Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE |
---|
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5995 | 005426565 | A077A0 | 04581 | X | 1 | B | N | U | 1 Jan 1963 |
Cable, Cord, and Wire Assemblies: Communication Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU01 | 1 Apr 1991 |
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
C | CX | 0 | 20 May 1969 |
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
J | 658 | Z | 5 | A | H | Y | J | 062360 | X | 34890 | LEADS-LEAD-WIRES-ELEC-ARTICLE-ETC | 1 |
100.2
Electical Appliances, Small
No special type of cargo code applicable
Protected (Pilferable)
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Protected cargo, other than above, including sensitive cargo requiring hand-to-hand receipt and/or security precautions.
A Variation Exists. NMFC and UFCC Do Not Match. Activity needs to determine which of these descriptions apply.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CXCW | Conductor Form | STRANDED SINGLE CONDUCTOR |
AAGR | Cross-Sectional Shape Style | ROUND |
MATT | Material | COPPER CORE CONDUCTOR SINGLE CONDUCTOR |
MATT | Material | RUBBER NATURAL CORE PRIMARY INSULATION SINGLE CONDUCTOR OR RUBBER SYNTHETIC CORE PRIMARY INSULATION SINGLE CONDUCTOR |
AXBQ | Lead Overall Length | 102.000 INCHES NOMINAL |
FEAT | Special Features | CONDUCTOR MANUFACTURER IDENTIFYING REFERENCE NUMBER: MIL-C-3432 TYPE CO-01RGF1/4/0500, CAGE 81348; TERMINAL LUGS ON EACH END MARKED W/A PLUS SING AND RED INSULATED SLEEVE ON CABLE ENDS |
CXFK | Voltage Rating | 600.0 DC MAXIMUM RATED WORKING VOLTAGE SINGLE CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 4 SINGLE CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 1 SINGLE CONDUCTOR |
CXGN | Terminal Commercial And Government Entity Code | 80063 BOTH ENDS SINGLE CONDUCTOR |
CXGG | Terminal Manufacturer Identifying Reference Number | SC-A-73626 BOTH ENDS SINGLE CONDUCTOR |
AKRZ | Termination Type | TERMINAL LUG BOTH ENDS SINGLE CONDUCTOR |