Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
8190000346-3 | 3 - Design Control Reference | 2 - Production Item | NAVCOM DEFENSE ELECTRONICS, INC. | 57057 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5995 | 001075478 | A077A0 | 00886 | X | M | 9 | B | N | S | 2 Aug 1968 |
Cable, Cord, and Wire Assemblies: Communication Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item contains silver.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZG01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZR01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 1 | KE | 8190000346-3 | 57057 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Naval ICP, Philadelphia, PA 19111
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 1 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KE | J | 658 | Z | 9 | A | H | Z | J | 061320 | X | 34415 | COAXIAL-TRANSMISSION-LINE-FITTINGS | 1 |
Naval ICP, Philadelphia, PA 19111
100.2
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
Naval Inventory Control Point, Philadelphia, PA 19111-5098
DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED. Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AAPP | Electrical Resistance | 50.00 OHMS IMPEDANCE |
CXDQ | Conductor Arrangement And Quantity | 1 COAXIAL |
CXCW | Conductor Form | STRANDED SINGLE CONDUCTOR |
ADVL | Cross Section Outside Diameter | 0.080 INCHES NOMINAL |
AAGR | Cross-Sectional Shape Style | ROUND |
AMQN | Conductor Quantity | 1 |
MATT | Material | COPPER ALLOY 2ND POSITION SHIELD BRAID, METALLIC SINGLE CONDUCTOR |
MATT | Material | COPPER 2ND POSITION CONDUCTOR SINGLE CONDUCTOR |
MATT | Material | PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR |
MATT | Material | PLASTIC POLYTETRAFLUOROETHYLENE 4TH POSITION JACKET SINGLE CONDUCTOR |
MATT | Material | SILVER 3RD POSITION COATING SINGLE CONDUCTOR |
MATT | Material | STEEL 1ST POSITION CONDUCTOR SINGLE CONDUCTOR |
AAJU | Overall Length | 8.125 INCHES |
CXDG | Strand Awg Size Per Conductor | 37 SINGLE CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 SINGLE CONDUCTOR |
STYL | Style Designator | INTERNAL ANGLE CONNECTOR AND STRIPPED |
SFTT | Surface Treatment | SILVER CORE CONDUCTOR SINGLE CONDUCTOR |
CXGN | Terminal Commercial And Government Entity Code | 82260 2ND END SINGLE CONDUCTOR |
CXGG | Terminal Manufacturer Identifying Reference Number | 1199900770 2ND END ALL CONDUCTORS |
AKRZ | Termination Type | CONNECTOR EXTERNAL ANGLE 2ND END SINGLE CONDUCTOR |
AKRZ | Termination Type | STRIPPED 1ST END SINGLE CONDUCTOR |