| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| BS-2000-010-314 | 3 - Design Control Reference | 2 - Production Item | BARON SERVICES, INC. | 1KR45 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5995 | 016149339 | A077A0 | 00782 | X | 1 | B | N | A | A | 0 | 19 Dec 2012 |
Cable, Cord, and Wire Assemblies: Communication Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| B471 | 0 | 0 | 1 Dec 2012 | |||||||||||||||||||||||||||
| R47A | 0 | 0 | 1 Dec 2012 | |||||||||||||||||||||||||||
Not Established
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 2 | 1 | ZZ | BS-2000-010-314 | 1KR45 | | ||||||
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
USA
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 5 | 97 | 0 | 19 Dec 2012 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 47 |
National Weather Service, Silver Spring, MD 20910
No Variation. NMFC and UFCC Match.
Department of Commerce, National Oceanic and Atmospheric Administration, National Weather Service - Engineering Division, 1325 East-West Highway, W/0S0322, SSMC2, Silver Springs, MD 20910
GENERAL SERVICES ADMINISTRATION (GSA)/CIVIL AGENCY INTEGRATED MATERIEL MANAGED, STOCKED AND ISSUED Identifies GSA/Civil Agency-managed items available from GSA/Civil Agency supply distribution facilities. Requisitions and fund citations will be submitted in accordance with GSA/Civil Agency/Service requisitioning procedures.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
National Weather Service
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AMQN | Conductor Quantity | 8 |
| CXCW | Conductor Form | STRANDED ALL CONDUCTORS |
| MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
| MATT | Material | PLASTIC ETHYLENE-TETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
| MATT | Material | RUBBER 2ND POSITION JACKET CABLE |
| SFTT | Surface Treatment | TIN CORE CONDUCTOR ALL CONDUCTORS |
| CXDC | Round Conductor Size | 18 AWG 1ST CONDUCTOR |
| CXDC | Round Conductor Size | 18 AWG 2ND CONDUCTOR |
| CXDC | Round Conductor Size | 18 AWG 3RD CONDUCTOR |
| CXDC | Round Conductor Size | 18 AWG 4TH CONDUCTOR |
| CXDC | Round Conductor Size | 22 AWG 5TH CONDUCTOR |
| CXDC | Round Conductor Size | 22 AWG 6TH CONDUCTOR |
| CXDC | Round Conductor Size | 22 AWG 7TH CONDUCTOR |
| CXDC | Round Conductor Size | 22 AWG 8TH CONDUCTOR |
| BLNZ | Strand Quantity Per Conductor | 19 ALL CONDUCTORS |
| CXDG | Strand Awg Size Per Conductor | 30 1ST CONDUCTOR |
| CXDG | Strand Awg Size Per Conductor | 30 2ND CONDUCTOR |
| CXDG | Strand Awg Size Per Conductor | 30 3RD CONDUCTOR |
| CXDG | Strand Awg Size Per Conductor | 30 4TH CONDUCTOR |
| CXDG | Strand Awg Size Per Conductor | 34 5TH CONDUCTOR |
| CXDG | Strand Awg Size Per Conductor | 34 6TH CONDUCTOR |
| CXDG | Strand Awg Size Per Conductor | 34 7TH CONDUCTOR |
| CXDG | Strand Awg Size Per Conductor | 34 8TH CONDUCTOR |
| AAJU | Overall Length | 12.000 INCHES |
| AAGR | Cross-Sectional Shape Style | ROUND |
| AKRZ | Termination Type | CONNECTOR PLUG BOTH ENDS ALL CONDUCTORS |
| CXGG | Terminal Manufacturer Identifying Reference Number | 171-037-103L001 BOTH ENDS ALL CONDUCTORS |
| CXGN | Terminal Commercial And Government Entity Code | 1L3S8 BOTH ENDS ALL CONDUCTORS |
| AGAV | End Item Identification | RDA NEXRAD |
| CXCY | Part Name Assigned By Controlling Agency | CABLE ASSY, DB37 M TO DB37 M, 4W578 |