| Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
|---|---|---|---|---|---|
| 13593180 | 3 - Design Control Reference | 2 - Production Item | U S ARMY AVIATION AND MISSILE | 18876 | |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
| FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 59 | 5998 | 014953601 | A511K0 | 61638 | X | 1 | D | N | A | A | 0 | 13 Mar 2002 |
Electrical and Electronic Assemblies, Boards, Cards, and Associated Hardware
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
| MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ZA01 | 1 Nov 2004 | |||||||||||||||||||||||||||||
| A302 | A303 | 3 | P | A | J | LK | 1 Feb 2010 | |||||||||||||||||||||||
| ZN01 | 1 Nov 2010 | |||||||||||||||||||||||||||||
| ZF01 | 1 Dec 2010 | |||||||||||||||||||||||||||||
| NADD | 3 | P | 5 | J | LK | GT | 1 Mar 2013 | |||||||||||||||||||||||
| ZG01 | 1 Feb 2015 | |||||||||||||||||||||||||||||
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The rights to use the data needed to purchase this part from additional sources are not owned by the Government and cannot be purchased. Valid AMCs: 1, 2, 3, 4 and 5.
An activitiy within the Army is providing depot maintenance support.
Design Unstable: Items determined by technical decision during the provisioning cycle, during introduction into logistic systems, or at time of item management coding, to be highly subject to either: (A) Design change of the item itself, or (B) Replacement of the item itself through modification of the applicable next-higher assembly. These items will be reviewed for recording when an IM is notified that the item is used by another service/agency, when the design becomes stabilized, or when the item has been in operational use for two years. In all cases these shall be reviewed by IM for IMC change no longer than two years after the IMC J assignment.
Depot Reparable Component (Type II). This code identifies SICA managed depot reparable components assigned to another service which is responsible for the logistics functions of single submitter cataloger, acquisition and disposal authority, depot maintenance, and performs the wholesale stock, store, and issue functions and establishes, budgets, and funds the wholesale stock level requirement. Supply requirements will be submitted to the PICA on requisitions which are funded by a designated point within the SICA. Unserviceable SICA assets will normally be returned to the PICA for credit. The SICA will provide item/program data required by the PICA to meet the materiel support commitments. Normally, Military Interdepartmental Purchase Requests (MIPR) will not be requested by the PICA to support SICA NIMSC 5 requirements. The SICA CMD will reflect Source of Supply or SOS Modifiers compatible with the SICA managing activity. The PICA will not be entered in the DAAS IMM field.
Letterkenny Army Depot (LEAD), Chambersburg, PA
| RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 2 | 1 | ZZ | 13593180 | 18876 | | ||||||
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
USA
| ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
|---|---|---|---|---|---|---|---|---|
| 1 | 98 | 0 | 3 | 98 | 0 | 15 Apr 2004 | 5998014951140 | 15 Apr 2004 |
An item authorized for procurement as a result of a formal item reduction study and accepted as a replacement for one or more items not authorized for procurement. In addition, in generic relationships, a code 1 item is related to a code 2 item.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
An item which, as a result of a formal item reduction study, is accepted as not authorized for procurement.
| Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BD | 738 | Z | 9 | A | H | Z | W | 061045 | Z | 34580 | BOARDS-PRINTED-CIRCUIT-ELEC |
U.S. Army Aviation and Missile Command, Redstone Arsenal, AL 35898-5230
Computing Equipment, Computer Components, and Circuit Cards
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
| Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
|---|---|---|---|---|---|---|---|---|---|---|---|
| P | P | B | GX | 1 | 000 | 1.2 lbs | 6.3in x 5.3in x 3in | 0.058 cu ft | 0.4 lbs | 4.7in x 2.5in x 0.5in |
| Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 00 | K3 | LT | A | NS | 00 | B | 39 | Q | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Unheated General Purpose
Preserve by Method 41 as follows: Items subject to damage by electromagnetic and electrostatic field forces shall be initially wrapped in material conforming to MIL-PRF-81705, Type III, or bags conforming to MIL-DTL-117, Type II, Class H, Style 2, or cushioned in material conforming to A-A-3129, Type I, Grade B or PPP-C-795, Class 2 or PPP-C-1797, Type II, to prevent bag puncture, and unit packed in a heat-sealed bag conforming to MIL-DTL-117, Type I, Class F, Style 1. Reclosable cushioned pouches conforming to MIL-DTL-81997, Type I or II, may be used in lieu of initial wrap or cushioning. Lead or terminal configurations for all items shall be maintained as manufactured without causing loads or stresses capable of causing damage to the item. Materials used to maintain item position and lead or terminal configuration shall permit item removal without damage to the item. Electrostatic discharge (ESD) sensitive caution labels shall be applied in accordance with MIL-STD-129.
Any suitable process that is not injurious to the item.
No requirement
MIL-PRF-81705, Type III, Class 1, transparent, electrostatic protective, static shielding, barrier material or MIL-DTL-117, Type II, Class H, Style 2 bag
PPP-C-795, Class 2, antistatic cellular plastic film cushioning
1/4 inch thick
PPP-B-1672, Type II, folding convoluted cushioning in reusable box.
No requirement.
Unit container provides level B packing protection.
ESD sensitive electronic device requirements of MIL-STD-129 apply
Packing shall be accomplished in accordance with table C.II for the packing level specified. Closure sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
| MRC | Decoded Requirement | Clear Text Reply |
|---|---|---|
| AGAV | End Item Identification | HELLFIRE |