Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
CG-1333A/U3FT6IN | 3 - Design Control Reference | 2 - Production Item | US ARMY COMMUNICATIONS & | 80063 | ![]() |
SC-D-75401-3FT6IN | 3 - Design Control Reference | 2 - Production Item | US ARMY COMMUNICATIONS & | 80063 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5995 | 009857965 | A077A0 | 00886 | X | 1 | A | N | A | 1 Jan 1960 |
Cable, Cord, and Wire Assemblies: Communication Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZS01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZU01 | 1 Aug 1995 | |||||||||||||||||||||||||||||
WB01 | 1 Feb 2005 | |||||||||||||||||||||||||||||
ZW01 | 1 Oct 2009 |
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | 4 | CX | CG-1333A/U3FT6IN | 80063 | ![]() | ||||||
3 | 2 | 5 | CX | SC-D-75401-3FT6IN | 80063 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.
Defense Supply Center Richmond, Richmond, VA 23297-5000
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
1 | CX | 0 | 3 | CX | 0 | 7 Apr 1972 | 5995007522335 | 15 Mar 1972 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
658 | Z | 9 | A | H | Z | J | 061320 | X | 34415 | COAXIAL-TRANSMISSION-LINE-FITTINGS |
Electical Appliances, Small
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
100.2
No Variation. NMFC and UFCC Match.
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
A | P | ZZ | Z | 0.1 lbs | 0.015 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
ZZ | ZZ | ZZ | Z | ZZ | ZZ |
Packaging Data Record contains data that does not meet current MIL-STD-2073-1C/D formats
Primary Inventory Control Activity (PICA)
See J.4.1.b
Special Requirements - See specific instructions or drawings provided.
Special requirement – See specific instructions or drawings provided
Special requirements – see specific instructions or drawings provided
Special requirements. See specific instructions or drawings provided.
Special requirements-See specific instructions or drawings provided
Special requirement – See specific instructions or drawings provided.
Special requirement – See specific instructions or drawings provided.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AMQN | Conductor Quantity | 1 |
CXCW | Conductor Form | STRANDED SINGLE CONDUCTOR |
MATT | Material | COPPER CORE CONDUCTOR SINGLE CONDUCTOR |
CXDC | Round Conductor Size | 13 AWG SINGLE CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 SINGLE CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 21 SINGLE CONDUCTOR |
CXDQ | Conductor Arrangement And Quantity | 1 COAXIAL |
AAPP | Electrical Resistance | 50.00 OHMS IMPEDANCE |
STYL | Style Designator | INTERNAL CONNECTOR AND LUG |
AAJU | Overall Length | 3.500 FEET |
AAGR | Cross-Sectional Shape Style | ROUND |
ADVL | Cross Section Outside Diameter | 0.340 INCHES NOMINAL |
AKRZ | Termination Type | CONNECTOR PLUG 1ST END SINGLE CONDUCTOR |
AKRZ | Termination Type | LUG TERMINAL W/MOUNTING HOLE 2ND END SINGLE CONDUCTOR |
CXFM | Terminal Lug Aperture Size | 0.196 INCHES 2ND END SINGLE CONDUCTOR |
CXGG | Terminal Manufacturer Identifying Reference Number | M39012/02-0101 1ST END ALL CONDUCTORS |
CXGG | Terminal Manufacturer Identifying Reference Number | 3003-10 2ND END ALL CONDUCTORS |
CXGN | Terminal Commercial And Government Entity Code | 81349 1ST END SINGLE CONDUCTOR |
CXGN | Terminal Commercial And Government Entity Code | 16428 2ND END SINGLE CONDUCTOR |
CXGW | Individual Conductor Length | 2.625 INCHES NOMINAL 2ND END SINGLE CONDUCTOR |
FEAT | Special Features | RG-213/U CABLE |