| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 1629670 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON COMPANY | 05869 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5995 | 011576538 | A077A0 | 00886 | Y | K | A | N | S | 10 Jul 1983 |
Cable, Cord, and Wire Assemblies: Communication Equipment
The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item contains silver.
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZX01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
| A918 | A178 | 3 | H | Z | CD | CL | 1 Feb 2005 | |||||||||||||||||||||||
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
U.S. Army War Reserve Command, New Cumberland, PA 17070-5008
U.S. Army Communications-Electronics, Fort Monmouth, NJ 07703-5006
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 2 | A | CX | 1629670 | 05869 | | ||||||
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Richmond, Richmond, VA 23297-5000
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 10 Jul 1983 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CX | 743 | Z | 9 | A | H | Z | P | 061130 | X | 34350 | CABLE-ASSEMBLY |
Defense Supply Center Richmond, Richmond, VA 23297-5000
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
ARMY: Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. MARINE CORPS: Item requires special handling/or condemnation procedures because of specific reasons (i.e., precious metal content, high dollar value, critical material, or hazardous material). Refer to appropriate manuals/directives for specific instructions. NAVY: Field Activity Control Items
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Department of the Army
Defense Logistics Agency
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AAPP | Electrical Resistance | 50.00 OHMS IMPEDANCE |
| CXCW | Conductor Form | SOLID SINGLE CONDUCTOR |
| CXDQ | Conductor Arrangement And Quantity | 1 COAXIAL |
| CRTL | Criticality Code Justification | MATT |
| ADVL | Cross Section Outside Diameter | 0.141 INCHES NOMINAL |
| AAGR | Cross-Sectional Shape Style | ROUND |
| AMQN | Conductor Quantity | 1 |
| MDCL | Material Document And Classification | QQ-W-345 FED SPEC ALL MATERIAL RESPONSES 1ST POSITION CONDUCTOR ALL CONDUCTORS |
| MATT | Material | COPPER 2ND POSITION CONDUCTOR SINGLE CONDUCTOR |
| MATT | Material | COPPER 2ND POSITION TUBE SINGLE CONDUCTOR |
| MATT | Material | PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR |
| MATT | Material | STEEL 1ST POSITION CONDUCTOR SINGLE CONDUCTOR |
| PMLC | Precious Material And Location | CONDUCTOR SILVER |
| PRMT | Precious Material | SILVER |
| PMWT | Precious Material And Weight | 0.040 SILVER GRAINS, TROY |
| CXDC | Round Conductor Size | 19 AWG SINGLE CONDUCTOR |
| AAJU | Overall Length | 1.530 INCHES |
| FEAT | Special Features | RG402/U CABLE |
| SFTT | Surface Treatment | SILVER CORE CONDUCTOR SINGLE CONDUCTOR |
| CXGN | Terminal Commercial And Government Entity Code | 05869 BOTH ENDS SINGLE CONDUCTOR |
| CXGG | Terminal Manufacturer Identifying Reference Number | 713521-1 1ST END ALL CONDUCTORS |
| CXGG | Terminal Manufacturer Identifying Reference Number | 713521-1 2ND END ALL CONDUCTORS |
| AKRZ | Termination Type | CONNECTOR PLUG BOTH ENDS SINGLE CONDUCTOR |