Manufacturer Part Number | RNCC | RNVC | Manufacturer Name | CAGE | |
---|---|---|---|---|---|
1JH2960 | 3 - Design Control Reference | 2 - Production Item | WESTINGHOUSE ELECTRIC CORP | 79500 | |
MILM17060 | 4 - Non-Definitive Specification or Standard Document | 1 - Incomplete Part Number | MILITARY SPECIFICATIONS | 81349 |
Design Control Reference. The primary number used to identify an item of production or a range of items of production, by the manufacturer (individual, company, firm, corporation, or Government activity) which controls the design, characteristics, and production of the item by means of its engineering drawings, specifications and inspection requirements.
Non-Definitive U.S. Government Specification or Standard Reference. Any Government specification or standard reference other than those indicated in code 2 as definitive references. This code shall be used for non-definitive Government specifications and standard references and non-definitive part numbers, type designators, and style numbers included therein which are coded with RNVC 1.
A design control or other reference number that is an item-identifying number for an item of production, or a source control reference or a specification or standard part, type, or similar reference number that is an item-identifying number for an item of supply.
A design control or other reference number that does NOT identify an item of production without the use of additional information, or a specific part, type, or similar reference number does NOT identify or item of supply without the use of additional information.
FSG | FSC | NIIN | FIIG | INC | CRITICALITY | TYPE OF ITEM | MRC | DEMIL | HMIC | EDC | PMIC | ADPEC | DATE CREATED |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
61 | 6105 | 000902400 | A271A0 | 00530 | X | K | A | N | A | 0 | 1 Jan 1963 |
Electric Wire, and Power and Distribution Equipment
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Full Descriptive - Reference Item Identification
Non-MLI/ Non-SLI — Demilitarization not required.
Indicates there is no data in the HMIRS and the NSN is in a FSC not generally suspected of containing hazardous materials.
Item does not contain Precious Metal.
Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
MOE Rule | Former MOE | AMC | AMSC | NIMSC | IMC | IMC Activity | AAC | DSOR | Collaborators | Receivers | Effective Date | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N9BG | N9GD | 3 | H | Z | HD | HD | 1 Feb 2005 |
Acquire directly from the actual manufacturer, whether or not the prime contractor is the actual manufacturer.
The Government physically does not have in its possession sufficient, accurate, or legible data to purchase this part from other than current source(s). (NOTE: This code is applicable only to parts under immediate buy requirements and only as long as the deficiency is under review for resolution and appropriate recoding.) Valid AMCs: 1, 2, 3, 4 and 5.
Integrated Management: Relinquishment of Service management of an item in designated commodity oriented Federal Supply Classes to the IMM (FSC manager) for management.
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
Naval Inventory Control Point, Mechanicsburg, PA 17055-0788
ISC | Originator | NIIN Status | Replaced / Replacement ISC | Replaced / Replacement Originator | Replacement NIIN Status | Replacement Date | Replaced / Replacement NSN | Decision Date |
---|---|---|---|---|---|---|---|---|
C | CX | 0 | 20 Dec 1972 |
An item authorized for procurement that has been included in an item reduction study but an intelligent decision could not be made due to lack of sufficient technical data.
Defense Supply Center Richmond, Richmond, VA 23297-5000
Item is active. File data coded KFD is forwarded. if this KFD data represents your item of supply, submit, if applicable, an LAD, LAU, or LCU transaction. Otherwise, use the National Stock Number (NSN) in your supply system.
Integrity | Originating | HMC | LCL | WCC | TCC | SHC | ADC | ACC | ASH | LTL | NMFC | NMFC Sub Item | UFC | Freight Description | Rail Variance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
593 | Z | 9 | A | H | Z | W | 062120 | Z | 34760 | GENERATORS-MOTORS-PARTS-NOI |
Motors and Parts, (machinery and parts), (less than 35 feet)
No special type of cargo code applicable
No special handling required
Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
No special handling required.
Variable Rating
No Variation. NMFC and UFCC Match.
Defense Logistics Agency, Enterprise Business Systems
TERMINAL ITEM (NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Unclassified
1
Each - A numeric quantity of one item of supply. Do not use if a more specific term applies, such as kit, set, assortment, assembly, group, sheet, plate, strip or length.
TYPE I or TYPE II (Non-Deteriorative/No Shelf-Life) - An individual item of supply which is determined through an evaluation of technical test data and/or actual experience to be an item with a definite non-extendible period of shelf-life OR An individual item of supply having an assigned shelf-life time period that may be extended after completion of inspection/test/restorative action.
Department of the Navy
Defense Logistics Agency
MRC | Decoded Requirement | Clear Text Reply |
---|---|---|
AKPS | Duty Cycle | INTERMITTENT |
BYDT | Bearing Type | ANNULAR BALL |
CWGQ | Connection Type And Voltage Rating In Volts | 440.0 LINE TO NEUTRAL SINGLE INPUT |
BFMF | Cooling Method | SELF-VENTILATED |
CWGL | Current Rating In Amps | 50.000 SINGLE INPUT |
BKPB | Current Rating Method | LOAD |
CBBL | Features Provided | HORIZONTAL MOUNTING POSITION |
CNMM | Frame Size Designation | 405 |
FREQ | Frequency In Hertz | 60.0 INPUT |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
AXGY | Mounting Method | FIXED BASE |
CWDT | Nominal Center To Center Distance Between Mounting Facilities Parallel To Length | 13.750 INCHES |
CWFY | Nominal Center To Center Distance Between Mounting Facilities Parallel To Width | 16.000 INCHES |
AAJU | Overall Length | 28.500 INCHES |
ANPZ | Inclosure Feature | DRIPPROOF PROTECTED-15 DEG |
BKPQ | Inclosure Specification | MIL-STD-108 |
AFYS | Keyway Length | 1.6250 INCHES NOMINAL SINGLE END |
ABRR | Keyway Width | 0.5000 INCHES NOMINAL SINGLE END |
BFMR | Keyway Center To Shaft End Distance | 0.9380 INCHES NOMINAL SINGLE END |
ABRV | Keyway Depth | 0.2500 INCHES NOMINAL SINGLE END |
CWCS | Length Of Shaft From Housing | 2.250 INCHES SINGLE END |
CNXS | Power Rating | 40.0000 HORSEPOWER OUTPUT |
CWFX | Rotor Speed Rating In Rpm | 1175.0 SINGLE NO LOAD AND 1200.0 SINGLE FULL LOAD |
CWDM | Shaft Center To Mounting Surface Distance | 10.000 INCHES SINGLE END |
ABWV | Shaft Diameter | 2.1245 INCHES NOMINAL SINGLE END |
CWHZ | Shaft End Characteristic | A10 SINGLE STYLE SINGLE END |
AKCT | Shaft Rotation Direction | CLOCKWISE SINGLE END OR COUNTERCLOCKWISE SINGLE END |
AAJT | Overall Height | 23.125 INCHES |
AAJV | Overall Width | 22.906 INCHES |
FAAZ | Phase | THREE INPUT |
AXCP | Winding Type | INDUCTION-SQUIRREL CAGE |
ANTN | Specific Use | CARGO HOIST HYDRAULIC PUMP |
CWDY | Temp Rating | 40.0 OPERATING DEG CELSIUS |
TTQY | Terminal Type And Quantity | 3 WIRE LEAD |
BFLT | Time Interval | 30.0 MINUTES MAXIMUM ON |