Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
X2309-5 | 3 - Design Control Reference | 2 - Production Item | BOWMAR, LLC | 99479 | |
576R869H05 | 7 - Vendor Item Drawing Reference | 2 - Production Item | NORTHROP GRUMMAN SYSTEMS CORPORATION | 97942 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6105 | 000595356 | A271A0 | 19258 | X | 1 | B | N | U | 8 Jun 1967 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive Item Identification
MLI (Non-Significant Military Equipment – Non-SME) — Demilitarization not required — Trade Security Controls (TSCs) required at disposition.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Precious Metal Content is unknown.
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ZH01 | 1 Apr 1991 | |||||||||||||||||||||||||||||
ZW01 | 1 Dec 1995 | |||||||||||||||||||||||||||||
FXGG | FXCX | 1 | G | Z | SX | 1 Feb 2005 | ||||||||||||||||||||||||
N9BG | N9GD | 1 | G | Z | KE | KE | 1 Feb 2005 | |||||||||||||||||||||||
ZU01 | 1 Feb 2007 |
Suitable for competitive acquisition. Potential sources shall include dealers/distributors. If sources are limited to the prime contractor and a subcontractor, a competitive code shall not be assigned unless both sources are expected to compete independently for contracts for the part.
The Government has unlimited rights to the technical data, and the data package is complete. Valid AMCs: 1 and 2.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Oklahoma City Air Logistics Center, Tinker AFB, OK 73145-3043
Naval ICP, Philadelphia, PA 19111
Naval ICP, Philadelphia, PA 19111
RNFC | RNCC | RNVC | DAC | RNAAC | RNSC | RNJC | SADC | MSDS | HCC | Reference Number | CAGE | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 3 | 2 | 1 | CX | D | X2309-5 | 99479 | |||||
3 | 7 | 2 | 1 | AX | D | 576R869H05 | 97942 |
Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9.Number is formatted as configured on the originating document with the exception of the modification required in volume 2, chapter 2.9 .
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
The reference number is represented by a drawing and the drawing was available to the RNAAC, who may or may not be the submitting activity, at the time of submission of the reference number. The RNAAC will furnish the drawing upon request.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Procurement authority of the manufacturer and reference number have not yet been checked. NOTE: This code is to be allocated to reference numbers still requiring checks on procurement authority.
Number format is unknown. (Coded RNFC 3 by the Defense Logistics Information Service upon implementation of FLIS.)
Vendor Item Drawing Reference (formerly Specification Control Reference). The number assigned by a design activity to a drawing that is not item-identifying, but which delineates existing commercial or vendor-developed items meeting all engineering and test requirements specified, without imposing additional test/engineering requirements not normally provided by the vendor(s). Includes only those drawings which meet the definition for Vendor Item Drawing in MIL-STD 100. Vendor Item Drawing References are administrative control numbers and shall not be used as part identification numbers.
Defense Supply Center Columbus, Columbus, OH 43216-5000
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
2 | CX | 0 | 25 Feb 1972 |
An item authorized for procurement which has been included in an item reduction study and which initially does not replace an item not authorized for procurement. In addition, in generic relationships, a code 2 item is related to a code 1 item.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AX | 593 | Z | 9 | A | H | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI |
Defense Supply Center Columbus, Columbus, OH 43216-5000
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Unclassified
1
AIR FORCE ERRC XB3: Stock Fund (Except Munitions); DLA: This item has been reviewed and a determination made that the item cannot or should not be restored to a serviceable condition from an unserviceable condition; NAVY: 1I cog not stocked print on demand flat forms
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Air Force
Department of the Navy
Defense Logistics Agency
Source | PICA / SICA | Packaging Category | Storage | Preservation | Clean/Dry | INT Qty | Unit Weight | Unit Size | Unit Pack Cube | Item Weight | Item Dims |
---|---|---|---|---|---|---|---|---|---|---|---|
P | P | 10 | 1 | AAA | 0.7 lbs | 0.052 cu ft |
Preservation Material | Wrapping Material | Cushioning / Dunnage | Cushioning Thickness | Unit Container | Intermediate Container | Unit Container Level | Special Marking | Level A Packing | Level B Packing | Minimal Packing | Optional Procedure |
---|---|---|---|---|---|---|---|---|---|---|---|
00 | X | D3 | 00 | E | Q | O |
Primary Inventory Control Activity (PICA)
Primary Inventory Control Activity (PICA)
Physical protection
Any suitable process that is not injurious to the item.
No requirement
As required to protect the item or elements of the package
PPP-B-566, PPP-B-676, or ASTM-D5118, folding, setup or fiberboard box.
No special marking
Packing shall be accomplished to meet the performance test requirements of ASTMD4169, Distribution Cycle 18, Assurance Level 1.
Packing shall be accomplished in accordance with table C-II for the packing level specified. Closure sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used. However, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. Equal or better protection shall be given the item and there shall be no increase in the package cost.
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
CWGQ | Connection Type And Voltage Rating In Volts | 115.0 LINE TO NEUTRAL SINGLE INPUT |
BFMF | Cooling Method | SELF-VENTILATED |
BFMJ | Control Field Current Rating In Amps | 0.178 AND 0.356 |
BFMK | Control Field Impedance Rating In Ohms | 151.0 AND 38.0 |
BKPS | Control Field Voltage Type And Rating In Volts | 40.0 AC AND 20.0 AC |
BFML | Control Field Winding Type | TWO WINDINGS, SERIES CONNECTED OR TWO WINDINGS, PARALLEL CONNECTED |
BKPB | Current Rating Method | LOAD |
CWGL | Current Rating In Amps | 0.062 SINGLE INPUT |
ACDC | Current Type | AC INPUT |
CBBL | Features Provided | ELECTRIC NOISE SUPPRESSOR AND HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |
FREQ | Frequency In Hertz | 400.0 INPUT |
AXHR | Mounting Facility Type And Quantity | 1 CLAMP COLLAR |
AXGY | Mounting Method | CLAMP RING |
AAJU | Overall Length | 2.931 INCHES |
ANPZ | Inclosure Feature | OPEN PROTECTED |
BKPQ | Inclosure Specification | COMMERCIAL |
CWCS | Length Of Shaft From Housing | 0.275 INCHES SINGLE END |
CWFX | Rotor Speed Rating In Rpm | 52.0 SINGLE NO LOAD |
ABWV | Shaft Diameter | 0.1874 INCHES NOMINAL SINGLE END |
CWHZ | Shaft End Characteristic | A1 SINGLE STYLE SINGLE END |
AAJT | Overall Height | 1.437 INCHES |
AAJV | Overall Width | 1.437 INCHES |
FAAZ | Phase | SINGLE INPUT |
CWDY | Temp Rating | -65.0 OPERATING DEG CELSIUS AND 125.0 OPERATING DEG CELSIUS |
TTQY | Terminal Type And Quantity | 6 SCREW |
BKPH | Torque Rating And Type | 0.6 INCH-OUNCES STALLED |