Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
3563100-3031 | 3 - Design Control Reference | 2 - Production Item | HONEYWELL INTERNATIONAL INC. | 96774 | |
3563100-3031 | 3 - Design Control Reference | 2 - Production Item | HONEYWELL INTERNATIONAL INC. | 96774 | |
10TR828-1771 | 5 - Replaced / Discontinued | 2 - Production Item | MOTION DEVICES TECHNOLOGY, INC. | 2X130 | |
10TR828-1771 | 5 - Replaced / Discontinued | 2 - Production Item | MOTION DEVICES TECHNOLOGY, INC. | 2X130 | |
1497023 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTL INC | 55972 | |
1497023-0000 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTL INC | 55972 | |
AY100TA50A1 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTL INC | 55972 | |
AY100TA50A1 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTERNATIONAL INC. | 96774 | |
1497023 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTL INC | 55972 | |
1497023-0000 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTL INC | 55972 | |
AY100TA50A1 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTL INC | 55972 | |
AY100TA50A1 | 5 - Replaced / Discontinued | 9 - No Longer Used | HONEYWELL INTERNATIONAL INC. | 96774 | |
1497023-0000 | 7 - Vendor Item Drawing Reference | 2 - Production Item | HONEYWELL INTERNATIONAL INC. | 96774 | |
1497023-0000 | 7 - Vendor Item Drawing Reference | 2 - Production Item | HONEYWELL INTERNATIONAL INC. | 96774 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5990 | 008281771 | A07800 | 02072 | X | 1 | A | N | U | 30 Aug 1967 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 3 | 2 | 6 | 9Z | D | 3563100-3031 | 96774 | |||||
5 | 2 | E | ZZ | 10TR828-1771 | 2X130 | |||||||
1 | 5 | 9 | 1 | TX | B | 1497023 | 55972 | |||||
1 | 5 | 9 | 1 | TX | B | 1497023-0000 | 55972 | |||||
1 | 5 | 9 | 1 | TX | B | AY100TA50A1 | 55972 | |||||
4 | 5 | 9 | 5 | ZZ | B | AY100TA50A1 | 96774 | |||||
7 | 2 | 5 | ZZ | 1497023-0000 | 96774 |
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
DLIS-K, Battle Creek, MI 49037-3084
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
The reference number is represented by engineering data other than an engineering drawing. The data is available for unlimited use and will be furnished by the activity identified by the RNAAC upon request.
USA
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Columbus, Columbus, OH 43218
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
C | KA | 6 | 6 Sep 1971 |
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
Naval Air Systems Command, Washington, DC 20360
Item is inactive (no recorded Primary/Secondary Inventory Control Activity (PICA/SICA)). File data coded KFD is forwarded.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TX | 593 | Z | 9 | A | V | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI |
Defense Supply Center Columbus, Columbus, OH 43218
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 51 | 1 | AAA | 0.2 lbs | 0.001 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | 00 | NA | X | D3 | DO | 03 | E | Q | U |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
No requirement
PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
Any suitable fiber box included in this table may be used (see J.4.9.1).
Mehod 50
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping containers in a manner that will ensure safe transportation at the lowest rate to the point of delivery and shall meet, as a minimum, the requirements of the following rules and regulations, as applicable to the mode(s) of transportation to be utilized: (a) Postal Regulations (b) Department of Transportation Regulations (c) Civil Air Regulations (d) Uniform Freight Classification Rules (e) National Motor Freight Classification Rules (f) American Truckers' Association Rules (g) Other applicable carriers' rules (h) Military Air Regulations for dangerous materials Consolidation of Shipments. All exterior packs of 1.5 cubic feet or less having no single dimension (length, width, height) exceeding 40 inches (and when the total number of such containers in any individual shipment exceeds 25), shall be consolidated, using flat pallets, box pallets, or containers as the consolidating media. Dangerous goods shall be prepared for shipment according to applicable Department of Transportation (DOT) regulations and international regulations in effect at time of shipment. Shipments by parcel post must comply with Postal Regulations.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AJVS | Actuator Friction Torque At Minus 55 Deg Celsius | 10000.0 MILLIMETER-MILLIGRAMS NOMINAL |
CTCW | Alignment Hole Bolt Circle Diameter | 0.6780 INCHES NOMINAL |
CRSY | Alignment Hole Depth | 0.0730 INCHES MAXIMUM |
AJVW | Alignment Hole Quantity | 3 |
AAFZ | Body Material | ALUMINUM ALLOY |
AJSL | Body Size | 10 |
AAQL | Body Style | STANDARD ROUND C |
ABKK | Flange Diameter | 0.9360 INCHES MINIMUM AND 0.9370 INCHES MAXIMUM |
ABKU | Flange Thickness | 0.0620 INCHES NOMINAL |
AJSS | Frequency In Hertz | 400.0 NOMINAL |
AJWX | Mounting Surface To Terminal End Distance | 1.2410 INCHES MAXIMUM |
CQXQ | Plus J Zro Reactance In Ohms | 3510.00 NOMINAL |
CRKL | Plus J Zrs Reactance In Ohms | 278.00 NOMINAL |
CRGZ | Plus J Zso Reactance In Ohms | 29.70 NOMINAL |
AJTS | Rotor Dc Resistance In Ohms | 309.00 NOMINAL |
AJST | Rotor Input Current Rating | 45.0 MILLIAMPERES MAXIMUM |
AJSV | Rotor Input Electrical Power Rating | 950.0 MILLIWATTS MAXIMUM |
AJSR | Rotor Input Voltage Rating In Volts | 115.0 NOMINAL |
ABWV | Shaft Diameter | 0.0895 INCHES MINIMUM SINGLE SHAFT AND 0.0900 INCHES MAXIMUM SINGLE SHAFT |
ABXF | Shaft Length | 0.3300 INCHES NOMINAL SINGLE SHAFT |
CRSJ | Shaft Type | ROUND SINGLE SHAFT |
AAVH | Shoulder Diameter | 0.8118 INCHES MINIMUM AND 0.8123 INCHES MAXIMUM |
AJWR | Shoulder Length | 0.0630 INCHES NOMINAL |
ABHP | Overall Length | 1.6210 INCHES MAXIMUM |
AJVF | Phase Shift Angle In Deg | 4.700 INPUT TO OUTPUT NOMINAL |
AAVL | Pilot Diameter | 0.4995 INCHES MINIMUM AND 0.5000 INCHES MAXIMUM |
AJWQ | Pilot Length | 0.0380 INCHES NOMINAL |
AJVV | Torque Gradient Per Angular Deg | 3200.0 MILLIMETER-MILLIGRAMS MINIMUM |
ABPA | Undercut Diameter | 0.8350 INCHES MINIMUM AND 0.8400 INCHES MAXIMUM |
ABPC | Undercut Width | 0.0620 INCHES NOMINAL |
AJTA | Zrs Resistance In Ohms | 707.00 NOMINAL |
AJSY | Zso Resistance In Ohms | 6.54 NOMINAL |
AJSW | Zro Resistance In Ohms | 591.00 NOMINAL |
AJTT | Stator Dc Resistance In Ohms | 4.66 NOMINAL |
CQTM | Terminal Location | REAR |
TTQY | Terminal Type And Quantity | 5 WIRE LEAD |