Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
MS | 3 - Design Control Reference | 2 - Production Item | NORTHROP GRUMMAN SYSTEMS CORPORATION | 97942 | ![]() |
MS | 5 - Replaced / Discontinued | 2 - Production Item | WESTINGHOUSE ELECTRIC CORP | 79500 | ![]() |
AM1805FRC | 5 - Replaced / Discontinued | 2 - Production Item | JOINT ELECTRONICS TYPE DESIGNATION | 80058 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5996 | 005812246 | A32200 | 00446 | X | M | 9 | C | N | U | 1 Jan 1963 |
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
A Defense Logistics Information Service-generated code for items lacking but requiring an RPDMRC (i.e., through mass FIIG revision change an item may be downgraded from a type 1 to a reference or partial descriptive method item identification).
MLI (SME) — Remove and/or demilitarize installed key point(s) as prescribed in DOD 4160.21-M-1 — Defense Demilitarization Manual, or lethal parts, components and accessories
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZU | ||||||||||||||||||||||||||||||
ZU01 | 1 Apr 1991 |
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No Variation. NMFC and UFCC Match.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
BHTJ | Average Power Rating Per Channel | 2.5 KILOWATTS INPUT |
BHTJ | Average Power Rating Per Channel | 30.0 MILLIWATTS OUTPUT |
AGTA | Basic Shape Style | RECTANGULAR OR SQUARE |
AQZF | Control Type | LOCAL |
BKFC | External Ac Operating Voltage In Volts | 208.0 NOMINAL 1ST VOLTAGE |
BKFC | External Ac Operating Voltage In Volts | 230.0 NOMINAL 2ND VOLTAGE |
BKFC | External Ac Operating Voltage In Volts | 250.0 NOMINAL 3RD VOLTAGE |
BHTB | Frequency Per Channel | 26.500 MEGAHERTZ MAXIMUM OPERATING CHANNEL ERR-100 |
BHTB | Frequency Per Channel | 4.000 MEGAHERTZ MINIMUM OPERATING CHANNEL ERR-100 |
ZZZV | Fsc Application Data | RADIO TRANSMITTER SET,EXCEPT NAVIGATION,NONAIRBORNE |
AJKH | Identification Designator | AM1805FRC-80058 |
BHSX | Circuit Construction Type | ELECTRON TUBE |
BJBQ | Operating Ac Frequency In Hertz | 50.0 MINIMUM SINGLE VOLTAGE |
BJBQ | Operating Ac Frequency In Hertz | 60.0 MAXIMUM SINGLE VOLTAGE |
ALBM | Operating Control Method | MANUAL |
BHTN | Impedance Rating Per Channel | 0.070 KILOHMS INPUT CHANNEL ERR-100 |
BHTN | Impedance Rating Per Channel | 0.900 KILOHMS OUTPUT CHANNEL ERR-100 |
AKNA | Inclosure Type | ENCASED |
BJBL | Indicator Device Type And Quantity | 24 LIGHT AND 13 METER |
AMQY | Installation Design | FREE-STANDING |
ABKW | Overall Height | 87.500 INCHES NOMINAL |
ABHP | Overall Length | 96.000 INCHES NOMINAL |
ABMK | Overall Width | 46.000 INCHES NOMINAL |
FAAZ | Phase | THREE |
FEAT | Special Features | DC POWER SUPPLY INC; TEN (10) PRESET CHANNELS AND MANUAL TUNING; FOUR (4) CHANNELS SIMULTANEOUS TRANSMISSION |