5995-01-493-1872

CABLE ASSEMBLY,POWER,ELECTRICAL


5995-01-493-1872 (5995014931872, 014931872)
Part Numbers (2 listings): 90-977-218 | 1215461-218 |
Summary

FSG 59 / FSC 5995

DEMIL: A

DEMIL INT: 1

HMIC: N

Date Created: 19 Dec 2001

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5995-01-493-1872 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
90-977-2183 - Design Control Reference2 - Production ItemTELEDYNE REYNOLDS, INC.  57500      
1215461-2185 - Replaced / Discontinued2 - Production ItemLOCKHEED MARTIN CORPORATION  03538    CAGE 03538  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5995-01-493-1872 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595995014931872A077A000485X1ANAS019 Dec 2001
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5995

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Cable, Cord, and Wire Assemblies: Communication Equipment

014931872

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5995-01-493-1872

A077A0

Federal Item Identification Guide (FIIG_4065)

00485

Item Naming Code (INC_4080)

19 Dec 2001

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

1

Type of Item Identification (TYP_II_4820)


Full Descriptive Item Identification

A

Demilitarization Code (DEMIL_CD_0167)


Non-MLI/ Non-SLI — Demilitarization not required.

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

S

Precious Metals Indicator Code (PMIC_0802)


Item contains silver.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5995-01-493-1872 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZR011 Dec 2001
YB011 Feb 2003
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5995-01-493-1872 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZD90-977-218  57500  
45249ZD1215461-218  03538   CAGE/03538
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5995-01-493-1872 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597019 Dec 2001
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

19 Dec 2001

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5995-01-493-1872 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
AM
Code Definitions

AM

Originating Activity Code (ORIG_ACTY_CD_4210)


U.S. Army Medical Materiel Agency, Frederick, MD 21701-5001

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5995-01-493-1872 Submit RFQ
MRCDecoded RequirementClear Text Reply
CXDMConductor Cross-Sectional ShapeTUBULAR BRAID SINGLE CONDUCTOR
CXCWConductor FormBRAID, TUBULAR SINGLE CONDUCTOR
AAGRCross-Sectional Shape StyleROUND
AGAVEnd Item IdentificationSTEP DOWN TRANSFORMER
ADZCEnvironmental ProtectionCHEMICAL RESISTANT AND MOISTURE RESISTANT AND SALT AIR RESISTANT
AMQNConductor Quantity1
MATTMaterialCOPPER ALLOY CORE CONDUCTOR SINGLE CONDUCTOR
MATTMaterialSILVER 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
ABKVOutside Diameter0.210 INCHES NOMINAL SINGLE CONDUCTOR
MDCLMaterial Document And ClassificationASTM-B-298 ASSN STD SINGLE MATERIAL RESPONSE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR
PMLCPrecious Material And LocationCONDUCTOR INSULATION SILVER
PRMTPrecious MaterialSILVER
AAJUOverall Length218.000 INCHES
CXCYPart Name Assigned By Controlling AgencyFLEXIBLE CABLES, (90 SERIES)
FEATSpecial FeaturesSECOND END IS AN EXTENDED RIGHT ANGLE PLUG; FREQUENCY RANGE - 26GHZ; HIGHEST POWER RATING- 26 GHZ; 150 LBS/INCOMPRESSION STRENGTH; 40 LB CONNECTOR RETENTION; MINIMUM BEND RADIUS - 1.00 IN.
CXFKVoltage Rating6000.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR
STYLStyle DesignatorSTRAIGHT
ABJHTemp Rating-55.0 DEG CELSIUS AND 150.0 DEG CELSIUS
AKRZTermination TypeCONNECTOR INTERNAL ANGLE BOTH ENDS SINGLE CONDUCTOR


Back to Top
Back to Top