Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
E4862-99 | 3 - Design Control Reference | 2 - Production Item | DCX-CHOL ENTERPRISES, INC. | 30463 | ![]() |
10556099 | 7 - Vendor Item Drawing Reference | 2 - Production Item | US ARMY ARDEC RDECOM | 19200 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5995 | 004002566 | A077A0 | 00485 | X | K | A | N | S | 0 | 28 Feb 1969 |
Cable, Cord, and Wire Assemblies: Communication Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item contains silver.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 6 | BF | D | E4862-99 | 30463 | ![]() | ||||
3 | 7 | 2 | 1 | BF | D | 10556099 | 19200 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | BF | 0 | 22 Jan 1970 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
U.S. Army Armament and Chemical Acquisition and, Logistics Activity, Rock Island, IL 61299-6000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BG | Q | 743 | Z | 9 | A | H | Z | P | 061130 | X | 34350 | CABLE-ASSEMBLY | 1 |
RDECOM-ECBC-RI Rock Island, IL 61299
70
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AWTB | Accessory Wire Type And Quantity | 1 GROUND |
CXDQ | Conductor Arrangement And Quantity | 3 SINGLES |
CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
ADVL | Cross Section Outside Diameter | 0.520 INCHES NOMINAL |
AAGR | Cross-Sectional Shape Style | ROUND |
AMQN | Conductor Quantity | 3 |
MDCL | Material Document And Classification | QQ-W-343,SOFT FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXGW | Individual Conductor Length | 1.513 INCHES NOMINAL 1ST END ALL CONDUCTORS |
CXGW | Individual Conductor Length | 1.531 INCHES NOMINAL 2ND END ALL CONDUCTORS |
CXDC | Round Conductor Size | 16 AWG ALL CONDUCTORS |
FEAT | Special Features | 3 TAGS |
AAJU | Overall Length | 93.000 INCHES |
CXDG | Strand Awg Size Per Conductor | 29 ALL CONDUCTORS |
BLNZ | Strand Quantity Per Conductor | 19 ALL CONDUCTORS |
STYL | Style Designator | JACK AND EXTERNAL CONNECTOR |
SFTT | Surface Treatment | SILVER CORE CONDUCTOR ALL CONDUCTORS |
CXGN | Terminal Commercial And Government Entity Code | 96906 1ST END ALL CONDUCTORS |
CXGN | Terminal Commercial And Government Entity Code | 19200 2ND END ALL CONDUCTORS |
CXGG | Terminal Manufacturer Identifying Reference Number | 11727724 2ND END ALL CONDUCTORS |
CXGG | Terminal Manufacturer Identifying Reference Number | MS3126E-12-3-S 1ST END ALL CONDUCTORS |
AKRZ | Termination Type | CONNECTOR PLUG BOTH ENDS ALL CONDUCTORS |