5996-01-361-4972

AMPLIFIER,RADIO FREQUENCY


5996-01-361-4972 (5996013614972, 013614972)
Part Number (1 listing): 8010H02F000
Summary

FSG 59 / FSC 5996

DEMIL: D

DEMIL INT: 1

HMIC: N

Date Created: 17 Jul 1992

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5996-01-361-4972 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
8010H02F0003 - Design Control Reference2 - Production ItemDYNAMIC WAVE TELECOM INC.  1L7Y9      
8010H02F0005 - Replaced / Discontinued9 - No Longer UsedL-3 COMMUNICATIONS ELECTRON  73293    CAGE 73293  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

5 - Replaced / Discontinued

Reference Number Category Code (DRN_2910)


Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

9 - No Longer Used

Reference Number Variation Code (DRN_4780)


A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.


FLIS - SEG A - IDENTIFICATION | NSN 5996-01-361-4972 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595996013614972A3220000446XKDNAA017 Jul 1992
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5996

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Amplifiers

013614972

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5996-01-361-4972

A32200

Federal Item Identification Guide (FIIG_4065)

00446

Item Naming Code (INC_4080)

17 Jul 1992

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

K

Type of Item Identification (TYP_II_4820)


Full Descriptive - Reference Item Identification

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5996-01-361-4972 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZW011 Dec 2005
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5996-01-361-4972 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
324ZZ8010H02F000  1L7Y9  
Code Definitions

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

ZZ

Reference Number Action Activity Code (RNAAC_2900)


USA


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5996-01-361-4972 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597017 Jul 1992
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

17 Jul 1992

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5996-01-361-4972 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
SE
Code Definitions

SE

Originating Activity Code (ORIG_ACTY_CD_4210)


San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5996-01-361-4972 Submit RFQ
MRCDecoded RequirementClear Text Reply
BHTJAverage Power Rating Per Channel10.0 WATTS OUTPUT
AFSUAverage Life MeasurementNOT RATED
AGTABasic Shape StyleRECTANGULAR OR SQUARE
BJBPConnection Type And LocationRECEPTACLE, COAXIAL FRONT
BJBWConnection Contact Type And Quantity1 RECEPTACLE, COAXIAL INTERNAL
AQZFControl TypeLOCAL
BKFCExternal Ac Operating Voltage In Volts99.0 MINIMUM SINGLE VOLTAGE AND 132.0 MAXIMUM SINGLE VOLTAGE
BHTBFrequency Per Channel
BHSXCircuit Construction TypeSOLID STATE
AFJKCubic Measure0.733 CUBIC FEET
AKAEMaximum Operating Altitude Rating10000.0 FEET
ALBMOperating Control MethodMANUAL
BJBQOperating Ac Frequency In Hertz47.0 MINIMUM SINGLE VOLTAGE AND 63.0 MAXIMUM SINGLE VOLTAGE
AFGAOperating Temp Range+0.0 TO 50.0 DEG CELSIUS
ABBHInclosure MaterialALUMINUM
BJBRMaximum Power Drain Rating250.0 WATTS
RTSERelationship To Similar Equipment6625-01-034-6118
AKNAInclosure TypeENCASED
AMQYInstallation DesignTOP OF CABINET/COUNTER AND RACK
BHTLOverall Gain30.0 DECIBELS
ABKWOverall Height3.500 INCHES NOMINAL
ABHPOverall Length21.240 INCHES NOMINAL
ABMKOverall Width18.240 INCHES NOMINAL
FAAZPhaseSINGLE
FEATSpecial FeaturesFRONT PANEL CONTROLS: PRIME POWER ON/OFF,RF OPERATE/STANDBY (FAULT RESET). FRONT PANEL INDICATORS: PRIME POWER ON/STANDBY,RF OPERATE,FAULT. METERING: HELIX CURRENT. PROTECTION: PRIME POWER FUSE,WARM UP DELAY,AUTOMATIC SEQUENCING OF HIGH VOLTAGE AND BEAM CURRENT,UNATTENDED PROTECTION (HEATER SHUTDOWN AFTER FAULT COUNTER TRIP),HELIX CURRENT OVERLOAD,HIGH TEMPERATURE LOW/HIGH LINE VOLTAGE,SAFETY INTERLOCKS. EQUIPMENT CASE,IS A SELF-CONTAINED DESIGNED FOR BENCH TOP OR RACK MOUNT. AUTO RECYCLE IF POWER OUTAGE IS LESSTHAN 3 SECONDS. AUTOMATIC TURN OFF IF TWO CONSECUTIVE HELIX OVERLOAD FAULTS OCCUR:NOISE FIGURE 35DB MAX: SPURIOUS MODULATION M50DBC MAX: LOAD VSWR 2.5:1 MAX: GAIN STABILITY 0.25DB/24HRS: MAXOPERATING HUMIDITY 95PCT


Back to Top
Back to Top