Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
U-211821 | 3 - Design Control Reference | 2 - Production Item | TRANSICOIL LLC | 82686 | |
229-1030-020 | 5 - Replaced / Discontinued | 9 - No Longer Used | ROCKWELL COLLINS, INC. | 13499 | |
S11060 | 5 - Replaced / Discontinued | 9 - No Longer Used | MAGNETIC PERIPHERALS INC | 19333 | |
CR00132-670 | 5 - Replaced / Discontinued | 9 - No Longer Used | KEARFOTT CORPORATION | 88818 | |
S11060 | 5 - Replaced / Discontinued | 9 - No Longer Used | SL-MONTEVIDEO TECHNOLOGY, INC. | 54572 | |
2392-115-009 | 5 - Replaced / Discontinued | 9 - No Longer Used | MPC PRODUCTS CORPORATION | 19710 | |
115-009 | 5 - Replaced / Discontinued | 9 - No Longer Used | MPC PRODUCTS CORPORATION | 19710 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6105 | 000153509 | A271A0 | 19258 | X | 1 | A | N | U | 25 Apr 1967 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YJ01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZA01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZC01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZE01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZP01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZT01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Nov 1998 | |||||||||||||||||||||||||||||
FXGG | FXCX | 3 | C | Z | SX | 1 Feb 2005 | ||||||||||||||||||||||||
N9BG | N9GD | 3 | C | Z | GH | GT | HD | 1 Feb 2005 | ||||||||||||||||||||||
ZU01 | 1 Feb 2007 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
This part requires engineering source approval by the design control activity in order to maintain the quality of the part. An alternate source must qualify in accordance with the design control activity's procedures, as approved by the cognizant Government engineering activity. Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 2 | A | CX | U-211821 | 82686 | |||||||
3 | 5 | 9 | 5 | SE | D | CR00132-670 | 88818 | |||||
3 | 5 | 9 | 1 | SE | D | 229-1030-020 | 13499 | |||||
1 | 5 | 9 | 5 | SE | B | S11060 | 19333 | |||||
1 | 5 | 9 | 5 | SE | B | 115-009 | 19710 | |||||
5 | 9 | A | CX | 2392-115-009 | 19710 | |||||||
5 | 9 | A | CX | S11060 | 54572 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by an engineering drawing and the drawing is available for unlimited use. The drawing will be furnished by the activity identified by the RNAAC upon request.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Secondary Reference. Any additional number, other than a primary number (codes 1,2,3,4) informative reference (code 6) or vendor item drawing reference (code 7) assigned to an item of production or supply by a commercial or Government organization, which represents the same item of production or supply to which the National Stock Number (NSN) was assigned. The reference number may have had an RNCC of 1, 2, 3, 4 or 7 but has since been replaced in the item-of-supply concept of the NSN by another primary number.
A specification, standard, or other reference number which is superseded, canceled, obsolete or discontinued and is coded Reference Number Category Code (RNCC) 5; a reference number for information only coded RNCC 6; or a reference number coded RNCC D.
The reference number is represented by a drawing, but the drawing was not available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number.
San Antonio Air Logistics Center, Kelly AFB, TX 78241-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Manufacturer and/or reference number are not authorized for procurement. NOTE: This code may be used for obsolete or informative reference numbers only.
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
5 | 96 | 0 | 1 Jan 1996 |
An item authorized for procurement that has not yet been subject to item standardization.
DLIS-LFF, Battle Creek, MI 49037-3084
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AX | 593 | Z | 9 | A | H | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI |
Defense Supply Center Columbus, Columbus, OH 43216-5000
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | AAA | 0.3 lbs | 0.018 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | GB | X | D3 | 00 | E | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
MIL-PRF-121, greaseproof, waterproof barrier
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CWGQ | Connection Type And Voltage Rating In Volts | 115.0 LINE TO NEUTRAL SINGLE INPUT |
BFMF | Cooling Method | NONVENTILATED |
BFMJ | Control Field Current Rating In Amps | 0.415 AND 0.204 |
BFMK | Control Field Impedance Rating In Ohms | 48.0 AND 191.0 |
BKPS | Control Field Voltage Type And Rating In Volts | 18.0 AC AND 36.0 AC |
BFML | Control Field Winding Type | TWO WINDINGS, SERIES CONNECTED OR TWO WINDINGS, PARALLEL CONNECTED |
BKPB | Current Rating Method | NO LOAD |
CWGL | Current Rating In Amps | 0.057 SINGLE INPUT |
ACDC | Current Type | AC INPUT |
CBBL | Features Provided | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
FREQ | Frequency In Hertz | 400.0 INPUT |
BFMS | Full Tooth Length | 0.3130 INCHES NOMINAL SINGLE END |
AKAE | Maximum Operating Altitude Rating | 10000.0 FEET |
AXHR | Mounting Facility Type And Quantity | 1 CLAMP COLLAR |
AXGY | Mounting Method | CLAMP RING |
AAJU | Overall Length | 1.437 INCHES |
ANPZ | Inclosure Feature | TOTALLY INCLOSED |
BKPQ | Inclosure Specification | COMMERCIAL |
CWCS | Length Of Shaft From Housing | 0.313 INCHES SINGLE END |
CWFX | Rotor Speed Rating In Rpm | 6500.0 LOW NO LOAD |
ABWV | Shaft Diameter | 0.125 INCHES MINIMUM SINGLE END AND 0.126 INCHES MAXIMUM SINGLE END |
CWHZ | Shaft End Characteristic | A17 SINGLE STYLE SINGLE END |
AAJT | Overall Height | 1.062 INCHES |
AAJV | Overall Width | 1.062 INCHES |
FAAZ | Phase | TWO INPUT |
AJLA | Teeth Quantity | 13 SINGLE END |
CWDY | Temp Rating | -54.0 OPERATING DEG CELSIUS AND 170.0 OPERATING DEG CELSIUS |
TTQY | Terminal Type And Quantity | 6 WIRE LEAD |
BKPH | Torque Rating And Type | 0.7 INCH-OUNCES STALLED |