Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
CG550U | 3 - Design Control Reference | 1 - Incomplete Part Number | JOINT ELECTRONICS TYPE DESIGNATION | 80058 | ![]() |
16-1030 | 5 - Replaced / Discontinued | 9 - No Longer Used | PRECISION INDUSTRIES INC | 97749 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5995 | 005486490 | A077A0 | 00886 | X | N | 9 | B | N | S | 0 | 1 Jan 1963 |
Cable, Cord, and Wire Assemblies: Communication Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference - Descriptive Item Identification (Type 1B Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item contains silver.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Jun 2003 | |||||||||||||||||||||||||||||
N9BG | N9GD | 3 | H | Z | HD | HD | 1 May 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 31 Jan 1966 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
743 | Z | 9 | A | H | Z | P | 061130 | X | 34350 | CABLE-ASSEMBLY |
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AAPP | Electrical Resistance | 52.00 OHMS IMPEDANCE |
HUES | Color | WHITE 1ST POSITION COVER SINGLE CONDUCTOR |
CXDQ | Conductor Arrangement And Quantity | 1 SINGLES |
CXCW | Conductor Form | STRANDED SINGLE CONDUCTOR |
ADVL | Cross Section Outside Diameter | 0.420 INCHES NOMINAL |
AAGR | Cross-Sectional Shape Style | ROUND |
ZZZV | Fsc Application Data | FREQUENCY METER |
AMQN | Conductor Quantity | 1 |
MATT | Material | COPPER 1ST POSITION CONDUCTOR SINGLE CONDUCTOR |
MATT | Material | COPPER 2ND POSITION SHIELD BRAID, METALLIC SINGLE CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR |
MATT | Material | PLASTIC VINYL 3RD POSITION JACKET SINGLE CONDUCTOR |
MATT | Material | SILVER 2ND POSITION CONDUCTOR SINGLE CONDUCTOR |
ZZZY | Reference Number Differentiating Characteristics | OVERALL LENGTH |
CXDC | Round Conductor Size | 10 AWG SINGLE CONDUCTOR |
AAJU | Overall Length | 65.000 INCHES |
CXDG | Strand Awg Size Per Conductor | 21 SINGLE CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 SINGLE CONDUCTOR |
STYL | Style Designator | STRIPPED AND LUG |
CXGN | Terminal Commercial And Government Entity Code | 80058 BOTH ENDS SINGLE CONDUCTOR |
CXGG | Terminal Manufacturer Identifying Reference Number | 52A/U 2ND END SINGLE CONDUCTOR |
CXGG | Terminal Manufacturer Identifying Reference Number | UG-21/U 1ST END SINGLE CONDUCTOR |
AKRZ | Termination Type | CONNECTOR PLUG BOTH ENDS SINGLE CONDUCTOR |