Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
G287706-1 | 3 - Design Control Reference | 2 - Production Item | RAYTHEON TECHNICAL SERVICES COMPANY | 3B150 | ![]() |
AM-7361/U | 5 - Replaced / Discontinued | 2 - Production Item | JOINT ELECTRONICS TYPE DESIGNATION | 80058 | ![]() |
G287706-1 | 5 - Replaced / Discontinued | 9 - No Longer Used | RAYTHEON COMPANY | 49956 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5996 | 013258555 | A32200 | 00446 | Y | K | D | N | A | A | 0 | 12 Sep 1990 |
The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A588 | A542 | 0 | 0 | 5 | E | FH | 1 Nov 1999 | |||||||||||||||||||||||
FUU4 | FAA4 | 0 | 0 | F | E | FH | 1 Nov 1999 | |||||||||||||||||||||||
NSUS | 0 | 0 | 5 | E | FH | KF | GG | 1 Jun 2000 |
Not Established
Depot Reparable Component (Type II). This code identifies SICA managed depot reparable components assigned to another service which is responsible for the logistics functions of single submitter cataloger, acquisition and disposal authority, depot maintenance, and performs the wholesale stock, store, and issue functions and establishes, budgets, and funds the wholesale stock level requirement. Supply requirements will be submitted to the PICA on requisitions which are funded by a designated point within the SICA. Unserviceable SICA assets will normally be returned to the PICA for credit. The SICA will provide item/program data required by the PICA to meet the materiel support commitments. Normally, Military Interdepartmental Purchase Requests (MIPR) will not be requested by the PICA to support SICA NIMSC 5 requirements. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
An activity within the Air Force is providing depot maintenance support.
Ogden Air Logistics Center (OO-ALC), Hill AFB, UT
Navy Material Transportation Office, Naval Station Norfolk, VA 23511
Naval Inventory Control Point, Philadelphia, PA 19111û5098
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
6 | TX | 0 | 15 Sep 1990 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TA | 72D | Z | 9 | A | H | Z | J | 061700 | X | 34580 | ELEC-APPLIANCES-INSTRUMENTS-NOI |
Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609
Communications/Electronics, other than SIGINT/EW or COMSEC. Repair Parts and Components
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
100.2
No Variation. NMFC and UFCC Match.
US Army Communications-Electronics, Command and Fort Monmout, Fort Monmouth, NJ 07703-5016
TERMINAL ITEM. Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).
1
ARMY: When repair is beyond lower level maintenance capability, evacuate the item to depot. Disposal is not authorized below wholesale level; MARINE CORPS: Reparable item. When beyond lower level repair capability, return to depot. Condemnation and disposal not authorized below depot level; NAVY: Field Level Reparables
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE II (18 Months (1.50-Years) ) - An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Ogden Air Logistics Center, 5851 F Ave, Hill AFB, UT 84056-5713
AIR FORCE ERRC XD2: AF Recoverable Assembly Management System (AFRAMS); NAVY: Terminal Items
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
Department of the Army
Department of the Air Force
Department of the Navy
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | GX | 1 | 000 | 170.0 lbs | 39.3in x 25.5in x 21in | 12.178 cu ft | 80.0 lbs | 29in x 15in x 8in |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | ZZ | ZZ | Z | ZZ | 00 | B | ZZ | A |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Preserve by Method 41 as follows: Items subject to damage by electromagnetic and electrostatic field forces shall be initially wrapped in material conforming to MIL-PRF-81705, Type III, or bags conforming to MIL-DTL-117, Type II, Class H, Style 2, or cushioned in material conforming to A-A-3129, Type I, Grade B or PPP-C-795, Class 2 or PPP-C-1797, Type II, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to MIL-DTL-117, Type I, Class F, Style 1. Reclosable cushioned pouches conforming to MIL-DTL-81997, Type I or II, may be used in lieu of initial wrap or cushioning. Lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. Materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. Electrostatic discharge (ESD) sensitive caution labels shall be applied in accordance with MIL-STD-129.
Any suitable process that is not injurious to the item.
No requirement
Special requirements – see specific instructions or drawings provided
Special requirements. See specific instructions or drawings provided.
Special requirements-See specific instructions or drawings provided
Special requirement – See specific instructions or drawings provided.
No requirement.
Unit container provides level B packing protection.
Special requirements
Packaging is in accordance with a procedural specification or a SPI. The appropriate specification number will be shown in-the-clear in the supplemental data area.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AGAV | End Item Identification | MILSTAR |
AFSU | Average Life Measurement | NOT RATED |
AGTA | Basic Shape Style | RECTANGULAR OR SQUARE |
CRTL | Criticality Code Justification | FEAT |
BHSX | Circuit Construction Type | SOLID STATE |
AKNA | Inclosure Type | ENCASED |
AMQY | Installation Design | MECHANICAL |
ABKW | Overall Height | 7.600 INCHES NOMINAL |
ABHP | Overall Length | 24.880 INCHES NOMINAL |
ABMK | Overall Width | 14.380 INCHES NOMINAL |
FEAT | Special Features | HARDNESS CRITICAL ITEM |
SUPP | Supplementary Features | SHF INPUT SIGNAL OF 6.4 TO 7.424 GHZ FREQ. RANGE; L-BAND INPUT SIGNAL OF 1325 OR 1361.57 MHZ FREQ.; EHF OUTPUT SIGNAL OF 43.5 TO 45.5 GHZ FREQ. RANGE; POWER SUPPLIED BY THE HIGH VOLTAGE POWER SUPPLY P/N G291227-1; CAN BE CEILING OR FLOOR MOUNTED; PERFORMS TWO BASIC FUNCTIONS 1-FREQUENCY UPCONVERSION TO A SPECIFIED EHF OUTPUT RANGE 2-RF POWER AMPLIFICATION TO A SPECIFIED OUTPUT LEVEL; DESIGNED FOR AIRBORNE AND GROUND USE |