5990-01-016-1212

RESOLVER,ELECTRICAL


5990-01-016-1212 (5990010161212, 010161212)
Part Number (1 listing): SSH20E2A001
Summary

FSG 59 / FSC 5990

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 4 Feb 1976

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5990-01-016-1212 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
SSH20E2A0013 - Design Control Reference2 - Production ItemMOOG INC.  99932    CAGE 99932  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5990-01-016-1212 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595990010161212A0780022966X46ANU4 Feb 1976
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5990

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Synchros and Resolvers

010161212

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5990-01-016-1212

A07800

Federal Item Identification Guide (FIIG_4065)

22966

Item Naming Code (INC_4080)

4 Feb 1976

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

6

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG may exist, but it has previously been established and documented that industry refuses to provide the technical data sufficient for preparation on a full descriptive method item identification based on policy, restricted or proprietary data rights, nonexistence of technical data, etc.

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5990-01-016-1212 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5990-01-016-1212 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3229ZSSH20E2A001  99932   CAGE/99932
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5990-01-016-1212 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
59704 Feb 1976
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

4 Feb 1976

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5990-01-016-1212 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
87Q593Z9AHZW062120Z34760GENERATORS-MOTORS-PARTS-NOI1
Code Definitions

87

Originating Activity Code (ORIG_ACTY_CD_4210)


NASA Wallops Flight Center, Wallops Island, VA 23337-5099

Q

Less Than Carload (LCL_CD_2760)


70

593

Water Commodity Code (WRT_CMDTY_CD_9275)


Motors and Parts, (machinery and parts), (less than 35 feet)

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

W

Less Than Truckload (CLAS_RTNG_CD_2770)


Variable Rating

062120

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

Z

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34760

Uniform Freight Classification (UFC_CD_MODF_3040)

GENERATORS-MOTORS-PARTS-NOI

Freight Description (FRT_DESC_4020)

1 Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5990-01-016-1212 Submit RFQ
MRCDecoded RequirementClear Text Reply
AJVLElectrical Error Angular Range In Minutes-6.0/+6.0
ABPMBody Diameter1.7500 INCHES NOMINAL
CRMRBody Thru-Hole Diameter0.4687 INCHES NOMINAL
AJSLBody Size7
AAQLBody StylePICK-OFF A
AHCGMaximum Temp Rise40.0 DEG CELSIUS
CQXQPlus J Zro Reactance In Ohms1170.00 NOMINAL
CRGZPlus J Zso Reactance In Ohms965.00 NOMINAL
AJTSRotor Dc Resistance In Ohms29.00 NOMINAL
AJSTRotor Input Current Rating21.5 MILLIAMPERES NOMINAL
AJSVRotor Input Electrical Power Rating144.0 MILLIWATTS NOMINAL
AJSRRotor Input Voltage Rating In Volts26.0 NOMINAL
ABHPOverall Length0.3900 INCHES NOMINAL
AJVFPhase Shift Angle In Deg1.300 INPUT TO OUTPUT NOMINAL
AJSWZro Resistance In Ohms310.00 NOMINAL
AJSYZso Resistance In Ohms260.00 NOMINAL
AJTTStator Dc Resistance In Ohms24.00 NOMINAL
AJSPStator Input Current Rating26.0 MILLIAMPERES NOMINAL
AJSQStator Input Electrical Power Rating176.0 MILLIWATTS NOMINAL
AJSNStator Input Voltage Rating In Volts26.0 NOMINAL
TTQYTerminal Type And Quantity8 WIRE LEAD


Back to Top