Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE |
---|
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5995 | 005568505 | A077A0 | 00485 | X | 1 | B | N | U | 1 Jan 1963 |
Cable, Cord, and Wire Assemblies: Communication Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BG | N9GD | 0 | 0 | Z | HD | HD | 1 May 2005 |
Not Established
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 15 Dec 1974 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
743 | Z | 9 | A | H | Z | P | 061130 | X | 34350 | CABLE-ASSEMBLY |
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AMQN | Conductor Quantity | 2 |
CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATT | Material | RUBBER SYNTHETIC 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
CXDC | Round Conductor Size | 16 AWG ALL CONDUCTORS |
BLNZ | Strand Quantity Per Conductor | 26 ALL CONDUCTORS |
CXDG | Strand Awg Size Per Conductor | 30 ALL CONDUCTORS |
CXDQ | Conductor Arrangement And Quantity | 2 SINGLES |
CXFK | Voltage Rating | 600.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS |
STYL | Style Designator | JACK AND EXTERNAL CONNECTOR |
AAJU | Overall Length | 5.333 FEET |
AAGR | Cross-Sectional Shape Style | ROUND |
AKRZ | Termination Type | CONNECTOR PLUG BOTH ENDS ALL CONDUCTORS |
CXGG | Terminal Manufacturer Identifying Reference Number | AM-5935-149-4193 1ST END ALL CONDUCTORS |
CXGG | Terminal Manufacturer Identifying Reference Number | AN3106-B-16S-5S 2ND END ALL CONDUCTORS |
CXGN | Terminal Commercial And Government Entity Code | 81348 1ST END ALL CONDUCTORS |
CXGN | Terminal Commercial And Government Entity Code | 81349 2ND END ALL CONDUCTORS |
FEAT | Special Features | CABLE,MIL-C-915A,TYPE NO.DHOF-3 |