Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
734227-3 | 3 - Design Control Reference | 9 - No Longer Used | DRS SUSTAINMENT SYSTEMS, INC. | 20418 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5995 | 014650504 | A077A0 | 00886 | Y | 1 | A | N | S | 0 | 20 May 1999 |
Cable, Cord, and Wire Assemblies: Communication Equipment
The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item contains silver.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BG | N1R5 | 3 | H | Z | GH | GG | KE | 1 Feb 2014 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Philadelphia, PA 19111û5098
Naval ICP, Philadelphia, PA 19111
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 9 | 5 | KE | 734227-3 | 20418 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
Naval ICP, Philadelphia, PA 19111
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 97 | 0 | 20 May 1999 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
KE | 743 | Z | 9 | A | H | Z | P | 061130 | X | 34350 | CABLE-ASSEMBLY |
Naval ICP, Philadelphia, PA 19111
Electrical Cable
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
77.5
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Unclassified
No QUP
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AAPP | Electrical Resistance | 50.0 OHMS IMPEDANCE |
AGAV | End Item Identification | AW9 OPTS; CHASSIS, ELECTRICAL |
CXDM | Conductor Cross-Sectional Shape | TUBULAR SOLID 3RD CONDUCTOR |
CXCW | Conductor Form | SOLID, TUBULAR 2ND CONDUCTOR |
CXCW | Conductor Form | SOLID, TUBULAR 3RD CONDUCTOR |
CXCW | Conductor Form | SOLID 1ST CONDUCTOR |
CXDQ | Conductor Arrangement And Quantity | 1 COAXIAL |
CRTL | Criticality Code Justification | AGAV |
AAGR | Cross-Sectional Shape Style | ROUND |
AMQN | Conductor Quantity | 3 |
MATT | Material | COPPER 2ND POSITION SECONDARY INSULATION THIRD CONDUCTOR |
MATT | Material | PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
MATT | Material | STEEL CORE CONDUCTOR FIRST CONDUCTOR |
ABKV | Outside Diameter | 0.0141 INCHES NOMINAL 3RD CONDUCTOR |
AARX | Inside Diameter | 0.005 INCHES NOMINAL 1ST CONDUCTOR |
PMLC | Precious Material And Location | PLATING ON COPPER COATING OF FIRST CONDUCTOR SILVER |
AAJU | Overall Length | 15.250 INCHES |
CXCY | Part Name Assigned By Controlling Agency | CABLE ASSY, SEMI-RIGID SMA (M) / SMA (M) |
FEAT | Special Features | SCABLE IS M17/130-00005; HAS 4 IDENTIFICATION MARKERS: ONE MARKED :TO" ABOVE "J2", ONE "W2" ABOVE "20419ASSY734227-3", ONE "TO" ABOVE "A2-J2", AND ONE WITH MFR'S REF. NO; ASSY HAS 2 ROUNDED 90 DEG BENDS AND ONE RIGHT ANGLE BEND |
STYL | Style Designator | EXTERNAL CONNECTORS |
SFTT | Surface Treatment | COPPER CORE COATING FIRST CONDUCTOR AND SILVER CORE COATING FIRST CONDUCTOR |
SFTT | Surface Treatment | TIN 2ND POSITION COATING THIRD CONDUCTOR |
ABJH | Temp Rating | -40.0 DEG CELSIUS AND 125.0 DEG CELSIUS |
CXGN | Terminal Commercial And Government Entity Code | 00779 ALL ENDS ALL CONDUCTORS |
CXGG | Terminal Manufacturer Identifying Reference Number | 228635-1 ALL ENDS ALL CONDUCTORS |
AKRZ | Termination Type | CONNECTOR PLUG ALL ENDS ALL CONDUCTORS |