Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
103025 | 3 - Design Control Reference | 2 - Production Item | EXELIS INC. | 24930 | ![]() |
114737 | E - Replace Reference Number | 8 - Replacement NSN | BAE SYSTEMS INFORMATION AND | 80249 | ![]() |
528892 | E - Replace Reference Number | 8 - Replacement NSN | RAYTHEON COMPANY | 05869 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5995 | 009857707 | A077A0 | 00886 | X | 1 | A | N | U | 1 Jan 1962 |
Cable, Cord, and Wire Assemblies: Communication Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YB01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
A918 | A178 | 1 | G | Z | CD | CL | 1 May 2006 | |||||||||||||||||||||||
FXGG | FXCX | 1 | G | Z | SX | 1 May 2006 | ||||||||||||||||||||||||
N9BG | N9GD | 1 | G | Z | HD | HD | 1 May 2006 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Replaced Reference Number. A manufacturerÆs part number, government specification/standard or other design control reference number that is superseded, discontinued or replaced resulting from a cancel-use action on a NSN which was recorded with ISC 3 or E. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
A non-item-identifying reference number that is added to a replacement NSN as a result of a cancel-use action on a NSN recorded with ISC 3 or E. It is used to indentify the original item of supply/replaced item. This reference number is automatically moved and this code is automatically assigned, do not submit for cataloging purposes.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.
USA
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 9Z | 0 | 1 Nov 2013 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-K, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
743 | Z | 9 | A | H | Z | P | 061130 | X | 34350 | CABLE-ASSEMBLY |
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
No QUP
ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
ARMY: When repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level; MARINE CORPS: Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level; NAVY: Field Level Reparables
ARMY: If condemned or uneconomically repairable, then dispose at direct support (ds) level; DLA: This item has been reviewed and a determination made that the item can be restored to a serviceable condition from an unserviceable condition at the organizational/field level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at the third echelon level; NAVY: (1) Fast-Moving 1I Cog Forms (2) Non-Perishable Provisions
Department of the Army
Department of the Air Force
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AMQN | Conductor Quantity | 1 |
CXCW | Conductor Form | STRANDED SINGLE CONDUCTOR |
MATT | Material | COPPER CORE CONDUCTOR SINGLE CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR |
MATT | Material | COPPER 2ND POSITION SHIELD BRAID, METALLIC SINGLE CONDUCTOR |
MATT | Material | RESIN SYNTHETIC 3RD POSITION JACKET SINGLE CONDUCTOR |
MDCL | Material Document And Classification | QQ-W-343 FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR |
MDCL | Material Document And Classification | L-P-390,TYPE 2,CLASS L,GRADE 7 MIL SPEC SINGLE MATERIAL RESPONSE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR |
MDCL | Material Document And Classification | QQ-W-343 FED SPEC SINGLE MATERIAL RESPONSE 2ND POSITION SHIELD BRAID, METALLIC SINGLE CONDUCTOR |
CXDC | Round Conductor Size | 20 AWG SINGLE CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 SINGLE CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 33 SINGLE CONDUCTOR |
CXDQ | Conductor Arrangement And Quantity | 1 COAXIAL |
AAPP | Electrical Resistance | 50.00 OHMS IMPEDANCE |
STYL | Style Designator | INTERNAL AND EXTERNAL CONNECTOR |
AAJU | Overall Length | 9.500 INCHES |
AAGR | Cross-Sectional Shape Style | ROUND |
ADVL | Cross Section Outside Diameter | 0.195 INCHES NOMINAL |
AKRZ | Termination Type | CONNECTOR PLUG BOTH ENDS SINGLE CONDUCTOR |
CXGG | Terminal Manufacturer Identifying Reference Number | M39012/16-0101 1ST END SINGLE CONDUCTOR |
CXGN | Terminal Commercial And Government Entity Code | 81349 BOTH ENDS SINGLE CONDUCTOR |
FEAT | Special Features | MIL-C-17/28A,TYPE NO. RG-58C/U |
AGAV | End Item Identification | AN/SPS-52 SEARCH RADAR |