| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 30020-91 | 3 - Design Control Reference | 2 - Production Item | DRS SIGNAL SOLUTIONS, INC. | 14632 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5995 | 011284577 | A077A0 | 00886 | X | M | 9 | B | N | S | 21 Mar 1982 |
Cable, Cord, and Wire Assemblies: Communication Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item contains silver.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| N9BG | N9GD | 5 | H | Z | HD | HD | 1 May 2005 | |||||||||||||||||||||||
Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 2 | 5 | CX | 30020-91 | 14632 | | ||||||
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Defense Supply Center Richmond, Richmond, VA 23297-5000
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 21 Mar 1982 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CX | 743 | Z | 9 | A | H | Z | P | 061130 | X | 34350 | CABLE-ASSEMBLY |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Navy
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AAPP | Electrical Resistance | 50.00 OHMS IMPEDANCE |
| CXCW | Conductor Form | SOLID SINGLE CONDUCTOR |
| CXDQ | Conductor Arrangement And Quantity | 1 COAXIAL |
| ADVL | Cross Section Outside Diameter | 0.212 INCHES NOMINAL |
| AAGR | Cross-Sectional Shape Style | ROUND |
| AMQN | Conductor Quantity | 1 |
| MDCL | Material Document And Classification | MIL-C-17 FED SPEC SINGLE MATERIAL RESPONSE 2ND POSITION SHIELD BRAID, METALLIC SINGLE CONDUCTOR |
| MDCL | Material Document And Classification | MIL-C-17 MIL SPEC ALL MATERIAL RESPONSES 1ST POSITION CONDUCTOR SINGLE CONDUCTOR |
| MDCL | Material Document And Classification | MIL-C-17 MIL SPEC SINGLE MATERIAL RESPONSE 3RD POSITION SHIELD BRAID, METALLIC SINGLE CONDUCTOR |
| PMLC | Precious Material And Location | CONDUCTOR SILVER |
| PRMT | Precious Material | SILVER |
| PMWT | Precious Material And Weight | 0.040 SILVER GRAINS, TROY |
| CXDC | Round Conductor Size | 19 AWG SINGLE CONDUCTOR |
| AAJU | Overall Length | 1.042 FEET |
| FEAT | Special Features | M17/084-RG223 CABLE |
| STYL | Style Designator | INTERNAL ANGLE AND INTERNAL STRAIGHT CONNECTOR |
| ABJH | Temp Rating | -40.0 DEG CELSIUS AND 85.0 DEG CELSIUS |
| CXGN | Terminal Commercial And Government Entity Code | 80063 1ST END SINGLE CONDUCTOR |
| CXGN | Terminal Commercial And Government Entity Code | 81349 2ND END SINGLE CONDUCTOR |
| CXGG | Terminal Manufacturer Identifying Reference Number | M39012/20-0101 2ND END ALL CONDUCTORS |
| CXGG | Terminal Manufacturer Identifying Reference Number | UG1052/U 1ST END ALL CONDUCTORS |
| AKRZ | Termination Type | CONNECTOR EXTERNAL ANGLE 2ND END SINGLE CONDUCTOR |
| AKRZ | Termination Type | CONNECTOR RECEPTACLE 1ST END SINGLE CONDUCTOR |