Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
SMD90202 | 3 - Design Control Reference | 1 - Incomplete Part Number | US ARMY COMMUNICATIONS & | 80063 | ![]() |
CX12208U3FT | 3 - Design Control Reference | 2 - Production Item | JOINT ELECTRONICS TYPE DESIGNATION | 80058 | ![]() |
DL-SM-A-690228/3FT | 3 - Design Control Reference | 2 - Production Item | US ARMY COMMUNICATIONS & | 80063 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5995 | 004968544 | A077A0 | 00485 | X | 4 | 9 | B | N | A | 8 Oct 1969 |
Cable, Cord, and Wire Assemblies: Communication Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive Item Identification (Type 1 Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A918 | A178 | 1 | G | Z | CL | CL | 1 May 2005 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 1 | 5 | CL | D | SMD90202 | 80063 | ![]() | ||||
3 | 3 | 2 | 4 | CL | D | CX12208U3FT | 80058 | ![]() | ||||
4 | 3 | 2 | 5 | CL | A | DL-SM-A-690228/3FT | 80063 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.
Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
C | CX | 0 | 1 Dec 1974 |
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CL | 743 | Z | 9 | A | H | Z | P | 061130 | X | 34350 | CABLE-ASSEMBLY |
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AMQN | Conductor Quantity | 2 |
CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATT | Material | RUBBER BUTADIENE-STYRENE CLASS SBR 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
SFTT | Surface Treatment | TIN CORE CONDUCTOR ALL CONDUCTORS |
CXDC | Round Conductor Size | 12 AWG ALL CONDUCTORS |
BLNZ | Strand Quantity Per Conductor | 65 ALL CONDUCTORS |
CXDG | Strand Awg Size Per Conductor | 30 ALL CONDUCTORS |
CXDQ | Conductor Arrangement And Quantity | 2 SINGLES |
CXFK | Voltage Rating | 600.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS |
STYL | Style Designator | EXTERNAL ANGLE CONNECTOR AND CLIP |
AAJU | Overall Length | 3.000 FEET |
AAGR | Cross-Sectional Shape Style | ROUND |
ADVL | Cross Section Outside Diameter | 0.480 INCHES NOMINAL |
CXGG | Terminal Manufacturer Identifying Reference Number | MS3101R22-2S 1ST END ALL CONDUCTORS |
CXGG | Terminal Manufacturer Identifying Reference Number | PC ITEM 4 2ND END ALL CONDUCTORS |
CXGN | Terminal Commercial And Government Entity Code | 96906 1ST END ALL CONDUCTORS |
CXGN | Terminal Commercial And Government Entity Code | 81348 2ND END ALL CONDUCTORS |
ZZZV | Fsc Application Data | CABLE ASSEMBLY,POWER,ELECTRICAL,COMMUNICATION |