5996-00-305-6147

AMPLIFIER,RADIO FREQUENCY


5996-00-305-6147 (5996003056147, 003056147)
Part Numbers (2 listings): PA2586-506REVB | SMC91180-G6 |
Summary

FSG 59 / FSC 5996

DEMIL: C

DEMIL INT:

HMIC: N

Date Created: 1 Jan 1963

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5996-00-305-6147 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
PA2586-506REVB3 - Design Control Reference9 - No Longer UsedUTILITY ELECTRONIC CORP  82892      
SMC91180-G6C - Advisory Reference1 - Incomplete Part NumberUS ARMY COMMUNICATIONS &  80063    CAGE 80063  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

C - Advisory Reference

Reference Number Category Code (DRN_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

1 - Incomplete Part Number

Reference Number Variation Code (DRN_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.


FLIS - SEG A - IDENTIFICATION | NSN 5996-00-305-6147 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595996003056147A3220000446XM9CNA01 Jan 1963
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5996

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Amplifiers

003056147

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5996-00-305-6147

A32200

Federal Item Identification Guide (FIIG_4065)

00446

Item Naming Code (INC_4080)

1 Jan 1963

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

M

Type of Item Identification (TYP_II_4820)


Partial Descriptive - Reference Item Identification (Type 1A Concept)

9

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).

C

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Remove and/or demilitarize installed key point(s) as prescribed in DOD 4160.21-M-1 — Defense Demilitarization Manual, or lethal parts, components and accessories

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5996-00-305-6147 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZU011 Apr 1991
YB011 Feb 1994
ZW011 Nov 1998
N9BNN9ND5HZHDHD1 Apr 2006
YY011 Feb 2015
Code Definitions

5

Acquisition Method Code (AMC_2871)


Acquire only from the prime contractor although the engineering data identifies the Commercial and Government Entity Code (CAGE) and part number of a source other than the prime contractor. The DoD activity assigning this code shall furnish the name and CAGE Code of the prime contractor to the activity responsible for acquiring the part.

H

Acquisition Method Suffix Code (AMSC_2876)


The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

HD

Item Management Coding Activity (IMC_ACTY_2748)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788

HDCollaborators

Supplementary Collaborators (SUPPLM_COLLBR_2533)


Naval Inventory Control Point, Mechanicsburg, PA 17055-0788


FLIS - SEG C - REFERENCE NUMBER | NSN 5996-00-305-6147 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
C16ZZACSMC91180-G6  80063   CAGE/80063
Code Definitions

C

Reference Number Category Code (RNCC_2910)


Advisory Reference. A number assigned to an item of production or supply not included in the item-of-supply concept to which the NSN has been assigned (e.g., an item that may have been used in the preproduction equipment design which has since been redesigned or replaced). Use of this RNCC is restricted to conditions where cross-reference is required to establish identification to an item of supply. Additionally, there is not direct relationship of the reference number to the NSN other than a Service/Agency individual decision. (RNCC shall be used only in conjunction with RNVC 1.

1

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.

6

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing but the documentation was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

AC

Service / Agency Designator Code (SADC_4672)


Navy


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5996-00-305-6147 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
697015 Aug 1983
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

15 Aug 1983

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5996-00-305-6147 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
723Z9AHZG063035X35070
Code Definitions

XX

Originating Activity Code (ORIG_ACTY_CD_4210)


723

Water Commodity Code (WRT_CMDTY_CD_9275)


Radio Parts, Batteries and Equipment, excluding Tubes Packed separately

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

G

Less Than Truckload (CLAS_RTNG_CD_2770)


125

063035

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35070

Uniform Freight Classification (UFC_CD_MODF_3040)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5996-00-305-6147 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DNSMSX71EA0
DSSMSX71EA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

X

Acquisition Advice Code (AAC_2507)


SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.

7

Controlled Item Inventory Code (CIIC_2863)


Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).

1

Quantity Unit Pack (QUP_6106)


1

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

DN

Service / Agency Code (MOE_CD_2833)


Department of the Navy

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5996-00-305-6147 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFSUAverage Life MeasurementNOT RATED
AGTABasic Shape StyleRECTANGULAR OR SQUARE
BKFBExternal Dc Operating Voltage In Volts1.4 NOMINAL 1ST VOLTAGE
BKFBExternal Dc Operating Voltage In Volts65.0 NOMINAL 2ND VOLTAGE
CBBLFeatures ProvidedINTERNAL BATTERY ACCOMMODATION
BHTBFrequency Per Channel55.0 MEGAHERTZ MAXIMUM OPERATING CHANNEL
BHTBFrequency Per Channel38.0 MEGAHERTZ MINIMUM OPERATING CHANNEL
BHSXCircuit Construction TypeSOLID STATE
AKNAInclosure TypeENCASED
ABKWOverall Height1.983 INCHES NOMINAL
ABHPOverall Length2.531 INCHES NOMINAL
ABMKOverall Width0.531 INCHES NOMINAL


Back to Top