5995-00-164-6704

CABLE ASSEMBLY,SPECIAL PURPOSE,ELECTRICAL


5995-00-164-6704 (5995001646704, 001646704)
Part Number (1 listing): SC-D-2826
Summary

FSG 59 / FSC 5995

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1961

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5995-00-164-6704 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
SC-D-28263 - Design Control Reference1 - Incomplete Part NumberUS ARMY COMMUNICATIONS &  80063    CAGE 80063  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5995-00-164-6704 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595995001646704A077A000782X49ANA1 Jan 1961
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5995

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Cable, Cord, and Wire Assemblies: Communication Equipment

001646704

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5995-00-164-6704

A077A0

Federal Item Identification Guide (FIIG_4065)

00782

Item Naming Code (INC_4080)

1 Jan 1961

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.


FLIS - SEG B - MOE RULE DATA | NSN 5995-00-164-6704 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU
ZU011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5995-00-164-6704 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
1312CXDSC-D-2826  80063   CAGE/80063
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

CX

Reference Number Action Activity Code (RNAAC_2900)


Defense Supply Center Richmond, Richmond, VA 23297-5000

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG G - FREIGHT DATA | NSN 5995-00-164-6704 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
658Z9AHZJ061320X34415COAXIAL-TRANSMISSION-LINE-FITTINGS
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

J

Less Than Truckload (CLAS_RTNG_CD_2770)


100.2

061320

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34415

Uniform Freight Classification (UFC_CD_MODF_3040)

COAXIAL-TRANSMISSION-LINE-FITTINGS

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5995-00-164-6704 Submit RFQ
MRCDecoded RequirementClear Text Reply
AMQNConductor Quantity6
CXCWConductor FormSTRANDED ALL CONDUCTORS
MATTMaterialCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATTMaterialRUBBER NATURAL 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATTMaterialRUBBER NATURAL 1ST POSITION JACKET CABLE
MDCLMaterial Document And ClassificationMIL-I-3930,TYPE IS MIL SPEC SINGLE MATERIAL RESPONSE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
BLNZStrand Quantity Per Conductor19 ALL CONDUCTORS
STYLStyle DesignatorINTERNAL ANGLE CONNECTOR AND STRIPPED
AAJUOverall Length3.417 FEET
AAGRCross-Sectional Shape StyleROUND
ADVLCross Section Outside Diameter0.490 INCHES NOMINAL
CXGGTerminal Manufacturer Identifying Reference NumberPL-114 1ST END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference NumberSCA4412 2ND END ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code80063 1ST END ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code80063 BOTH ENDS ALL CONDUCTORS
FEATSpecial FeaturesINCL 9 IN. LG NO. 18 AWG HOOK-UP WIRE SOLDERED TO SHIELD ON 2ND END AND TERMINATED W/1 SIG TERMINAL DWG NO. SCA4412


Back to Top
Back to Top