5995-00-007-8962

CABLE ASSEMBLY,RADIO FREQUENCY


5995-00-007-8962 (5995000078962, 000078962)
Part Number (1 listing): 7011-7260-23
Summary

FSG 59 / FSC 5995

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 12 Jul 1972

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5995-00-007-8962 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
7011-7260-233 - Design Control Reference2 - Production ItemDRS ICAS, LLC  12115    CAGE 12115  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5995-00-007-8962 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595995000078962A077A000886X1ANS12 Jul 1972
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5995

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Cable, Cord, and Wire Assemblies: Communication Equipment

000078962

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5995-00-007-8962

A077A0

Federal Item Identification Guide (FIIG_4065)

00886

Item Naming Code (INC_4080)

12 Jul 1972

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.


FLIS - SEG B - MOE RULE DATA | NSN 5995-00-007-8962 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
FXGGFXCX00ZSX1 May 2006
Code Definitions

0

Acquisition Method Code (AMC_2871)


Not Established

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

SX

Item Management Coding Activity (IMC_ACTY_2748)


Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043


FLIS - SEG C - REFERENCE NUMBER | NSN 5995-00-007-8962 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
3322SBD7011-7260-23  12115   CAGE/12115
Code Definitions

3

Reference Number Format Code (RNFC_2920)


Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5995-00-007-8962 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
598028 Apr 2010
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

98

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

28 Apr 2010

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5995-00-007-8962 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TA743Z9AHZP061130X34350CABLE-ASSEMBLY
Code Definitions

TA

Originating Activity Code (ORIG_ACTY_CD_4210)


Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609

743

Water Commodity Code (WRT_CMDTY_CD_9275)


Electrical Cable

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061130

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34350

Uniform Freight Classification (UFC_CD_MODF_3040)

CABLE-ASSEMBLY

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5995-00-007-8962 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DFSMSVU1NEA0
DSSMSJU1EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

V

Acquisition Advice Code (AAC_2507)


TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.

U

Controlled Item Inventory Code (CIIC_2863)


Unclassified

1

Quantity Unit Pack (QUP_6106)


1

N

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

J

Acquisition Advice Code (AAC_2507)


NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5995-00-007-8962 Submit RFQ
MRCDecoded RequirementClear Text Reply
AMQNConductor Quantity1
CXCWConductor FormSOLID SINGLE CONDUCTOR
MATTMaterialSTEEL 1ST POSITION CONDUCTOR SINGLE CONDUCTOR
MATTMaterialPLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
MATTMaterialCOPPER 2ND POSITION CONDUCTOR SINGLE CONDUCTOR
MATTMaterialCOPPER ALLOY 2ND POSITION TUBE SINGLE CONDUCTOR
MATTMaterialSILVER 3RD POSITION COVER SINGLE CONDUCTOR
MDCLMaterial Document And ClassificationQQ-W-345 FED SPEC ALL MATERIAL RESPONSES 1ST POSITION CONDUCTOR SINGLE CONDUCTOR
MDCLMaterial Document And ClassificationMIL-C-17 MIL SPEC SINGLE MATERIAL RESPONSE 2ND POSITION TUBE SINGLE CONDUCTOR
SFTTSurface TreatmentSILVER CORE CONDUCTOR SINGLE CONDUCTOR
CXDCRound Conductor Size19 AWG SINGLE CONDUCTOR
CXDQConductor Arrangement And Quantity1 COAXIAL
AAPPElectrical Resistance50.00 OHMS IMPEDANCE
AAGRCross-Sectional Shape StyleROUND
ADVLCross Section Outside Diameter0.141 INCHES NOMINAL
AKRZTermination TypeCONNECTOR PLUG BOTH ENDS SINGLE CONDUCTOR
CXGGTerminal Manufacturer Identifying Reference Number2001-5031 1ST END SINGLE CONDUCTOR
CXGGTerminal Manufacturer Identifying Reference Number2001-5031 2ND END SINGLE CONDUCTOR
CXGNTerminal Commercial And Government Entity Code26805 BOTH ENDS SINGLE CONDUCTOR


Back to Top
Back to Top