5996-01-572-4248

AMPLIFIER,ELECTRONIC CONTROL


5996-01-572-4248 (5996015724248, 015724248)
Part Number (1 listing): 44PA1-1A1
Summary

FSG 59 / FSC 5996

DEMIL: D

DEMIL INT: 1

HMIC: N

Date Created: 11 Mar 2009

MSDS: None

Hazmat: None

Request a Quote


;



MASTER CROSS REFERENCE LIST (MCRL) | NSN 5996-01-572-4248 Submit RFQ
Manufacturer Part NumberRNCCRNVCManufacturer NameCAGE
44PA1-1A13 - Design Control Reference2 - Production ItemNORTH ATLANTIC INDUSTRIES, INC.  0VGU1    CAGE 0VGU1  
Code Definitions

3 - Design Control Reference

Reference Number Category Code (DRN_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2 - Production Item

Reference Number Variation Code (DRN_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.


FLIS - SEG A - IDENTIFICATION | NSN 5996-01-572-4248 Submit RFQ
FSGFSCNIINFIIGINCCRITICALITYTYPE OF ITEMMRCDEMILHMICEDCPMICADPECDATE CREATED
595996015724248A3220000096X43DNAA011 Mar 2009
Code Definitions

59

Federal Supply Group (FSG_3994/FSC_WI_FSG_3996)


Electrical and Electronic Equipment Components

5996

Federal Supply Class (FSC_3994/FSC_WI_FSC_3996)


Amplifiers

015724248

National Item Identification Number (NCB_CD_4130/I_I_NBR_4131)


NSN 5996-01-572-4248

A32200

Federal Item Identification Guide (FIIG_4065)

00096

Item Naming Code (INC_4080)

11 Mar 2009

NIIN Assignment Date (DT_NIIN_ASGMT_2180)

X

Item Criticality (CRITL_CD_FIIG_3843)


The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

4

Type of Item Identification (TYP_II_4820)


Partial Descriptive Item Identification (Type 1 Concept)

3

Reference / Partial Descriptive Method Reason Code (RPDMRC_4765)


An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.

D

Demilitarization Code (DEMIL_CD_0167)


MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)

N

Hazardous Material Indicator Code (HMIC_0865)


Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.

A

Electrostatic Discharge Code (ESD_EMI_CD_2043)


No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.

A

Precious Metals Indicator Code (PMIC_0802)


Item does not contain Precious Metal.

0

ADPE Identification Code (ADPEC_0801)


Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)


FLIS - SEG B - MOE RULE DATA | NSN 5996-01-572-4248 Submit RFQ
MOE RuleFormer MOEAMCAMSCNIMSCIMCIMC ActivityAACDSORCollaboratorsReceiversEffective Date
ZF011 Mar 2009
Code Definitions

FLIS - SEG C - REFERENCE NUMBER | NSN 5996-01-572-4248 Submit RFQ
RNFCRNCCRNVCDACRNAACRNSCRNJCSADCMSDSHCCReference NumberCAGE
43249ZD44PA1-1A1  0VGU1   CAGE/0VGU1
Code Definitions

4

Reference Number Format Code (RNFC_2920)


Number is totally in-the-clear (without modification) as originally configured by the manufacturer, design control activity, or supplier.

3

Reference Number Category Code (RNCC_2910)


Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.

2

Reference Number Variation Code (RNVC_4780)


A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.

4

Document Availability Code (DAC_2640)


The reference number is represented by technical documentation other than a drawing and the documentation was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number; however, the RNAAC cannot furnish the technical documentation.

9Z

Reference Number Action Activity Code (RNAAC_2900)


DLIS-K, Battle Creek, MI 49037-3084

D

Reference Number Status Code (RNSC_2923)


Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.


FLIS - SEG E - ITEM STANDARDIZATION DATA | NSN 5996-01-572-4248 Submit RFQ
ISCOriginatorNIIN StatusReplaced / Replacement ISCReplaced / Replacement OriginatorReplacement NIIN StatusReplacement DateReplaced / Replacement NSNDecision Date
597011 Mar 2009
Code Definitions

5

Item Standardization Code (ISC_2650)


An item authorized for procurement that has not yet been subject to item standardization.

97

Originator of Standardization Decision (ORG_STDZN_DEC_9325)


DLIS-LFF, Battle Creek, MI 49037-3084

0

NIIN Status Code (NIIN_STAT_CD_2670)


Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.

11 Mar 2009

Standardization Decision Date (DT_STDZN_DEC_2300)


FLIS - SEG G - FREIGHT DATA | NSN 5996-01-572-4248 Submit RFQ
IntegrityOriginatingHMCLCLWCCTCCSHCADCACCASHLTLNMFCNMFC Sub ItemUFCFreight DescriptionRail Variance
96
Code Definitions

96

Originating Activity Code (ORIG_ACTY_CD_4210)


DLIS-LFF, Battle Creek, MI 49037-3084

Rail Variance

Rail Variance (RAIL_VARI_CD_4760)


No Variation. NMFC and UFCC Match.


FLIS - SEG M/V - CHARACTERISTICS DATA | NSN 5996-01-572-4248 Submit RFQ
MRCDecoded RequirementClear Text Reply
AGTABasic Shape StyleRECTANGULAR OR SQUARE
BJBPConnection Type And LocationCONNECTOR, PLUG RIGHT SIDE
BJBWConnection Contact Type And Quantity1 CONNECTOR, PLUG EXTERNAL
AQZFControl TypeREMOTE
ADZCEnvironmental ProtectionELECTRICALLY INSULATED AND SHOCK RESISTANT
BHTBFrequency Per Channel400.0 HERTZ NOMINAL OUTPUT CHANNEL
BHSXCircuit Construction TypeSOLID STATE
BJBMMaximum Continuous Operating Time In Hours45000.0
ALBMOperating Control MethodAUTOMATIC
AFGAOperating Temp Range-40.0/+71.0 DEG CELSIUS
BHTNImpedance Rating Per Channel190.000 OHMS INPUT CHANNEL
AKNAInclosure TypeENCASED
AFBHIndividual Section Quantity1
BJBNShock Pulse Duration Time11.0 MILLISECONDS
AFDPShock Resistance Rating In Gravitational Units50.0
BHTKSignal Voltage Rating Per Channel30.000 VOLTS NOMINAL OUTPUT
ABKWOverall Height2.480 INCHES NOMINAL
ABHPOverall Length7.400 INCHES NOMINAL
ABMKOverall Width5.090 INCHES NOMINAL
CXCYPart Name Assigned By Controlling Agency30 VA SYNCHRO BOOSTER AMPLIFIER
FEATSpecial FeaturesMILITARY GRADE STAND-ALONE UNIT; STANDARD ENCLOSURE OUTPUT ALWAYS ON, DOES NOT REQUIRE +5 VDC; 90 DEGREES VL-L SYNCHRO INPUT; BUILT-IN-TEST TO MONITOR OVER TEMP AND CURRENT; ACCEPTS HIGH VOLTAGE SYNCHRO INPUT OR LOW VOLTAGE RESOLVER INPUT; DRIVES MOST EXISTING 60 OR 400 HZ TRANSFORMERS OR TORQUE RECEIVERS


Back to Top