5995-00-284-9396

CABLE ASSEMBLY,TELEPHONE


5995-00-284-9396 (5995002849396, 002849396)
Part Number (1 listing): CX2794U
Summary

FSG 59 / FSC 5995

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 1 Jan 1961

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5995-00-284-9396 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
CX2794U3 - Design Control Reference1 - Incomplete Part NumberJOINT ELECTRONICS TYPE DESIGNATION  80058    CAGE 80058  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5995-00-284-9396 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595995002849396A077A000098NN9ANU1 Jan 1961
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5995

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Cable, Cord, and Wire Assemblies: Communication Equipment

002849396

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5995-00-284-9396

A077A0

Federal Item Identification Guide (FIIG_4065)

00098

Item Naming Code (INC_4080)

1 Jan 1961

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

N

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).

N

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference - Descriptive Item Identification (Type 1B Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5995-00-284-9396 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU011 Apr 1991
Code Definitions

FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5995-00-284-9396 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
2CX014 Mar 1974
Code Definitions

2

Item Standardization Code (ISC_2650)


An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.

CX

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


Defense Supply Center Richmond, Richmond, VA 23297-5000

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

14 Mar 1974

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5995-00-284-9396 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5995-00-284-9396 Submit RFQ
MRCDecoded RequirementClear Text Reply
CXDQConductor Arrangement And Quantity5 PARALLEL PAIR
AAGRCross-Sectional Shape StyleROUND
AMQNConductor Quantity10
MATTMaterialRUBBER NATURAL 1ST POSITION JACKET CABLE
MATTMaterialRUBBER NATURAL 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
MDCLMaterial Document And ClassificationMIL-I-3930,TYPE IS MIL SPEC SINGLE MATERIAL RESPONSE 1ST POSITION JACKET CABLE
MDCLMaterial Document And ClassificationMIL-I-3930,TYPE IS MIL SPEC SINGLE MATERIAL RESPONSE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
ZZZYReference Number Differentiating CharacteristicsAS DIFFERENTIATED BY LG OVERALL
AAJUOverall Length25.500 FEET
STYLStyle DesignatorDUAL RECEPTACLE
CXGNTerminal Commercial And Government Entity Code77280 1ST END ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code77280 2ND END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference Number10-64618-1P 1ST END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference Number10-64618-1S 2ND END ALL CONDUCTORS
AKRZTermination TypeCONNECTOR PLUG BOTH ENDS ALL CONDUCTORS


Back to Top
Back to Top