| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 101072383 | 3 - Design Control Reference | 2 - Production Item | EATON CORPORATION | 31795 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5998 | 012822992 | A511K0 | 61638 | Y | 1 | D | N | B | A | 0 | 13 Jul 1988 |
Electrical and Electronic Assemblies, Boards, Cards, and Associated Hardware
The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Represents items with ESD sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| F2HD | FUU4 | 0 | 0 | 9 | E | 99 | 1 Sep 2013 | |||||||||||||||||||||||
| N2H4 | 0 | 0 | U | E | 99 | GG | KF | 1 Sep 2013 | ||||||||||||||||||||||
Not Established
Exception Item (Depot Maintenance Review Not Completed). This code identifies items wherein assignment for depot repair has not been established. PICA responsibilities are limited to single submitter of cataloging data, acquisition and disposal authority. Upon completion of depot maintenance review, and assignment for depot repair is made, code 9 items will be reassigned to code 1, 2, 3, 5, 6 or 8. The SICA CMD will reflect the Source of Supply or SOS Modifiers compatible with the SICA managing activities. The PICA will not be entered in the DAAS IMM field.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Unassigned. MISMO review not completed. Current depot repair arrangements remain in effect.
Depot source of repair has not been assigned. This is a temporary code that will be used only until a DSOR is assigned as specified in joint Service regulation AMC-R 750û10, OPNAVINST 4790.14A AFI 21û133(I), MCO P4790.10B, DLAD 4151.16, Joint Depot Maintenance Program, 31 March 1999.
Naval Inventory Control Point, Philadelphia, PA 19111û5098
Navy Material Transportation Office, Naval Station Norfolk, VA 23511
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 6 | TX | 0 | 16 Jul 1988 |
An item authorized for procurement that is in a specific Federal Supply Class (FSC) or item name grouping consisting primarily of items which are one-of-a-kind; therefore, little or no potential exists for elimination of items through formal item reduction studies.
Defense Supply Center Columbus, Columbus, OH 43218
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| TA | M | 738 | 3 | 9 | A | H | Z | W | 061045 | Z | 34580 | BOARDS-PRINTED-CIRCUIT-ELEC |
Sacramento Air Logistics Center, McClellan AFB, CA 95652-5609
85
Computing Equipment, Computer Components, and Circuit Cards
Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).
No QUP
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
1
Department of the Navy
| Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
|---|---|---|---|---|---|---|---|---|---|---|---|
| P | P | 41 | 1 | 000 | 3.0 lbs | 13.5in x 13.5in x 4in | 0.421 cu ft | 1.0 lbs | 10in x 10in x 1in |
| Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 00 | X | NS | 00 | B | 00 | F | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Watervaporproof bag, sealed
Any suitable process that is not injurious to the item.
No requirement
As required to protect the item or elements of the package
PPP-B-1672, Type II, folding convoluted cushioning in reusable box.
No requirement.
Unit container provides level B packing protection.
No special marking
Packing is not required: the unit container shall also serve as the shipping container. Closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AGAV | End Item Identification | FAIRCHILD SATOPERCNTR |
| CBBL | Features Provided | ELECTROSTATIC SENSITIVE |
| CRTL | Criticality Code Justification | CBBL |