5996-01-197-7005

AMPLIFIER,INTERMEDIATE FREQUENCY


5996-01-197-7005 (5996011977005, 011977005)
Part Numbers (4 listings): 600963-01 | SDA6020/04863 | ICL-4-3012 | 600963 |
Summary

FSG 59 / FSC 5996

DEMIL: C

DEMIL INT: 1

HMIC: N

Date Created: 24 Dec 1984

Unit Weight: 0.5 lbs

Unit Size: 5in x 2in x 3in

Unit Pack Cube: 0.017 cu ft

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5996-01-197-7005 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
600963-013 - Design Control Reference2 - Production ItemDB ENGINEERING  4FVC6      
SDA6020/048635 - Replaced / Discontinued2 - Production ItemPASCALL ELECTRONICS INC  0CNF1      
600963-015 - Replaced / Discontinued9 - No Longer UsedPASCALL ELECTRONICS INC  0CNF1      
ICL-4-30125 - Replaced / Discontinued9 - No Longer UsedCOMMUNICATIONS & POWER INDUSTRIES  88236      
SDA6020/048635 - Replaced / Discontinued9 - No Longer UsedBONNER AND BONNER INC  07KC9      
ICL-4-30125 - Replaced / Discontinued9 - No Longer UsedCRANE ELECTRONICS, INC.  0N8W8      
600963-015 - Replaced / Discontinued9 - No Longer UsedEDO  09017    CAGE 09017  
600963-017 - Vendor Item Drawing Reference2 - Production ItemEDO COMMUNICATIONS AND  1C2N9      
600963D - Drawing Number Reference9 - No Longer UsedEDO  09017    CAGE 09017  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

7 - Vendor Item Drawing Reference

Reference Number Category Code (DRN_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

D - Drawing Number Reference

Reference Number Category Code (DRN_2910)


Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5996-01-197-7005 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595996011977005A3220000885XKCNA024 Dec 1984
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5996

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Amplifiers

011977005

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5996-01-197-7005

A32200

Federal Item Identification Guide (FIIG_4065)

00885

Item Naming Code (INC_4080)

24 Dec 1984

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

C

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Remove and/or demilitarize installed key point(s) as prescribed in DOD 4160.21-M-1 — Defense Demilitarization Manual, or lethal parts, components and accessories

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5996-01-197-7005 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
A918A1961RZCDCT1 Apr 2006
FUGX1RZSU1 Apr 2006
Code Definitions

1

Acquisition Method Code (AMC_2871)


Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.

R

Acquisition Method Suffix Code (AMSC_2876)


The data or the rights to use the data needed to purchase this part from additional sources are not owned by the Government and it has been determined that it is uneconomical to purchase them. Valid AMCs: 1, 2, 3, 4 and 5.

Z

Item Management Code (IMC_2744)


Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.

CD

Item Management Coding Activity (IMC_ACTY_2748)


U.S. Army War Reserve Command, New Cumberland, PA 17070-5008

SU

Item Management Coding Activity (IMC_ACTY_2748)


Ogden Air Logistics Center, Hill AFB, UT 84056-5609

CT

Supplementary Receivers (SUPPLM_RCVR_2534)


U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230


FLIS - SEG C - REFERENCE NUMBER | NSN 5996-01-197-7005 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
525ZZBSDA6020/04863  0CNF1  
595ZZBICL-4-3012  0N8W8  
592SBICL-4-3012  88236  
595ZZBSDA6020/04863  07KC9  
592SBB600963-01  09017   CAGE/09017
595ZZB600963-01  0CNF1  
725ZZ600963-01  1C2N9  
D92SB600963  09017   CAGE/09017
Code Definitions

5

Reference Number Category Code (RNCC_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

5

Document Availability Code (DAC_2640)


The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA

B

Reference Number Status Code (RNSC_2923)


Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.

9

Reference Number Variation Code (RNVC_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.

2

Document Availability Code (DAC_2640)


The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the drawing.

SB

Reference Number Action Activity Code (RNAAC_2900)


645 MSSQ/MSIAPCS, Wright-Patterson AFB, OH 45433-5603

7

Reference Number Category Code (RNCC_2910)


Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.

D

Reference Number Category Code (RNCC_2910)


Drawing Number Reference. A number assigned by a design activity to a drawing or other technical documentation which identifies a drawing/document that is related to an item of supply or production but does not qualify for assignment of codes 1,3,5,7, or C. Code D reference numbers will not be used in item-of-supply determinations.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5996-01-197-7005 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
6TU024 Dec 1984
Code Definitions

6

Item Standardization Code (ISC_2650)


An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.

TU

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


AF Cataloging Agent DLIS-K, Battle Creek, MI 49037-3094

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

24 Dec 1984

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5996-01-197-7005 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
TA658Z9AHZG063035X35070
Code Definitions

TA

Originating Activity Code (ORIG_ACTY_CD_4210)


Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609

658

Water Commodity Code (WRT_CMDTY_CD_9275)


Electical Appliances, Small

Z

Type Cargo Code (TYPE_CGO_CD_9260)


No special type of cargo code applicable

9

Special Handling Code (SP_HDLG_CD_9240)


No special handling required

A

Air Dimension Code (AIR_DIM_CD_9220)


Shipment is not a consolidation and does not exceed 72 inches in any dimension.

H

Air Commodity Code (AIR_CMTY_HDLG_9215)


Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.

Z

Air Special Handling Code (AIR_CMTY_HDLG_9215)


No special handling required.

G

Less Than Truckload (CLAS_RTNG_CD_2770)


125

063035

National Motor Freight Classification Number (NMFC Item Number) (NMFC_2850)

X

NMFC Sub Item Number (SUB_ITM_NBR_0861)

35070

Uniform Freight Classification (UFC_CD_MODF_3040)

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG H - MANAGEMENT DATA | NSN 5996-01-197-7005 Submit RFQ
Unit PriceMOESOSAACCIICQUPReparabilityUISLC
DASMSZ71ZEA0
DFSMSZ71PEA0
DSSMSZ71FEA0
Code Definitions

SMS

Source of Supply (SOS_CD_3690) or Source of Supply Modifier (SOSM_CD_2948)


Defense Logistics Agency, Enterprise Business Systems

Z

Acquisition Advice Code (AAC_2507)


INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM. Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.

7

Controlled Item Inventory Code (CIIC_2863)


Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).

1

Quantity Unit Pack (QUP_6106)


1

Z

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item; MARINE CORPS: Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code; NAVY: Special Program Consumables

EA

Unit of Issue (UI_3050)


Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.

0

Shelf Life Code (SLC_2943)


TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.

P

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


AIR FORCE ERRC XF3: Stock Fund (Except Munitions); NAVY: Perishable Subsistence Items

F

Reparability Code (REP_CD_DLA_2934 / REP_CD_CG_0709 / ERRC_CD_AF_2655 / RECOV_CD_MC_2891 / RECOV_CD_AR_2892 / MAT_CTL_NVY_2832)


ARMY: If condemned or uneconomically repairable, then dispose at direct support (ds) level; DLA: This item has been reviewed and a determination made that the item can be restored to a serviceable condition from an unserviceable condition at the organizational/field level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at the third echelon level; NAVY: (1) Fast-Moving 1I Cog Forms (2) Non-Perishable Provisions

DA

Service / Agency Code (MOE_CD_2833)


Department of the Army

DF

Service / Agency Code (MOE_CD_2833)


Department of the Air Force

DS

Service / Agency Code (MOE_CD_2833)


Defense Logistics Agency


FLIS - SEG W - PACKAGING DATA | NSN 5996-01-197-7005 Submit RFQ
SourcePICA / SICAPackaging CategoryStoragePreservationClean/DryINT QtyUnit WeightUnit SizeUnit Pack CubeItem WeightItem Dims
PP411AAA0.5 lbs5in x 2in x 3in0.017 cu ft
Preservation MaterialWrapping MaterialCushioning / DunnageCushioning ThicknessUnit ContainerIntermediate ContainerUnit Container LevelSpecial MarkingLevel A PackingLevel B PackingMinimal PackingOptional Procedure
00NAXE6E500QQO
Code Definitions

P

Packaging Data Source Code (PK_DTA_SRC_CD_5148)


Primary Inventory Control Activity (PICA)

P

Primary / Secondary Inventory Control Code (PICA_SICA_IND_5099)


Primary Inventory Control Activity (PICA)

41

Method of Preservation Code (MTHD_PRSRV_CD_5160)


Watervaporproof bag, sealed

1

Cleaning and Drying Procedure Code (CLNG_DRY_PRC_5161)


Any suitable process that is not injurious to the item.

AAA

Intermediate Container Quantity (INTMD_CTN_QTY_5152)

0.5 lbs

Unit Pack Weight (UP_WT_5153)

5in x 2in x 3in

Unit Pack Size (UP_SZ_5154)

0.017 cu ft

Unit Pack Cube (UP_CU_5155)

00

Preservation Material Code (PRSRV_MAT_CD_5162)


No requirement

NA

Cushioning and Dunnage Material Code (CUSH_DUN_MAT_5164)


PPP-C-795, cellular plastic film cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene foam cushioning; or A-A-59136, polyethylene foam cushioning

X

Thickness of Cushioning or Dunnage Code (THK_CUSH_DUN_5165)


As required to protect the item or elements of the package

E6

Unit Container Code (UNIT_CTNR_CD_5166)


Vendor's fiberboard box.

E5

Intermediate Container Code (INTMD_CTNR_CD_5167)


ASTM-D5118, fiberboard box.

00

Special Marking Code (SP_MKG_CD_5169)


No special marking

Q

Packing Requirement Code - For Level A (Maximum) Packing (LVL_A_PKG_CD_5170)


Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Q

Packing Requirement Code - For Level B (Intermediate) Packing (LVL_B_PKG_CD_5171)


Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

O

Optional Procedure Indicator Code (OPTNL_PRO_IND_5173)


Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5996-01-197-7005 Submit RFQ
MRCDecoded RequirementClear Text Reply
AFSUAverage Life MeasurementNOT RATED
AGTABasic Shape StyleRECTANGULAR OR SQUARE
BJBWConnection Contact Type And Quantity2 RECEPTACLE, COAXIAL EXTERNAL
BJBPConnection Type And LocationRECEPTACLE, COAXIAL RIGHT SIDE
BKFBExternal Dc Operating Voltage In Volts15.0 NOMINAL SINGLE VOLTAGE
BHTBFrequency Per Channel60.0 MEGAHERTZ NOMINAL OPERATING CHANNEL
BHSXCircuit Construction TypeSOLID STATE
AGAVEnd Item Identification5840-01-137-5984,RADAR SIGNAL SIMULATOR,AN/MSQ-T43(V)3
AFGAOperating Temp Range-30.0 TO 70.0 DEG CELSIUS
FTLDFunctional DescriptionAMPLIFIER,LOGARITHMIC,INTERMEDIATE FREQUENCY
AFJQStorage Temp Range-51.0 TO 55.0 DEG CELSIUS
SUPPSupplementary FeaturesDYNAMIC RANGE,INPUT: -80 TO 0 DBM
BHTNImpedance Rating Per Channel50.000 OHMS INPUT CHANNEL
BHTNImpedance Rating Per Channel93.000 OHMS OUTPUT CHANNEL
AKNAInclosure TypeENCASED
CMGXIntermediate Frequency Bandpass5.0 MEGAHERTZ
AMQYInstallation DesignMODULE
ABKWOverall Height0.500 INCHES NOMINAL
ABHPOverall Length3.750 INCHES NOMINAL
ABMKOverall Width1.500 INCHES NOMINAL


Back to Top