes | -15.0/+15.0 |
AJVS | Actuator Friction Torque At Minus 55 Deg Celsius | 15.0 CENTIMETER-GRAMS NOMINAL |
AJVT | Actuator Friction Torque At Plus 25 Deg Celsius | 4.0 CENTIMETER-GRAMS NOMINAL |
CTCW | Alignment Hole Bolt Circle Diameter | 0.6780 INCHES NOMINAL |
CRSY | Alignment Hole Depth | 0.0780 INCHES MAXIMUM |
AJVW | Alignment Hole Quantity | 3 |
AAFZ | Body Material | ALUMINUM |
AJSL | Body Size | 10 |
AAQL | Body Style | STANDARD ROUND C |
ABKK | Flange Diameter | 0.9360 INCHES MINIMUM AND 0.9370 INCHES MAXIMUM |
ABKU | Flange Thickness | 0.0620 INCHES NOMINAL |
AJSS | Frequency In Hertz | 400.0 NOMINAL |
AJWX | Mounting Surface To Terminal End Distance | 1.2410 INCHES NOMINAL |
CQXQ | Plus J Zro Reactance In Ohms | 145.00 NOMINAL |
CRKL | Plus J Zrs Reactance In Ohms | 26.00 NOMINAL |
CRGZ | Plus J Zso Reactance In Ohms | 33.00 NOMINAL |
CTDW | Plus J Zso-90 Reactance In Ohms | 10.70 NOMINAL |
AJST | Rotor Input Current Rating | 180.0 MILLIAMPERES NOMINAL |
AJSV | Rotor Input Electrical Power Rating | 1.7 WATTS NOMINAL |
AJSR | Rotor Input Voltage Rating In Volts | 26.0 NOMINAL |
AJTS | Rotor Dc Resistance In Ohms | 26.00 NOMINAL |
ABWV | Shaft Diameter | 0.0880 INCHES MINIMUM SINGLE SHAFT AND 0.0900 INCHES MAXIMUM SINGLE SHAFT |
CQZS | Shaft Slot Depth | 0.0300 INCHES NOMINAL SINGLE SHAFT |
CRHN | Shaft Slot Width | 0.0200 INCHES NOMINAL SINGLE SHAFT |
CRSJ | Shaft Type | ROUND, SLOTTED SINGLE SHAFT |
ABXF | Shaft Length | 0.4130 INCHES NOMINAL SINGLE SHAFT |
AAVH | Shoulder Diameter | 0.8118 INCHES MINIMUM AND 0.8123 INCHES MAXIMUM |
AJWR | Shoulder Length | 0.0630 INCHES NOMINAL |
ABHP | Overall Length | 1.6540 INCHES NOMINAL |
AJVF | Phase Shift Angle In Deg | 10.500 INPUT TO OUTPUT NOMINAL |
AJWQ | Pilot Length | 0.0380 INCHES NOMINAL |
AAVL | Pilot Diameter | 0.4995 INCHES MINIMUM AND 0.5000 INCHES MAXIMUM |
ABPC | Undercut Width | 0.0620 INCHES NOMINAL |
ABPA | Undercut Diameter | 0.8370 INCHES NOMINAL |
AJSW | Zro Resistance In Ohms | 35.00 NOMINAL |
AJTA | Zrs Resistance In Ohms | 62.50 NOMINAL |
AJSY | Zso Resistance In Ohms | 10.40 NOMINAL |
AJTE | Zso-90 Resistance In Ohms | 9.10 NOMINAL |
AJTT | Stator Dc Resistance In Ohms | 10.90 NOMINAL |
CQTM | Terminal Location | REAR |
TTQY | Terminal Type And Quantity | 5 WIRE LEAD |