Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
7322993G001 | 3 - Design Control Reference | 2 - Production Item | LOCKHEED MARTIN CORPORATION | 03538 | ![]() |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
59 | 5999 | 003461949 | A32100 | 06373 | X | M | 3 | D | P | A | A | 0 | 12 Jan 1974 |
Miscellaneous Electrical and Electronic Components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Partial Descriptive - Reference Item Identification (Type 1A Concept)
An approved item name and FIIG exist but the item involved is so unique in design that it cannot be fully described in accordance with the FIIG.
MLI (SME) — Total destruction of item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DOD Demilitarization Program Office.)
Indicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N2H4 | 3 | H | P | E | HD | CN | 1 Apr 1991 | |||||||||||||||||||||||
ZW01 | 1 Nov 1998 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Total depot maintenance is being accomplished by commercial contract.
Reparables: Centrally managed recoverable items designated as reparable for the reasons that repair of unserviceable quantities of the items are considered by the inventory manager in satisfying requirements prior to or in conjunction with determining procurement quantities.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Contract, Contiguous United States (CONUS)
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 3 | 2 | 1 | HH | D | 7322993G001 | 03538 | ![]() |
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Navy ICP, Mechanicsburg, PA 17055-0788
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 98 | 0 | 1 Feb 1975 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HH | FF | 658 | Z | 2 | A | H | Y | P | 061300 | X | 34410 | CIRCUIT-BREAKER-SWITCH-NOI |
Navy ICP, Mechanicsburg, PA 17055-0788
Code FF denotes special factors or conditions in an item description which have an effect on the ratings or charges; therefore, the item description should be read carefully to ensure that such special factors or conditions can be included as a part of the bill of lading description.
Electical Appliances, Small
No special type of cargo code applicable
Classified
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Protected cargo, other than above, including sensitive cargo requiring hand-to-hand receipt and/or security precautions.
77.5
No Variation. NMFC and UFCC Match.
NAVICP-ERP, 700 Robbins Avenue, Philadelphia, PA 19111-5098
SERVICE/AGENCY-MANAGED (Service/Agency use only.) Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Non-Sensitive (SRC-N/A) — UNCLASSIFIED AA&E or Items assigned a Demilitarization Code other than A, B, Q or P for which another CIIC is inappropriate. (NOTE: The loss, theft, unlawful 011disposition, and/or recovery of an item with CIIC 7 will be investigated in accordance with DoD 4000.25-2-M and DoD 7200.14–R, Volume 12, Chapter7).
No QUP
ARMY: If condemned or uneconomically repairable, then dispose at intermediate level; COAST GUARD: Reparable item. Repair, condemnation, and disposal not authorized below intermediate (district) level; MARINE CORPS: Reparable item. When uneconomically reparable, condemn and dispose at fourth echelon level; NAVY: Depot Level Reparable
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
ARBR | Body Depth | 12.080 INCHES NOMINAL |
ADAQ | Body Length | 34.080 INCHES NOMINAL |
AAQL | Body Style | RECTANGULAR, BRACKETED |
ADAT | Body Width | 4.380 INCHES NOMINAL |
CCDN | Delay Time Variation Method | TAPPED |
AKPV | Mounting Facility Quantity | 2 AND 10 |
AZGM | Mounting Facility | FLANGE AND SLOT |
AFBH | Individual Section Quantity | 2 |
ANNQ | Material And Location | ALUMINUM ALLOY,QQ-A-250/8 5032-H32 OVERALL |
CCDS | Segment Delay Time | 1003.600 MICROSECONDS NOMINAL 2ND SECTION 13TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 106.800 MICROSECONDS NOMINAL 1ST SECTION 9TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 117.400 MICROSECONDS NOMINAL 1ST SECTION 10TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 1134.700 MICROSECONDS NOMINAL 2ND SECTION 14TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 124.600 MICROSECONDS NOMINAL 2ND SECTION 4TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 121.500 MICROSECONDS NOMINAL 1ST SECTION 11TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 13.700 MICROSECONDS NOMINAL 2ND SECTION 1ST SEGMENT ERR-100 |
CCDS | Segment Delay Time | 131.100 MICROSECONDS NOMINAL 1ST SECTION 12TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 182.800 MICROSECONDS NOMINAL 2ND SECTION 5TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 24.300 MICROSECONDS NOMINAL 1ST SECTION 1ST SEGMENT ERR-100 |
CCDQ | Section Delay Time | 13.700 MICROSECONDS MINIMUM 2ND SECTION ERR-100 AND 1134.700 MICROSECONDS MAXIMUM 2ND SECTION ERR-100 |
CCDQ | Section Delay Time | 24.300 MICROSECONDS MINIMUM 1ST SECTION ERR-100 AND 131.100 MICROSECONDS MAXIMUM 1ST SECTION ERR-100 |
CCDS | Segment Delay Time | 251.600 MICROSECONDS NOMINAL 2ND SECTION 6TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 336.500 MICROSECONDS NOMINAL 2ND SECTION 7TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 38.000 MICROSECONDS NOMINAL 1ST SECTION 2ND SEGMENT ERR-100 |
CCDS | Segment Delay Time | 38.000 MICROSECONDS NOMINAL 2ND SECTION 2ND SEGMENT ERR-100 |
CCDS | Segment Delay Time | 429.600 MICROSECONDS NOMINAL 2ND SECTION 8TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 48.600 MICROSECONDS NOMINAL 1ST SECTION 3RD SEGMENT ERR-100 |
CCDS | Segment Delay Time | 526.800 MICROSECONDS NOMINAL 2ND SECTION 9TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 58.200 MICROSECONDS NOMINAL 1ST SECTION 4TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 633.600 MICROSECONDS NOMINAL 2ND SECTION 10TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 68.800 MICROSECONDS NOMINAL 1ST SECTION 5TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 751.000 MICROSECONDS NOMINAL 2ND SECTION 11TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 76.000 MICROSECONDS NOMINAL 2ND SECTION 3RD SEGMENT ERR-100 |
CCDS | Segment Delay Time | 84.900 MICROSECONDS NOMINAL 1ST SECTION 6TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 872.500 MICROSECONDS NOMINAL 2ND SECTION 12TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 93.100 MICROSECONDS NOMINAL 1ST SECTION 7TH SEGMENT ERR-100 |
CCDS | Segment Delay Time | 97.200 MICROSECONDS NOMINAL 1ST SECTION 8TH SEGMENT ERR-100 |
CCDR | Segment Quantity Per Section | 12 1ST SECTION |
CCDR | Segment Quantity Per Section | 14 2ND SECTION |
BZWM | Signal Delay Method | LUMPED CONSTANT |
ABHP | Overall Length | 34.080 INCHES NOMINAL |
ANNR | Surface Treatment And Location | OXIDE FILM, MIL-C-5541 OVERALL |
CCFF | Terminal Type And Quantity | 2 TERMINAL BLOCK W/SCREWS |