5995-01-071-6332

CABLE ASSEMBLY,SPECIAL PURPOSE,ELECTRICAL


5995-01-071-6332 (5995010716332, 010716332)
Part Number (1 listing): 1274A95
Summary

FSG 59 / FSC 5995

DEMIL: A

DEMIL INT:

HMIC: N

Date Created: 13 Feb 1979

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5995-01-071-6332 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
1274A953 - Design Control Reference2 - Production ItemBAE SYSTEMS INFORMATION AND  72314    CAGE 72314  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5995-01-071-6332 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595995010716332A077A000782XKANU13 Feb 1979
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5995

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Cable, Cord, and Wire Assemblies: Communication Equipment

010716332

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5995-01-071-6332

A077A0

Federal Item Identification Guide (FIIG_4065)

00782

Item Naming Code (INC_4080)

13 Feb 1979

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

U

Precious Metals Indicator Code (PMIC_0802)


Precious Metal Content is unknown.


FLIS - SEG B - MOE RULE DATA | NSN 5995-01-071-6332 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Apr 1991
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5995-01-071-6332 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
1325CLA1274A95  72314   CAGE/72314
Code Definitions

1

Reference Number Format Code (RNFC_2920)


Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

CL

Reference Number Action Activity Code (RNAAC_2900)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

A

Reference Number Status Code (RNSC_2923)


Manufacturer and reference number are authorized for procurement. Under this reference number items can be procured only from the manufacturer identified by the NCAGE. NOTE: This code may only be used for reference numbers originating from manufacturers' standards or catalogs or for copyrighted drawing numbers.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5995-01-071-6332 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597013 Feb 1979
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

13 Feb 1979

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5995-01-071-6332 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
CL743Z9AHZP061130X34350CABLE-ASSEMBLY
Code Definitions

CL

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006

743

Water Commodity Code (WRT_CMDTY_CD_9275)


Electrical Cable

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

P

Less Than Truckload (CLAS_RTNG_CD_2770)


77.5

061130

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

34350

Uniform Freight Classification (UFC_CD_MODF_3040)

CABLE-ASSEMBLY

Freight Description (FRT_DESC_4020)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5995-01-071-6332 Submit RFQ
MRCDecoded RequirementClear Text Reply
HUESColorWHITE 1ST POSITION COVER ALL CONDUCTORS
CXCWConductor FormSTRANDED ALL CONDUCTORS
AMQNConductor Quantity36
CXDQConductor Arrangement And Quantity36 SINGLES
AAGRCross-Sectional Shape StyleFLAT
ADVNCross-Sectional Height0.030 INCHES NOMINAL
ADWHCross-Sectional Width2.812 INCHES NOMINAL
MATTMaterialCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATTMaterialPLASTIC POLYALKENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
CXDCRound Conductor Size22 AWG ALL CONDUCTORS
FEATSpecial Features2 CABLE MARKERS
AAJUOverall Length8.750 INCHES
CXDGStrand Awg Size Per Conductor34 ALL CONDUCTORS
BLNZStrand Quantity Per Conductor19 ALL CONDUCTORS
STYLStyle DesignatorINTERNAL AND EXTERNAL CONNECTOR
SFTTSurface TreatmentTIN 1ST POSITION CONDUCTOR ALL CONDUCTORS
ABJHTemp Rating-150.0 DEG CELSIUS
CXGNTerminal Commercial And Government Entity Code81349 1ST END ALL CONDUCTORS
CXGNTerminal Commercial And Government Entity Code81349 BOTH ENDS ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference NumberM24308/2-289 2ND END ALL CONDUCTORS
CXGGTerminal Manufacturer Identifying Reference NumberM55302/66-56M 1ST END ALL CONDUCTORS
AKRZTermination TypeCONNECTOR PLUG BOTH ENDS ALL CONDUCTORS


Back to Top
Back to Top